Copyright © 2015 NEXCOM International Co., Ltd. All Rights Reserved.
3
NISE 50C/50C-H User Manual
Chapter 1: Product Introduction
Environment
▪
Operating Temperature:
Ambient with air flow: -5°C to 55°C
(According to IEC60068-2-1, IEC60068-2-2, IEC60068-2-14)
▪
Storage temperature: -30°C to 85°C
▪
Relative humidity: 10% to 95% (non-condensing)
▪
NISE 50C:
▪
Shock Protection:
– EMMC: 50G, half sine, 11ms, IEC60068-27
▪
NISE 50C:
▪
Vibration Protection w/ EMMC Condition:
– Random: 2Grms @ 5~500 Hz, IEC60068-2-64
– Sinusoidal: 2Grms @ 5~500 Hz, IEC60068-2-6
▪
NISE 50C-H:
▪
Shock Protection:
– HDD: 20G, half sine, 11ms, IEC60068-27
– SDD: 50G, half sine, 11ms, IEC60068-27
▪
NISE 50C-H:
▪
Vibration Protection w/HDD Condition:
– Random: 0.5Grms @ 5~500 Hz, IEC60068-2-64
– Sinusoidal: 0.5Grms @ 5~500 Hz, IEC60068-2-6
▪
NISE 50C-H:
▪
Vibration Protection SSD Condition:
– Random: 2Grms @ 5~500 Hz, IEC60068-2-64
– Sinusoidal: 2Grms @ 5~500 Hz, IEC60068-2-6
Certifications
▪
CE
▪
FCC Class A