background image

5

FORM NO. L-21261-B-0214

1.  Purchase a zero backlash flexible shaft coupler that 

accommodates the diameter of the sensor shaft (Item 
1) on one end and the dancer arm pivot shaft on the 
other end (See Figures 4 and 7).

2.  Slide the shaft coupler onto the dancer arm pivot shaft, 

inserting the shaft no further than half the thickness 
of the coupler clamp; then, tighten the clamp around 
the shaft (See Figure 4).

3.  The orientation of the Dancer Position Sensor (Item1) 

must be as shown in order to match the mid output of 
the Dancer Position Sensor to the mid travel position 
of the dancer arm (See Figure 5).  The DPS60A Dual 
sensor has two measurement ranges allowing for 
flexibility the in mounting position (See Figure 7). 

4.  Attach Dancer Position Sensor (Item 1) to one of 

the three hole configurations on the Bracket (Item 3) 
with the two shorter Pan Head Screws (Item 4), Flat 
Washers (Item 6), and Lock Washers (Item 5) (See 
Figure 4).

5.  Hand tighten the screws just enough to prevent sensor 

from moving during installation

 

(See Figure 4).

6.  Slide the Dancer Position Sensor (Item 1) into the 

coupling (See figure 4). 

7.  Measure the distance from the bottom of the Bracket 

(Item 3) to the machine’s side frame.  Fabricate a 
spacer block to make up the distance between the 
Bracket and the machine’s side frame (See Figure 
4).

8.  Slide the Dancer Position Sensor (Item 1) into the 

coupling again

 

with the spacer block in place on the 

machine’s side frame and mark the location  for the 
bracket’s two mounting holes.

9.  Remove the Dancer Position Sensor (Item 1) and 

Bracket (Item 3); then, drill and tap two 8-32 threaded 
holes centered within the marks drawn in Step 8.

10. With the dancer arm held firmly in its mid travel 

position, slide the Dancer Position Sensor (Item 1) 
into the coupling again making sure the sensor shaft 
marking is pointing toward the cable.

 
 

Insert the shaft no further than half the thickness of 
the coupling clamp. 

Figure  5

Figure  4

Dancer 

Arm

Pivot 

Shaft

Machine

Frame

Coupling

Spacer

Block

COUPLING CONNECTION

Customer supplied

Screws and

Lock Washers.

11.  Tighten the clamp around the sensor shaft (See Figure 

4).

12. Using customer supplied 8-32 screws and lock 

washers, secure the Bracket (Item 3) to the customer 
supplied spacer block and the machine’s side frame 
(See Figure 4).  

3

4

5

6

1

Midpoint of 

output when 

viewed from front. 

Alternative 

midpoint of 

output. 

Back

Front

Содержание 964518

Страница 1: ...1 FORM NO L 21261 B 0214 Dancer Position Sensor DPS60A Dual WEB CONTROL PRODUCTS User Manual...

Страница 2: ...ce until the machinery into which it is to be incorporated has been declared in conformity with the applicable provisions of the Directive Read this manual carefully before installation and operation...

Страница 3: ...BLE OF CONTENTS Introduction 4 Installation 4 Direct Connection 4 Coupling Connection 5 Electrical Connections 6 Adjustment 6 Troubleshooting 7 Mounting Dimensions 8 Parts List 9 Replacement Parts 9 S...

Страница 4: ...lowing for flexibility in the mounting position See Figure 7 4 Attach Dancer Position Sensor Item 1 to one of the three hole configurations on the Bracket Item 3 with two shorter Pan Head Screws Item...

Страница 5: ...g See figure 4 7 Measure the distance from the bottom of the Bracket Item 3 to the machine s side frame Fabricate a spacer block to make up the distance between the Bracket and the machine s side fram...

Страница 6: ...d in its mid travel position the sensor output should be approximately 5 VDC If it is not then slightly loosen the sensor s fasteners and rotate the sensor until the voltage reading is 5 VDC Refer to...

Страница 7: ...the Dancer Position Sensor accord ing to Figure 2 for Mid Point of Output and according to the instructions in the INSTALLATION and ADJUSTMENT sec tions Dancer arm exceeds the capacity of the sensor S...

Страница 8: ...FORM NO L 21261 B 0214 8 MOUNTING DIMENSIONS DANCER POSITION SENSOR Figure 9 9 9 390 48 6 1 91...

Страница 9: ...ts through your local Nexen Distributor DPS60A DUAL Product Number 964518 Supply Voltage 24 6 VDC Output Voltage 0 10VDC max angular rotation Reverse Polarity Protection 30VDC maximum Temperature 40o...

Страница 10: ...OTHER BREACH OF CONTRACT NEGLIGENCE OR OTHER TORT OR OTHERWISE EVEN IF NEXEN SHALL HAVE BEEN ADVISED OF THE POSSIBILITY OR LIKELIHOOD OF SUCH POTENTIAL LOSS OR DAMAGE For all of the purposes hereof t...

Отзывы: