background image

 

 

TECHNICAL

 

SPECIFICATIONS

 

 

MSUB12 

Page 15 / 20 

 

TECHNICAL

 

SPECIFICATIONS

 

 

MSUB12 WITH NEXO ELECTRONICS 

Frequency range (±6dB) 

55Hz 

– 150Hz 

Sensibility (1W / 1m) 

102dB SPL Nominal 

Peak SPL Level (1m) 

130 dB 

Operating voltage 

35 Vrms 

Crossover Frequency  

55-85; 55-120; 55-150 Hz / 63-120; 63-150 Hz 

Nominal Impedance  

6

Ω  

Recommended Amplification  

450 to 700 W 

/ 6 Ω (requires a 700 to 1000 W / 4 Ω amplifier) 

 

SPECIFICATIONS 

Model 

MSUB12 

Components 

1x 12 

‘’ – 6 Ohms – Long excursion – Neodymium driver 

Material 

Baltic birch plywood 

Finish 

Black or white structural paint 

Front finish 

UV Resistant acoustic fabric fitted Magnelis® front grille 

Fittings 

2x Side handles 

Stand fitting M20 

Connectors 

4x NL4, 4 poles connectors 

Weight 

23 kg 

– 51 lb 

Dimensions 

 

 

15,6

  6

17,0

4  

 1,7

550

Содержание MSUB12 Series

Страница 1: ...DP4308 01 DI MSUB12 User Manual ...

Страница 2: ...10 ARRAY EQ____________________________________________________________________________ 12 MAINTENANCE ________________________________________________________________________ 13 TECHNICAL SPECIFICATIONS ___________________________________________________________ 15 USER NOTES _________________________________________________________________________ 16 EU Conformity declaration We NEXO SA ZA DU PR...

Страница 3: ...accidentally If the system is used on a tripod please ensure the tripod s specifications are adapted and that it s height does not exceed 1 40m 55 Do not move the tripod with the system in position Connection and Powering Precautions Unplug connected cables before moving the system Power off the system before connecting the system When switching on the installation the amplifier must be powered la...

Страница 4: ...within the enclosure Amplification The MSUB12 must be used with a NEXO processor to handle EQ phase alignment crossover and excursion thermal protection for the system loudspeakers The following table shows the number of MSUB12 subwoofers usable with each solution DTD DTDAMP4x0 7 DTD DTDAMP4x1 3 NXAMP4x1MK2 NXAMP4x2MK2 NXAMP4x4MK2 GEOM620 Up to 2 per channel Up to 2 per channel Up to 3 per channel...

Страница 5: ...ubwoofer and a channel of amplifier 55 85 Hz 55 120 Hz 55 150 Hz 63 120 Hz 63 150 Hz CARDIO setups For a directional use cardioid of subwoofers require at least two subwoofers and two channels of amplifier Setups FR Front 55 85 Hz 55 120 Hz 55 150 Hz Setups BA Back 55 85 Hz 55 120 Hz 55 150 Hz The ideal ratio for a directional use is 2 x MSUB12 in CARDIO FRONT mode on top of 1x Reversed MSUB12 in ...

Страница 6: ...rossover should be used for GEOM6 as well For stack configuration using MSUB12 in OMNI or CARDIO mode with 1 Back and 2 Front and GEOM6 on top of them MSUB12 should use the 55 85 Hz setup 85 Hz crossover should be used for GEOM6 as well A small overlap could have impact if needed for example use MSUB12 with 55 120 Hz setup ...

Страница 7: ...age 7 20 With 4 to 6 GEOM6 For long throw application MSUB12 should use the 55 120 Hz setup 120 Hz crossover should be used for GEOM6 as well If a larger stacked Sub is used all together MSUB12 should use the 63 120 Hz setup ...

Страница 8: ...ETTING RANGE Page 8 20 MSUB12 With 7 to 12 GEOM6 For very long throw application MSUB12 should be deployed using the 55 120 Hz setup 120 Hz crossover should be used for GEOM6 Ground Stack Sub design T T ...

Страница 9: ...MSUB12 RIGGING MSUB12 Page 9 20 MSUB12 RIGGING Place MSUB12 on the top of a second MSUB12 Insert 4 quick release pins 6x15mm 2 on both sides VXT BL615 ...

Страница 10: ...nent is purchased from different supplier All MSUB12 accessories have been designed so that cabinet are arrayed vertically VNT BUMPM6 Rated for a maximum of 12 GEOM6 or 8 MSUB12 or a combination with a maximum of 4 MSUB12 and 6 GEOM6 Flown on 1 or 2 rigging points Usable with VNT EXBARM6 for extra tilt angle and flown on one or two rigging points 1 location for laser clinometer Use VXT BL615 or VN...

Страница 11: ...ck release pin 6x15mm for touring application MSUB12 MSUB12 MSUB12 VNT BUMPM6 VNT MNSTKM6 Stacking option for GEOM6 on top of MSUB12 with GMT BUMPER VNI FIXBUMPM6 Fixing kit for VNT BUMPM6 MSUB12 MST 2CASEMSUB12 For 2xMSUB12 and VNT BUMPM6 VNT EXBARM6 ...

Страница 12: ...ARRAY EQ Page 12 20 MSUB12 ARRAY EQ The ArrayEQ allows to adjust the system frequency response in its lower range see curves below with different ArrayEQ values ...

Страница 13: ...MAINTENANCE MSUB12 Page 13 20 MAINTENANCE Grille changing Remove 4 screws Tx25 Remove the grille 12 Driver Remove 8 screws Tx25 to remove the Driver Remove the driver Red Black ...

Страница 14: ...SUB12 UA Complete grille touring Black with fasteners 1 05MSUB12 UAPW Complete grille touring White with fasteners 3 4 05FTCC38x15 Pad 15 38 x10 4 1 05MS12 FPA CNX complete Black with screws and lexan 1 05MS12 FPA PW CNX complete White with screws and lexan 5 1 05HPB12ND 1 Driver 6 ohms 1 05N12ND 4R K Recone Kit 1 6 ohms NOTE Speakers and Grills can be sent back to NEXO for recycling 1 4 5 ...

Страница 15: ...3 150 Hz Nominal Impedance 6Ω Recommended Amplification 450 to 700 W 6 Ω requires a 700 to 1000 W 4 Ω amplifier SPECIFICATIONS Model MSUB12 Components 1x 12 6 Ohms Long excursion Neodymium driver Material Baltic birch plywood Finish Black or white structural paint Front finish UV Resistant acoustic fabric fitted Magnelis front grille Fittings 2x Side handles Stand fitting M20 Connectors 4x NL4 4 p...

Страница 16: ...USER NOTES Page 16 20 MSUB12 USER NOTES ...

Страница 17: ...USER NOTES MSUB12 Page 17 20 ...

Страница 18: ...USER NOTES Page 18 20 MSUB12 ...

Страница 19: ...USER NOTES MSUB12 Page 19 20 ...

Страница 20: ...USER NOTES Page 20 20 MSUB12 NEXO S A arc d activité de la Dame Jeanne F 60128 PLAILLY Tel 33 3 44 99 00 70 Fax 33 3 44 99 00 30 E mail info nexo fr nexo sa com ...

Отзывы: