background image

 

 

SETTING RANGE 

 

MSUB18-I 

Page 9 / 20 

 

With 7 to 12 GEOM12  

 

For very long throw application, with flown or stacked MSUB18, recommended MSUB18 cardioid mode, 

crossover MSUB18 95 Hz and 12 GEOM12 crossover 75 Hz for the maximum impact. 

 

 

 

Ground Stack Sub design 

 

Содержание MSUB18 Series

Страница 1: ...DP2820 01 DI MSUB18 I User Manual ...

Страница 2: ... 11 ARRAY EQ____________________________________________________________________________ 13 MAINTENANCE ________________________________________________________________________ 14 TECHNICAL SPECIFICATIONS ___________________________________________________________ 16 USER NOTES _________________________________________________________________________ 17 EU Conformity declaration We NEXO SA ZA DU P...

Страница 3: ... accidentally If the system is used on a tripod please ensure the tripod s specifications are adapted and that it s height does not exceed 1 40m 55 Do not move the tripod with the system in position Connection and Powering Precautions Unplug connected cables before moving the system Power off the system before connecting the system When switching on the installation the amplifier must be powered l...

Страница 4: ...cked cluster Versions MSUB18 I for fix applications Black MSUB18 PW for fix applications White Connectors 2 fast connectors in front and back Seal your connections for an outdoor use with the kit provided Red Black MSUB18 I Sealing You can find 2 locations to wire MSUB18 I Choose how you wire the MSUB18 I and apply the followings procedures Unused side Put the heat shrink cap on the cable Use a ho...

Страница 5: ...it with a clamp Repeat for the second connector Attach them together to the rigging part Sheaths upwards Guide the cable through the entry up and or down Amplification The MSUB18 must be used with a NEXO processor to handle EQ phase alignment crossover and excursion thermal protection for the system loudspeakers The following table shows the number of MSUB18 subwoofers usable with each solution NX...

Страница 6: ... 60 75 85 95 or 120 Hz Omnidirectional Monitor setup with low pass at 60 75 or 85 Hz CARDIO setups For a directional use cardioid of subwoofers require at least two subwoofers and two channels of amplifier Cardioid back and front setups with low pass at 65 75 85 95 or 120 Hz Setup FR Front for the subwoofer pointed at the audience Setup BA Back for the subwoofer turned around The ideal ratio for a...

Страница 7: ...ency 85 Hz is recommended 85 Hz also for GEOM12 For stack configuration using MSUB18 in OMNI or CARDIO mode with 1 Back and 2 Front ang GEOM12 on top of them crossover 85 Hz is recommended 85 Hz also for GEOM12 A small overlap could have impact if needed for example MSUB18 120 Hz and GEOM12 75 Hz ...

Страница 8: ... Page 8 20 MSUB18 I With 4 to 6 GEOM12 For long throw application crossover 95 Hz is recommended OMNI mode For long throw stacking application up to 6 GEOM12 crossover 85 Hz is recommended on MSUB18 also for GEOM12 ...

Страница 9: ... Page 9 20 With 7 to 12 GEOM12 For very long throw application with flown or stacked MSUB18 recommended MSUB18 cardioid mode crossover MSUB18 95 Hz and 12 GEOM12 crossover 75 Hz for the maximum impact Ground Stack Sub design ...

Страница 10: ...MSUB18 RIGGING Page 10 20 MSUB18 I MSUB18 RIGGING Open the 4 bumpers Tx30 Insert the axis positionning the pin and secure by bending the legs ...

Страница 11: ...ll MSUB18 accessories have been designed so that cabinet are arrayed vertically VNI BUMPM12 VNT BUMPM12 Rated for a maximum of 12 GEOM12 or 8 MSUB18 or a combination with a maximum of 4 MSUB18 and 6 GEOM12 Flown on 2 rigging points with retractable rings Usable with VNT EXBARM12 for extra tilt angle and flown on one or two rigging points Ground stack assembly alone or with VNT GSTKM10M12S VNT GSTK...

Страница 12: ...MSUB18 ACCESSORIES Page 12 20 MSUB18 I VNT GSTKM10M12S VNT GSTKM10M12L VNT MNSTKM12 Rated for a maximum of 3 GEOM12 on the top of MSUB18 ...

Страница 13: ...ARRAY EQ MSUB18 I Page 13 20 ARRAY EQ The ArrayEQ allows to adjust the system frequency response in its lower range see curves below with different ArrayEq values ...

Страница 14: ...r Remove 12 screws TX25 on the side top and below to remove the grille 18 Driver Remove 8 screws Tx25 to remove the driver If you remove the side rigging and untighten the cable gland you have 2 windows to access 2 screws not mandatory To remove the driver pull and swing it towards you Red Black ...

Страница 15: ...5LEXSUB18 IPW Lexan MSUB18 I white 4 4 05PT60 Feet 60 with screw 5 1 05MSUB18 UAI Complete grille Installation Black with fasteners 1 05MSUB18 UAIPW Complete grille Installation White with fasteners 6 1 05HP18SW 4 18 Driver with screws 1 05HP18SW 4 RK Recone kit HP18SW 4 with screws 7 4 05VAX8 30 18 5 Clevis axis 8x30x18 5 Split Pin Ø3 2x20 x4 8 4 05VGOUF3 2X20 Split Pin Ø3 2x20 x10 9 2 05CNX222 4...

Страница 16: ...peak Crossover Frequency 32 65 32 75 32 85 32 95 32 120 Hz Nominal Impedance 4Ω Recommended Amplification 2000 W per cabinet SPECIFICATIONS Model MSUB18 I Components 1x 18 4 Ohms Long excursion Neodymium driver Material Baltic birch plywood Finish Black or white structural paint Front finish Steel front grille Back mesh Fittings 8x Side handles Connectors 2x Cable gland with 2 cores cables Weight ...

Страница 17: ...USER NOTES MSUB18 I Page 17 20 USER NOTES ...

Страница 18: ...USER NOTES Page 18 20 MSUB18 I ...

Страница 19: ...USER NOTES MSUB18 I Page 19 20 ...

Страница 20: ...USER NOTES Page 20 20 MSUB18 I NEXO S A Parc d activité de la Dame Jeanne F 60128 PLAILLY Tel 33 3 44 99 00 70 Fax 33 3 44 99 00 30 E mail info nexo fr nexo sa com ...

Отзывы: