background image

IMPORTANT NOTICE FOR THE UNITED KINGDOM 

PAGE 3 OF 8 

Location 

• Before moving the device, remove all connected cables. 

• When setting up the device, make sure that the AC outlet you are using is easily 
accessible. If some trouble or malfunction occurs, immediately turn off the power 
switch and disconnect the plug from the outlet. Even when the power switch is 
turned off, electricity is still flowing to the product at the minimum level. When 
you are not using the product for a long time, make sure to unplug the power 
cord from the wall AC outlet. 

• If this device is to be mounted in an EIA-standard rack, leave the back of the 
rack open and make sure that it is at least 10 cm away from walls or surfaces. 
Also, if this device is to be mounted with devices that tend to generate heat, such 
as power amplifiers, be sure to keep an adequate gap between this device and the 
heat-generating devices or install ventilation panels to prevent high temperatures 
from developing inside this device. 

• Inadequate ventilation can result in overheating, possibly causing damage to the 
device(s), or even fire. 

• Do not use the device in a confined, poorly-ventilated location. If this device is 
to be used in a small space other than an EIA-standard rack, make sure that there 
is adequate space between the device and surrounding walls or other devices: at 
least 10 cm at the sides, 15 cm behind and 40 cm above. Inadequate ventilation 
can result in overheating, possibly causing damage to the device(s), or even fire. 

•  Do not expose the device to excessive dust or vibrations, or extreme cold or 
heat  (such  as  in  direct  sunlight,  near  a  heater,  or  in  a  car  during  the  day)  to 
prevent  the  possibility  of  panel  disfiguration  or  damage  to  the  internal 
components. 

• Do not place the device in an unstable position where it might accidentally fall 
over. 

• Do not block the vents. This device has ventilation holes at the sides to prevent 
the internal temperature from becoming too high. In particular, do not place the 
device  on  its  side  or  upside  down.  Inadequate  ventilation  can  result  in 
overheating, possibly causing damage to the device(s), or even fire. 

• Do not use the device in the vicinity of a TV, radio, stereo equipment, mobile 
phone, or other electric devices. Doing so may result in noise, both in the device 
itself and in the TV or radio next to it. 

Connections 

•  Before  connecting  the  device  to  other  devices,  turn  off  the  power  for  all 
devices. Before turning the power on or off for all devices, set all volume levels to 
minimum. 

• Use only speaker cables for connecting speakers to the speaker jacks. Use of 
other types of cables may result in fire. 

• XLR-type connectors are wired as follows (IEC60268 standard): pin 1: ground, 
pin 2: hot (+) and pin 3: cold (-). 

• Use only SP4 plugs for connecting SP connectors. 

Maintenance 

•  Inspect  the  ventilation  holes  and  clean  them  periodically.  Dust  and  dirt  can 
seriously degrade the effectiveness of the cooling and result in malfunction or fire. 

• Remove the power plug from the AC outlet when cleaning the device. 

•  The  performance  of  components  with  moving  contacts,  such  as  switches, 
volume  controls,  and  connectors,  deteriorates  over  time.  Consult  qualified 
NEXO-SA service personnel about replacing defective components. 

Handling caution 

•  When  turning  on  the  AC  power  in  your  audio  system,  always  turn  on  the 
device FIRST, to avoid speaker damage. When turning the power off, the device 
should be turned off LAST for the same reason. 

•  Do  not  insert  your  fingers  or  hands  in  any  gaps  or  openings  on  the  device 
(vents…) 

• Avoid inserting or dropping foreign objects (paper, plastic, metal, etc.) into any 
gaps or openings on the device (vents, etc.) If this happens, turn off the power 
immediately  and  unplug  the  power  cord  from  the  AC  outlet.  Then  have  the 
device inspected by qualified NEXO-SA service personnel. 

• Do not use the device for a long period of time at a high or uncomfortable 
volume level, since this can cause permanent hearing loss. If you experience any 
hearing loss or ringing in the ears, consult a physician. 

• Do not rest your weight on the device or place heavy objects on it, and avoid 
use excessive force on the buttons, switches or connectors. 

• Do not use this device for any purpose other than driving loudspeakers. 

Important notice for the United Kingdom 

Connecting the Plug and Cord 

 

W ARN IN G!

 THIS APPARATUS MUST BE EARTHED. IMPORTANT: 

The wires in this mains lead are colored in accordance with the following code: 

GREEN-AND-YELLOW: EARTH 
BLUE: NEUTRAL 
BROWN: LIVE 

WARNING: As the colors of the wires in the mains lead of this apparatus may 
not correspond with the colored markings identifying the terminals in your plug 

proceed as follows: 

• The wire which is colored GREEN-and-YELLOW must be connected to the 
terminal in the plug which is marked by the letter E or by the safety earth symbol   
or colored GREEN or GREEN-and-YELLOW. 

• The wire which is colored BLUE must be connected to the terminal which is 
marked with the letter N or colored BLACK. 

• The wire which is colored BROWN must be connected to the terminal which 
is marked with the letter L or colored RED. 

This applies only to products distributed in the United Kingdom. 

Compliance information statement (Declaration of 
conformity procedure) 

1) This device may not cause harmful interference, and 

2) This device must accept any interference received including interference that 

may cause undesired operation.  See user manual  instructions  if  interference  to 
radio reception is suspected. 

This applies only to products distributed in the United States of America. 

Important notice for Europe 

Purchaser/User Information specified in EN55103-1 and EN55103-2. 

Inrush Current: 26 A (DTD

AMP

4x0.7) 34 A (DTD

AMP

4x1.3) 

Conforms to Environments: E1, E2, E3 and E4. 

 

W ARNING!

 This   mark indicates a dangerous electrically live terminal. 

When connecting an external wire to this terminal, it is necessary either to have 
“a  person  who  have  received  appropriate  guidance  on  handling”  make  the 
connection or to use leads or a cord that have been manufactured in such way 
that the connection can be made simply and without problem.

  

 

 

Содержание DTDAMP4x0.7

Страница 1: ...DTDAMPAmplifiers DTDAMP4x0 7 DTDAMP4x1 3 User Manual v1 1 ...

Страница 2: ...tect thepower cord from beingwalked on or pinched particularly at plugs conveniencereceptacles and thepoint wherethey exit from theapparatus 11 Only useattachments accessoriesspecified by themanufacturer 12 Unplugthisapparatusduringlightningstormsor when unused for longperiods of time 13 Refer all servicingto qualified servicepersonnel S ervicingisrequired when the apparatus has been damaged in an...

Страница 3: ...onor fire Removethepower plugfrom theAC outlet whencleaningthedevice The performance of components with moving contacts such as switches volume controls and connectors deteriorates over time Consult qualified NE XO S A servicepersonnel about replacingdefectivecomponents Handlingcaution When turning on the AC power in your audio system always turn on the device FIRS T to avoid speaker damage When t...

Страница 4: ...eakers With the DTD I power output of the DTDAMP will have to be spit in two one side used for DTD I feedback the other one going to thespeakers W ARNING Unplug the device from mains before connecting or disconnectingany cableto it ConnectingtheDTDAMP audioinputs Use the back panel female XLR3 connectors to connect the balanced analoginput signal typically from aDTD Controller output For each pair...

Страница 5: ...set up thevolumecontrol to the0 dBposition W ARNING When used in bridge mode set the two volume control knobs of the channels bridged to the same position 0 dB for example Front panel LE Dsdispla y 20 LE Dswill report thestatusof theDTDAMP to theuser For CH1 CH2 on one side and CH3 CH4 on the other side two RE ADY Green LE Ds will light once the channel is ready for use For CH1 CH2 on one side and...

Страница 6: ...DTDAMP OUTPUT WIRING PAGE 6 OF 8 DTDAMPOutput wiring DTDAMP 4xchannelmodetoDTD T DTDAMP 2xbridgedchannelmodetoDTD T ...

Страница 7: ...ins sockets IEC C14 inlet with secure lock Front panel features S witch and knobs Mains On Off switch and volume control knob per channel View Meters 4 x LEDs S ignal 18 dB 6 dB Peak per channel Amplifier status Amp Ready and Temperature indicator per channel pair Mains Requirements Mains Voltage Factory set for 120 volts or 230 volts mains operation Power consumption Idle 65 Watts Power consumpti...

Страница 8: ... Pre de la Dame J eanne 60128 Plailly France CE Mark first affixed in 2016 to whichthisdeclaration relatesisin conformity withthefollowingstandard s or other normativedocument s CE Directives2006 95 EC Low Voltage 2004 108 EC EMC 2002 95 EC RoHs EN 55103 1 2009 A1 2012 EN 55103 2 2009 IS 2012 FCC Part 15 2013 EN 60065 2002 A1 2006 A11 2008 A2 2010 A12 2011 IEC60065 ed 7 AM1 AM2 includingnational d...

Отзывы: