background image

 

 

      

  

Redundancy using DPU without NXAMP 

A specific firmware has been developed for the DPU to be use with any amplifiers that possess a GPIO port. Uploading 

this new firmware into the DPU through the internal JTAG plug will convert the DPU’s RS232 serial port to a GPIO port.  

To load the firmware use a SILICON

 

LABORATORIES

 

ADAPTATEUR USB DEBUG for C8051FXX: DEBUGADPTR1-USB. 

 

 

 

 

This new GPIO port can be drive by any amplifier that provides a 5volts GPIO signal. The DPU will switch the power when 
the  voltage  on  pin  2  is  0V.

 

Do  not  forget  to  connect  the  ground  (Pin5),  between  the  DPU  and  the  backup 

amplifier. 

 

Pin Name 

In/Out 

Pin 2 is set high (5volts) 

Pin 2 from 1 (5Volts) to 0 

Pin 2 (RXD) 

In 

 ‘INPUT C’ and ‘INPUT A’ back DPU’s 
connectors are respectively connected to 
SP4-1 and SP4-2 connectors 

‘INPUT C’ and ‘INPUT A’ back DPU’s 
connectors are respectively connected to 
SP4-3 and SP4-4 connectors 

 

NOTE:

 When using the DPU with the GPIO firmware the ratio of normal amplifier and backup amplifier is 1:1. 

 

 WARNING:

 

Over voltage on pin 2 may damage your DPU, please be sure that your GPIO output does not exceed 20V

  

 

Internal connections in DPU 

(schematized by double arrow)

 

Normal operation Mode 

Pin 2 

= 5V 

Backup operation Mode 

Pin 2 

 = 0V 

 

Connection between SP4-1 and INPUTC connectors. (Same 

between SP4-2 and INPUTA connectors.) 

SP4-1  (1+) connected to INPUTC (1+) 

SP4-1 (1-) connected to  INPUTC (1-) 

SP4-1 (2+) connected to  INPUTC (2+) 

SP4-1 (2-) connected to  INPUTC (2-) 

 

Connection between SP4-3 and INPUTC connectors. (Same 

between SP4-4 and INPUTA connectors). 

SP4-3  (1+) connected to INPUTC (1+) 

SP4-3 (1-) connected to  INPUTC (1-) 

SP4-3 (2+) connected to  INPUTC (2+) 

SP4-3 (2-) connected to  INPUTC (2-) 

 

 WARNING: 

Do not exceed 10KW on DPU’s power connectors. 

Both  normal  and  backup  amplifiers  have to be fed with same audio signals (four different audio signals maximum) and 
run same speakers presets. 

DPU GPIO MODE (RS232 connector pin description) 

 

5.5V supply 30mA MAX 

 

Pin 3 (TXD) 

 

GPIO In (0V-5V) 

 

Pin 2 (RXD) 

 

Signal ground 

 

Pin 5 (GND) 

 

Unused 

 

Others 

Содержание Digital Patching Unit

Страница 1: ...DPU DPU DPU DPU Digital Digital Digital Digital Patching Unit Patching Unit Patching Unit Patching Unit QUICK START v1 2 ...

Страница 2: ...ct If you can not locate the appropriate retailer please contact the After Sales department of NEXO SA Parc d Activité du Pré de la Dame Jeanne B P 5 60128 PLAILLY The above statements apply ONLY to those products distributed by NEXO SA or its subsidiaries This applies only to products distributed in the United States of America IMPORTANT SAFETY INSTRUCTIONS 1 Read these instructions 2 Keep these ...

Страница 3: ...roduct for a long time make sure to unplug the power cord from the wall AC outlet If this device is to be mounted in an EIA standard rack leave the back of the rack open and make sure that it is at least 10 cm away from walls or surfaces Also if this device is to be mounted with devices that tend to generate heat such as power amplifiers be sure to keep an adequate gap between this device and the ...

Страница 4: ...rth symbol or colored GREEN or GREEN and YELLOW The wire which is colored BLUE must be connected to the terminal which is marked with the letter N or colored BLACK The wire which is colored BROWN must be connected to the terminal which is marked with the letter L or colored RED This applies only to products distributed in the United Kingdom COMPLIANCE INFORMATION STATEMENT DECLARATION OF CONFORMIT...

Страница 5: ...icate which speaker should be connected on which output When speakON 4 poles connectors should be used the LCD next to it will display the name of the speaker program chosen on the connected NXAMP When speakON 8 poles connectors are in use both LCDs on each side of the connectors will display the name of the connected speakers Back panel description 1 Mains connectors There is two mains connectors...

Страница 6: ...U Input A and C and connect the serial port using a crossover cable see serial port cabling bellow 3 3 3 3 Then connect at least one IEC cable to one of the IEC mains inlet of the DPU The left most display should lit and the message Stand by should appear on the screen 4 4 4 4 Connect the NXAMP mains plug s and turn the NXAMP ON Check the LOAD revision while booting up it should be LOAD3_10 or abo...

Страница 7: ...tains a copy of all the parameters and preset of the failed amplifier One scene or user preset has to be created for every normal amplifier in a redundant system and saved in the backup amplifier s memory space from 00 to 04 DPU is used in reverse within a redundancy system Meaning that power signals from normal NXAMPs are connected to the front DPU s connectors and outputted to the speakers using...

Страница 8: ...t TBD TBD GPOutput 4 Out TBD TBD GPOutput 5 Out TBD TBD GPOutput 6 Out TBD TBD GPOutput 7 Out TBD TBD GPOutput 8 Out TBD TBD When an impulse is detected on GPInput1 Usersetup 00 is recalled When an impulse is detected on GPInput2 Usersetup 01 is recalled When an impulse is detected on GPInput3 Usersetup 02 is recalled When an impulse is detected on GPInput4 Usersetup 03 is recalled When an impulse...

Страница 9: ...GPOutput 3 Out TBD TBD GPOutput 4 Out TBD TBD GPOutput 5 Out TBD TBD GPOutput 6 Out TBD TBD GPOutput 7 Out TBD TBD GPOutput 8 Out TBD TBD When signal on GPInput1 is 0 no amplifier has failed and the backup amplifier is still free and ready to take over When signal on GPInput1 is 1 one or more amplifiers have failed all DPUs that are connected to the backup amplifier are frozen One DPU has already ...

Страница 10: ...or Null modem cables 6 Then connect the mains to all NXAMPs and DPU using POWERCONs and IEC cables 7 Power on all the NXAMPs and DPUs 8 Then create scenes or user presets in the back up amplifier that contain a copy of each normal amplifier parameters and speaker setup Go to the backup NXAMP menu 4 Save Recall save choose the scenes name example 00 nxamp1 01 nxamp2 and save Memory spaces 00 to 04 ...

Страница 11: ...17 18 19 27 26 J6 DConnec r25 1 20 2 21 3 22 4 23 5 24 6 25 7 8 9 10 11 12 13 14 15 16 17 18 19 27 26 D Connec r 25 1 20 2 21 3 22 4 23 5 24 6 25 7 8 9 10 11 12 13 14 15 16 17 18 19 27 26 D Connec r 25 1 20 2 21 3 22 4 23 5 24 6 25 7 8 9 10 11 12 13 14 15 16 17 18 19 27 26 D Connec r 25 1 20 2 21 3 22 4 23 5 24 6 25 7 8 9 10 11 12 13 14 15 16 17 18 19 27 26 D Connec r 25 GND GND GND GND GND GND GN...

Страница 12: ... the backup amplifier analog inputs A B and C When saving the normal amplifiers parameters in the backup amplifier user memory space be careful especially for the audio signal patching Normal amplifiers input patch won t always be the same than the one saved in the backup amplifier user preset or scenes You could do exactly the same connections using EtherSound digitals audio inputs E F G and H An...

Страница 13: ...se 4 poles Speakons cables and 8 poles Speakons cables if you use more than 1 1 ratio backup normal Reproduce the same cabling pattern if you use more than three normal amplifiers Back side of the rack To Speakers To Speakers To Speakers Front side of the rack ...

Страница 14: ...U and NXAMP in a redundant system DB9 null modem or cross cables are used to connect the DPU to their host NXAMP using RS232 connectors The serial link is use to pilot the DPU when needed Back side of the rack Front side of the rack ...

Страница 15: ...DPU Digital Patching Unit DPU NXAMP4X1U NXAMP4X1U NXAMP4X1U NXAMP4X1U Powered Digital TD Controller 4x1U Powered Digital TD Controller 4x1U Powered Digital TD Controller 4x1U Powered Digital TD Controller 4x1U 110 110 110 110V V V V NXAMP4X1C NXAMP4X1C NXAMP4X1C NXAMP4X1C Powered Digital TD Controller 4x1C Powered Digital TD Controller 4x1C Powered Digital TD Controller 4x1C Powered Digital TD Con...

Страница 16: ...TE When using the DPU with the GPIO firmware the ratio of normal amplifier and backup amplifier is 1 1 WARNING Over voltage on pin 2 may damage your DPU please be sure that your GPIO output does not exceed 20V Internal connections in DPU schematized by double arrow Normal operation Mode Pin 2 5V Backup operation Mode Pin 2 0V Connection between SP4 1 and INPUTC connectors Same between SP4 2 and IN...

Отзывы: