FCC INFORMATION (U.S.A.) 

1. IMPORTANT NOTICE: DO NOT MODIFY THIS UNIT! 

This  product,  when  installed  as  indicated  in  the  instructions  contained  in  this 

manual,  meets  FCC  requirements.  Modifications  not  expressly  approved  by 

NEXO-SA may void your authority, granted by the FCC, to use the product. 

2. IMPORTANT: 

When  connecting  this  product  to  accessories  and/or  another  product  use  only 

high quality shielded cables. Cable/s supplied with this product if any MUST be 

used. Follow all installation instructions. Failure to follow instructions could void 

your FCC authorization to use this product in the USA. 

3. NOTE: 

This product has been tested and found to comply with the requirements listed 

in FCC Regulations, Part 15 for Class “B” digital devices. Compliance with these 

requirements  provides  a  reasonable  level  of  assurance  that  your  use  of  this 

product in a residential environment will not result in harmful interference with 

other electronic devices. This equipment generates/uses radio frequencies and, 

if  not  installed  and  used  according  to  the  instructions  found  in  the  users 

manual,  may  cause  interference  harmful  to  the  operation  of  other  electronic 

devices. Compliance with FCC regulations does not guarantee that interference 

will  not  occur  in  all  installations.  If  this  product  is  found  to  be  the  source  of 

interference,  which  can  be  determined  by  turning  the  unit  “OFF”  and  “ON”, 

please try to eliminate the problem by using one of the following measures: 

Relocate  either  this  product  or  the  device  that  is  being  affected  by  the 

interference. 

Utilize  power  outlets  that  are  on  different  branch  (circuit  breaker  or  fuse) 

circuits or install AC line filter/s. 

In  the  case  of  radio  or  TV  interference,  relocate/reorient  the  antenna.  If  the 

antenna  lead-in  is  300  ohm  ribbon  lead,  change  the  lead-in  to  co-axial  type 

cable. 

If these corrective measures do not produce satisfactory results, please contact 

the  local  retailer  authorized  to  distribute  this  type  of  product.  If  you  can  not 

locate  the  appropriate  retailer,  please  contact  the  After  Sales  department  of 

NEXO-SA, Parc d’Activité du Pré de la Dame Jeanne, B.P. 5, 60128 PLAILLY 

The above statements apply ONLY to those products distributed by NEXO-SA or 

its subsidiaries. 

 

* This applies only to products distributed in the United States of America.  

 

 

IMPORTANT SAFETY INSTRUCTIONS 

1 Read these instructions. 

2 Keep these instructions. 

3 Heed all warnings. 

4 Follow all instructions. 

5 Do not use this apparatus near water. 

6 Clean only with dry cloth. 

7 Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions. 

8 Do not install near any heat sources such as radiators, heat registers, 

stoves, or other apparatus (including amplifiers) that produce heat. 

9 Do not defeat the safety purpose of the polarized or grounding-type 

plug. A polarized plug has two blades with one wider than the other. A 

grounding type plug has two blades and a third grounding prong. The 

wide  blade  or  the  third  prong  are  provided  for  your  safety.  If  the 

provided  plug  does  not  fit  into  your  outlet,  consult  an  electrician  for 

replacement of the obsolete outlet. 

10 Protect the power cord from being walked on or pinched particularly 

at plugs, convenience receptacles, and the point where they exit from 

the apparatus. 

11 Only use attachments/accessories specified by the manufacturer. 

12 Unplug this apparatus during lightning storms or when unused for 

long periods of time. 

13  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is 

required  when  the  apparatus  has  been  damaged  in  any  way,  such  as 

power-supply  cord  or  plug  is  damaged,  liquid  has  been  spilled  or 

objects have fallen into the apparatus, the apparatus has been exposed 

to rain or moisture, does not operate normally, or has been dropped. 

 

PRECAUTIONS 

Please read carefully before proceeding. Please keep this manual in a safe place for future reference. 
 
 

 

WARNING 

Always follow the basic precautions listed below to avoid the possibility of serious injury or even death from electrical shock, short-circuiting, 
damages, fire or other hazards. These precautions include, but are not limited to, the following: 

 

 

Содержание Digital Patching Unit

Страница 1: ...DPU DPU DPU DPU Digital Digital Digital Digital Patching Unit Patching Unit Patching Unit Patching Unit QUICK START v1 2 ...

Страница 2: ...ct If you can not locate the appropriate retailer please contact the After Sales department of NEXO SA Parc d Activité du Pré de la Dame Jeanne B P 5 60128 PLAILLY The above statements apply ONLY to those products distributed by NEXO SA or its subsidiaries This applies only to products distributed in the United States of America IMPORTANT SAFETY INSTRUCTIONS 1 Read these instructions 2 Keep these ...

Страница 3: ...roduct for a long time make sure to unplug the power cord from the wall AC outlet If this device is to be mounted in an EIA standard rack leave the back of the rack open and make sure that it is at least 10 cm away from walls or surfaces Also if this device is to be mounted with devices that tend to generate heat such as power amplifiers be sure to keep an adequate gap between this device and the ...

Страница 4: ...rth symbol or colored GREEN or GREEN and YELLOW The wire which is colored BLUE must be connected to the terminal which is marked with the letter N or colored BLACK The wire which is colored BROWN must be connected to the terminal which is marked with the letter L or colored RED This applies only to products distributed in the United Kingdom COMPLIANCE INFORMATION STATEMENT DECLARATION OF CONFORMIT...

Страница 5: ...icate which speaker should be connected on which output When speakON 4 poles connectors should be used the LCD next to it will display the name of the speaker program chosen on the connected NXAMP When speakON 8 poles connectors are in use both LCDs on each side of the connectors will display the name of the connected speakers Back panel description 1 Mains connectors There is two mains connectors...

Страница 6: ...U Input A and C and connect the serial port using a crossover cable see serial port cabling bellow 3 3 3 3 Then connect at least one IEC cable to one of the IEC mains inlet of the DPU The left most display should lit and the message Stand by should appear on the screen 4 4 4 4 Connect the NXAMP mains plug s and turn the NXAMP ON Check the LOAD revision while booting up it should be LOAD3_10 or abo...

Страница 7: ...tains a copy of all the parameters and preset of the failed amplifier One scene or user preset has to be created for every normal amplifier in a redundant system and saved in the backup amplifier s memory space from 00 to 04 DPU is used in reverse within a redundancy system Meaning that power signals from normal NXAMPs are connected to the front DPU s connectors and outputted to the speakers using...

Страница 8: ...t TBD TBD GPOutput 4 Out TBD TBD GPOutput 5 Out TBD TBD GPOutput 6 Out TBD TBD GPOutput 7 Out TBD TBD GPOutput 8 Out TBD TBD When an impulse is detected on GPInput1 Usersetup 00 is recalled When an impulse is detected on GPInput2 Usersetup 01 is recalled When an impulse is detected on GPInput3 Usersetup 02 is recalled When an impulse is detected on GPInput4 Usersetup 03 is recalled When an impulse...

Страница 9: ...GPOutput 3 Out TBD TBD GPOutput 4 Out TBD TBD GPOutput 5 Out TBD TBD GPOutput 6 Out TBD TBD GPOutput 7 Out TBD TBD GPOutput 8 Out TBD TBD When signal on GPInput1 is 0 no amplifier has failed and the backup amplifier is still free and ready to take over When signal on GPInput1 is 1 one or more amplifiers have failed all DPUs that are connected to the backup amplifier are frozen One DPU has already ...

Страница 10: ...or Null modem cables 6 Then connect the mains to all NXAMPs and DPU using POWERCONs and IEC cables 7 Power on all the NXAMPs and DPUs 8 Then create scenes or user presets in the back up amplifier that contain a copy of each normal amplifier parameters and speaker setup Go to the backup NXAMP menu 4 Save Recall save choose the scenes name example 00 nxamp1 01 nxamp2 and save Memory spaces 00 to 04 ...

Страница 11: ...17 18 19 27 26 J6 DConnec r25 1 20 2 21 3 22 4 23 5 24 6 25 7 8 9 10 11 12 13 14 15 16 17 18 19 27 26 D Connec r 25 1 20 2 21 3 22 4 23 5 24 6 25 7 8 9 10 11 12 13 14 15 16 17 18 19 27 26 D Connec r 25 1 20 2 21 3 22 4 23 5 24 6 25 7 8 9 10 11 12 13 14 15 16 17 18 19 27 26 D Connec r 25 1 20 2 21 3 22 4 23 5 24 6 25 7 8 9 10 11 12 13 14 15 16 17 18 19 27 26 D Connec r 25 GND GND GND GND GND GND GN...

Страница 12: ... the backup amplifier analog inputs A B and C When saving the normal amplifiers parameters in the backup amplifier user memory space be careful especially for the audio signal patching Normal amplifiers input patch won t always be the same than the one saved in the backup amplifier user preset or scenes You could do exactly the same connections using EtherSound digitals audio inputs E F G and H An...

Страница 13: ...se 4 poles Speakons cables and 8 poles Speakons cables if you use more than 1 1 ratio backup normal Reproduce the same cabling pattern if you use more than three normal amplifiers Back side of the rack To Speakers To Speakers To Speakers Front side of the rack ...

Страница 14: ...U and NXAMP in a redundant system DB9 null modem or cross cables are used to connect the DPU to their host NXAMP using RS232 connectors The serial link is use to pilot the DPU when needed Back side of the rack Front side of the rack ...

Страница 15: ...DPU Digital Patching Unit DPU NXAMP4X1U NXAMP4X1U NXAMP4X1U NXAMP4X1U Powered Digital TD Controller 4x1U Powered Digital TD Controller 4x1U Powered Digital TD Controller 4x1U Powered Digital TD Controller 4x1U 110 110 110 110V V V V NXAMP4X1C NXAMP4X1C NXAMP4X1C NXAMP4X1C Powered Digital TD Controller 4x1C Powered Digital TD Controller 4x1C Powered Digital TD Controller 4x1C Powered Digital TD Con...

Страница 16: ...TE When using the DPU with the GPIO firmware the ratio of normal amplifier and backup amplifier is 1 1 WARNING Over voltage on pin 2 may damage your DPU please be sure that your GPIO output does not exceed 20V Internal connections in DPU schematized by double arrow Normal operation Mode Pin 2 5V Backup operation Mode Pin 2 0V Connection between SP4 1 and INPUTC connectors Same between SP4 2 and IN...

Отзывы: