SETTING RANGE
Page 6 / 20
MSUB18-I
SETTING
RANGE
Please consult nexo-sa.com for NEXO TD Controllers firmware information.
There are two setting ranges for surrounding speaker MSUB18:
« OMNI » setups; For a traditional use of the subwoofer in omnidirectional radiation (require at least one subwoofer and a
channel of amplifier).
•
Omnidirectional Main setup, with low-pass at 50, 60, 75, 85, 95 or 120 Hz.
•
Omnidirectional Monitor setup, with low-pass at 60, 75 or 85 Hz.
« CARDIO » setups; For a directional use (cardioid) of subwoofers (require at least two subwoofers and two channels of
amplifier):
•
Cardioid back and front setups, with low-pass at 65, 75, 85, 95 or 120 Hz.
-
Setup « FR » (Front) for the subwoofer pointed at the audience.
-
Setup « BA » (Back) for the subwoofer turned around.
•
The ideal ratio for a directional use is 2 x MSUB18 in CARDIO FRONT mode on top of 1x Reversed MSUB18 in
CARDIO BACK mode. From 1:1 to 4:1 ratio can be used
OMNI Assembly
CARDIO Assembly