background image

SPECIFICATIONS 

PAGE 7 OF 8 

Specifications 

 

DT D

AMP

4x0.7 

DT D

AMP

4x1.3 

Power specifications 

Number of channel 

4 x amplifiers channel, 2 by 2 bridgeable 

Max. output voltage (no load) 

4 x 85 Volts 

4 x 135 Volts 

Max. output power (4 x 8 Ohms) 

4 x 360 W atts 

4 x 750 W atts 

Max. output power (4 x 4 Ohms) 

4 x 700 W atts 

4 x 1300 W atts 

Max. output power (2 bridge x 8 Ohms) 

2 x 1400 W atts 

2 x 2600 W atts 

Audio characteristics 

Frequency Response 

+/- 0.5 dB from 20 Hz to 20 kHz 

Input Impedance 

10 kOhms 

Input Sensitivity 

+5 dBU 

+8 dBU 

Nominal Gain 

32 dB 

Dynamic Range (A-weighted) 

> 110 dB 

THD+N 

Typical 0.01 % 

Back panel features 

Analog audio input 

4 x balanced analog inputs on XLR3 

Power output 

4 x SP4 outputs 

Link switch 

To use same XLR input for 2 x adjacent channels 

Mains sockets 

IEC C14 inlet with secure lock 

Front panel features 

Switch and knobs 

Mains On/Off switch and volume control knob per channel 

View Meters 

4 x LEDs (Signal / -18 dB / -6 dB / Peak) per channel 

Amplifier status 

Amp Ready and Temperature indicator per channel pair 

Mains Requirements 

Mains Voltage 

Factory set for 120 volts or 230 volts mains operation 

Power consumption (Idle) 

65 W atts 

Power consumption 1/8 max. / 4 Ohms 

580 W atts 

900 W atts 

Power consumption 1/4 max. / 4 Ohms 

1100 W atts 

1800 W atts 

Physical specifications 

Dimensions (W  x H x D) 

480 (W ) x 44 (H) x 370 (D) mm, 19 inches / 1U 

W eight 

7.5 kg 

Operating temperature range 

0° C 

– 45 ° C 

Certifications 

CE conformity 

2006/95/CE (Low voltage) 2004/108/CE (EMC) 2002/95/CE (RoHS) 

Electrical safety certification 

CSA, CB, EN60065 

EMC certification 

EN55103-1 / EN55103-2 / FCC 

Ordering information 

Pre-configured for 230 volts mains 

DTD

AMP

4x0.7C 

DTD

AMP

4x1.3C 

Pre-configured for 120 volts mains 

DTD

AMP

4x0.7U 

DTD

AMP

4x1.3U 

 

Содержание DTDAMP4x0.7

Страница 1: ...DTDAMPAmplifiers DTDAMP4x0 7 DTDAMP4x1 3 User Manual v1 1 ...

Страница 2: ...tect thepower cord from beingwalked on or pinched particularly at plugs conveniencereceptacles and thepoint wherethey exit from theapparatus 11 Only useattachments accessoriesspecified by themanufacturer 12 Unplugthisapparatusduringlightningstormsor when unused for longperiods of time 13 Refer all servicingto qualified servicepersonnel S ervicingisrequired when the apparatus has been damaged in an...

Страница 3: ...onor fire Removethepower plugfrom theAC outlet whencleaningthedevice The performance of components with moving contacts such as switches volume controls and connectors deteriorates over time Consult qualified NE XO S A servicepersonnel about replacingdefectivecomponents Handlingcaution When turning on the AC power in your audio system always turn on the device FIRS T to avoid speaker damage When t...

Страница 4: ...eakers With the DTD I power output of the DTDAMP will have to be spit in two one side used for DTD I feedback the other one going to thespeakers W ARNING Unplug the device from mains before connecting or disconnectingany cableto it ConnectingtheDTDAMP audioinputs Use the back panel female XLR3 connectors to connect the balanced analoginput signal typically from aDTD Controller output For each pair...

Страница 5: ...set up thevolumecontrol to the0 dBposition W ARNING When used in bridge mode set the two volume control knobs of the channels bridged to the same position 0 dB for example Front panel LE Dsdispla y 20 LE Dswill report thestatusof theDTDAMP to theuser For CH1 CH2 on one side and CH3 CH4 on the other side two RE ADY Green LE Ds will light once the channel is ready for use For CH1 CH2 on one side and...

Страница 6: ...DTDAMP OUTPUT WIRING PAGE 6 OF 8 DTDAMPOutput wiring DTDAMP 4xchannelmodetoDTD T DTDAMP 2xbridgedchannelmodetoDTD T ...

Страница 7: ...ins sockets IEC C14 inlet with secure lock Front panel features S witch and knobs Mains On Off switch and volume control knob per channel View Meters 4 x LEDs S ignal 18 dB 6 dB Peak per channel Amplifier status Amp Ready and Temperature indicator per channel pair Mains Requirements Mains Voltage Factory set for 120 volts or 230 volts mains operation Power consumption Idle 65 Watts Power consumpti...

Страница 8: ... Pre de la Dame J eanne 60128 Plailly France CE Mark first affixed in 2016 to whichthisdeclaration relatesisin conformity withthefollowingstandard s or other normativedocument s CE Directives2006 95 EC Low Voltage 2004 108 EC EMC 2002 95 EC RoHs EN 55103 1 2009 A1 2012 EN 55103 2 2009 IS 2012 FCC Part 15 2013 EN 60065 2002 A1 2006 A11 2008 A2 2010 A12 2011 IEC60065 ed 7 AM1 AM2 includingnational d...

Отзывы: