background image

NEXCOM International Co., Ltd.

NEXCOM International Co., Ltd.

Published August 2019

www.nexcom.com

Intelligent Platform & Services Business Unit

Digital Signage Platform 
NDiS B327

User Manual

Содержание NDiS B327

Страница 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published August 2019 www nexcom com Intelligent Platform Services Business Unit Digital Signage Platform NDiS B327 User Manual ...

Страница 2: ...view 1 Key Features 1 Hardware Specifications 2 Physical Features 3 Front Panel 3 Rear Panel 3 Mechanical Dimensions 4 Chapter 2 Jumpers and Connectors Before You Begin 5 Precautions 5 Jumper Settings 6 Locations of the Jumpers and Connectors for NDiS B327 7 Top View 7 Bottom View 8 Jumpers 9 AT ATX Type Select 9 Connector Pin Definitions 10 External I O Interfaces Front Panel 10 USB 3 0 and USB 2...

Страница 3: ...DiS B327 User Manual Content Chapter 4 BIOS Setup About BIOS Setup 24 When to Configure the BIOS 24 Default Configuration 25 Entering Setup 25 Legends 25 BIOS Setup Utility 27 Main 27 Advanced 28 Security 35 Boot 35 Save Exit 36 Appendix A Watchdog Programming Guide 37 ...

Страница 4: ...of NEXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits for a Class A digital...

Страница 5: ...nd Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest industry ...

Страница 6: ...fective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Repair Service Charges for Out of Warrant...

Страница 7: ...and power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protection...

Страница 8: ...e the soft metal or plastic parts of the connectors Safety Information Before installing and using the device note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the system...

Страница 9: ...he voltage and current rating marked on the product 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened on...

Страница 10: ...ion of the installed software operating system version application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth Conventions Used in this Manual Warning Information about c...

Страница 11: ...hung Office 16F No 250 Sec 2 Chongde Rd Beitun Dist Taichung City 406 R O C Tel 886 4 2249 1179 Fax 886 4 2249 1172 Email sales nexcom com tw www nexcom com tw NexCOBOT Taiwan Co Ltd 13F No 916 Chung Cheng Rd ZhongHe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7796 Fax 886 2 8226 7792 Email sales nexcom com tw www nexcom com tw GreenBase Technology Corp 13F No 922 Chung Cheng Rd Zho...

Страница 12: ...mingzun Plaza Bldg 1 No 609 Yunlin East Rd Shanghai 200062 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email sales nexcom cn www nexcom cn NEXCOM Surveillance Technology Corp Floor 5 Building C ZhenHan Industrial Zone GanKeng Community Buji Street LongGang District ShenZhen 518112 China Tel 86 755 8364 7768 Fax 86 755 8364 7738 Email steveyang nexcom com tw www nexcom cn NEXCOM United System Ser...

Страница 13: ...k F3x5 Black Nylok 6 2 50311F0122X00 I Head Screw Long Fei I 2 6ISO M2x6mm Black Nylok 2 3 5061700886X00 HDD Bracket L for NDiS B328 Series VER A NACTEK 94x8x10mm SECC T 1 0mm 1 4 5061700987X00 HDD Bracket R for NDiS B327 VER A NACTEK 95x7 5x5mm SECC T 1 0mm 1 5 5040420019X00 Mini Card Bracket for NDiS M323 VER A CHYUAN JYH 29x30x2 1mm t 1 0mm SPCC NI 1 6 50311F0295X00 Flat Head Screw Long Fei F2x...

Страница 14: ...Ltd All Rights Reserved xiv NDiS B327 User Manual Preface Ordering Information The following below provides ordering information for NDiS B327 NDiS B327 P N 10W00B32701X4 Fanless Embedded Computer Powered by Intel Celeron N3060 SoC Processor ...

Страница 15: ...eatures Intel Celeron N3060 dual core SoC processor HDMI 4K resolution and VGA independent displays Two DDR3L SO DIMM memory up to 8G Support 6 x USB 4 x USB 3 0 2 x USB 2 0 Dual storage devices support include M 2 and 2 5 SATA Mini PCIe slot for optional WLAN module usage Compact chassis for limited space Fanless design without noise NDiS B327 Overview ...

Страница 16: ...switch with LED I O Interface Rear 1 x DC in jack 2 5 5 5mm 19V DC 1 x VGA 1920 x 1200 resolution 1 x HDMI 4K resolution 2 x Antenna holes 2 x USB 3 0 1 x RJ45 with LEDs for Gigabit LAN 1 x Line out 1 x Mic in Storage Device 1 x 2 5 SATA SSD bay 1 x M 2 2242 SSD SATA signal Expansion 1 x mini PCIe full size connector USB PCIe signal supports Wi Fi 1 x M 2 B key 2242 slot SATA support Dimensions 19...

Страница 17: ... Ltd All Rights Reserved 3 NDiS B327 User Manual Chapter 1 Product Introduction Physical Features Front Panel Rear Panel COM Port USB 2 0 USB 3 0 Storage LED Antenna Hole USB 3 0 DC IN HDMI LAN Antenna Hole Line out Mic in Power Button VGA ...

Страница 18: ...Copyright 2019 NEXCOM International Co Ltd All Rights Reserved 4 NDiS B327 User Manual Chapter 1 Product Introduction Mechanical Dimensions 25 31 147 2 190 110 76 202 214 ...

Страница 19: ...before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static electricity Wo...

Страница 20: ...e jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three Pin ...

Страница 21: ...N LINE_OUT HDMI VGA 1 SFIS USB_CON1 HDD_LED PWR_SW USB_CON2 SATA VGA HDMI USB3 LAN CON DC_PWR LINE_OUT Battery CON COM2 COM1 MIC_IN Locations of the Jumpers and Connectors for NDiS B327 Top View The figure below is the top and bottom view of the mainboard used in NDiS B327 It shows the locations of the jumpers and connectors ...

Страница 22: ...Copyright 2019 NEXCOM International Co Ltd All Rights Reserved 8 NDiS B327 User Manual Chapter 2 Jumpers and Connectors 1 1 65 97 33 1 MINI_PCIE M2B BIOS DIMM Bottom View ...

Страница 23: ... 9 NDiS B327 User Manual Chapter 2 Jumpers and Connectors Jumpers AT ATX Type Select Connector type 1x3 3 pin header Connector location CLRTC1 Pin Settings 1 2 On ATX Mode 2 3 On AT Mode 1 2 On default Pin Definition 1 PWR_BTN_SW 2 FB_PWSIN _R 3 AT_ATX_DET 1 3 1 3 ...

Страница 24: ... 13 13 Pin Definition Pin Definition 1 5V_USB3_P01 2 S_USB2DN0 3 S_USB2DP0 4 GND 5 S_U3RXDN0 6 S_U3RXDP0 7 GND 8 S_U3TXDN0 9 S_U3TXDP0 10 5V_USB3_P01 11 S_USB2DN1 12 S_USB2DP1 13 GND 14 GND 15 GND 16 GND 17 GND Pin Definition Pin Definition 1 5V_USB3_P23 2 S_USB2DN2 3 S_USB2DP2 4 GND 5 S_U3RXDN1 6 S_U3RXDP1 7 GND 8 S_U3TXDN1 9 S_U3TXDP1 10 GND 11 S_USB2DN3 12 S_USB2DP3 13 GND 14 GND 15 GND 16 GND ...

Страница 25: ...ctor type 1 x 3 5mm TRS Connector location MIC_IN Line out Connector Connector type 1 x 3 5mm TRS Connector location LINE_OUT Pin Definition Pin Definition 1 A_MIC1_L 2 A_MIC1_R 3 AGND 4 AGND 5 AGND 6 MIC1 JD 7 AGND 8 AGND 9 NC 10 NC Pin Definition Pin Definition 1 A_LOUT_L 2 A_LOUT_R 3 AGND 4 AGND 5 AGND 6 LINEOUT JD 7 AGND 8 AGND 9 NC 10 NC ...

Страница 26: ...al COM1 Connector Connector type 1x10 10 pin header Connector location COM1 Internal COM2 Connector Connector type 1x10 10 pin header Connector location COM2 Pin Definition Pin Definition 1 DCD1 2 RXD1 3 TXD1 4 DTR1 5 GND 6 DSR1 7 RTS1 8 CTS1 9 RI1 Pin Definition Pin Definition 1 DCD2 2 RXD2 3 TXD2 4 DTR2 5 GND 6 DSR2 7 RTS2 8 CTS2 9 RI2 ...

Страница 27: ...eserved 13 NDiS B327 User Manual Chapter 2 Jumpers and Connectors SPI Header Connector type 2x4 8 pin header Connector location SPI 1 7 2 8 Pin Definition Pin Definition 1 1 8V_SPI 2 SPI_CS0 _F 3 SPI_HOLD 4 SPI_SO_F 5 SPI_CLK_F 6 SPI_D2_WP 7 SPI_SI_F 8 GND ...

Страница 28: ...Cover Prior to removing the chassis cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage CAUTION CAUTION CAUTION 1 The screws on the bottom are used to secure the cover to the chassis Remove these screws and put them in a safe place for later use 2 Loosen the screws on the VGA connector ...

Страница 29: ...Copyright 2019 NEXCOM International Co Ltd All Rights Reserved 15 NDiS B327 User Manual Chapter 3 System Setup 3 With the screws removed push back the cover and remove it from the chassis ...

Страница 30: ...the mounting holes that are on the sides of the SATA drive with the mounting holes on the drive bay and then use the provided mounting screws to secure the drive in place Installing a SATA Storage 2 Place the SATA drive in the chassis and connect the SATA data connector then use screws to secure the drive in the chassis ...

Страница 31: ...cket Insert the module into the socket at an approximately 30 degree angle Push the module down until the clips on both sides of the socket lock into position The gold plated connector on the edge of the module will almost completely disappear inside the socket Installing SO DIMM Memory Modules SO DIMM 2 Push the module down until the clips on both sides of the socket lock into position You will h...

Страница 32: ... DIMM memory module With the bottom cover removed install a memory module in the SO DIMM socket Insert the module into the socket at an approximately 30 degree angle Push the module down until the clips on both sides of the socket lock into position The gold plated connector on the edge of the module will almost completely disappear inside the socket SO DIMM1 ...

Страница 33: ...r 3 System Setup 1 At the bottom of the system loosen the screws on the bottom cover and then remove the cover from the chassis Installing an M 2 SSD Storage Module The system is equipped with an M 2 B Key connector To install an M 2 SSD module please follow the instructions below M 2 B Key Slot ...

Страница 34: ...Chapter 3 System Setup 2 Insert the M 2 SSD module into the M 2 slot at a 45 degree angle until the gold plated connector on the edge of the module completely disappears inside the slot 3 With the module fully inserted tighten a screw into the mounting hole on the module to secure it Screw ...

Страница 35: ...lling a Wireless LAN Module The system is equipped with a mini PCIe slot for wireless LAN module To install the module please follow the instructions below Mini PCIe Slot 2 Insert the Wi Fi module into the slot at a 45 degree angle until the gold plated connector on the edge of the module completely disappears inside the slot Tighten a screw into the mounting hole on the module to secure it ...

Страница 36: ...tup 3 Attach the RF cables onto the Wi Fi module and insert the antenna jack end of the cables through the antenna holes RF Cable 4 Insert the 2 rings ring 1 then ring 2 into the Wi Fi antenna jacks Please remove the two antenna hole covers on the front panel before installing the antenna jacks Ring 2 Ring 1 ...

Страница 37: ...Copyright 2019 NEXCOM International Co Ltd All Rights Reserved 23 NDiS B327 User Manual Chapter 3 System Setup 5 Connect the external antennas to the Wi Fi antenna jacks Antenna ...

Страница 38: ...is configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all the setup o...

Страница 39: ...l be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing Del allows you to enter Setup Press the key to enter Setup Legends Key Function Moves the highlight left o...

Страница 40: ...tup screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Страница 41: ...econd The time is based on the 24 hour military time clock For example 1 p m is 13 00 00 Hour displays hours from 00 to 23 Minute displays minutes from 00 to 59 Second displays seconds from 00 to 59 Advanced Security Boot Save Exit Main Version 2 18 1264 Copyright C 2018 American Megatrends Inc Aptio Setup Utility Copyright C 2018 American Megatrends Inc Select Screen Select Item Enter Select Chan...

Страница 42: ...Trusted Computing ACPI Settings NCT6793D Super IO Configuration Hardware Monitor CPU Configuration PPM Configuration SATA Configuration Network Stack Configuration CSM Configuration USB Configuration Restore AC Power Loss SIO Configures the power state when power is re applied after a power failure Trusted Computing This section is used to configure Trusted Platform Module TPM settings Advanced Ve...

Страница 43: ...ble Hibernation Enables or disables system ability to hibernate OS S4 Sleep State This option may not be effective with some operating systems ACPI Sleep State Select the highest ACPI sleep state the system will enter when the suspend button is pressed The options are Suspend Disabled and S3 Suspend to RAM NCT6793D Super IO Configuration This section is used to configure the serial ports Super IO ...

Страница 44: ... Inc Aptio Setup Utility Copyright C 2018 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable or Disable Serial Port COM Serial Port 1 Configuration Serial Port Device Settings Enabled IO 3F8h IRQ 4 Advanced Version 2 18 1264 Copyright C 2018 American Megatrends Inc Aptio Setup Utility Copyr...

Страница 45: ... Status CPU Temperature System Temperature VCORE 3V 5V 12V 1 35VDUAL 30 ºc 28 ºc 0 888 V 3 376 V 5 064 V 12 960 V 1 392 V CPU Configuration This section is used to view CPU status and configure CPU parameters Intel Virtualization Technology When this field is set to Enabled the VMM can utilize the additional hardware capabilities provided by Vanderpool Technology Power Technology Enables or disabl...

Страница 46: ...xit Main Version 2 18 1264 Copyright C 2018 American Megatrends Inc Aptio Setup Utility Copyright C 2018 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable Disable SATA Device SATA Configuration SATA Controller SATA Mode Selection SATA Port0 Not Present Port 0 SATA Port1 Not Present Port 1 ...

Страница 47: ...n Version 2 18 1264 Copyright C 2018 American Megatrends Inc Aptio Setup Utility Copyright C 2018 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Enable Disable CSM Support Compatibility Support Module Configuration CSM Support CSM16 Module Version Boot option filter Option ROM execution Networ...

Страница 48: ...t AUTO option disables legacy support if no USB devices are connected DISABLE option will keep USB devices available only for EFI applications USB Configuration USB Module Version USB Controllers 1 XHCI USB Devices 1 Keyboard 1 Hub Legacy USB Support XHCI Hand off USB hardware delays and time outs Device reset time out 17 Enabled Enabled 20 sec Legacy USB Support Enabled Enables Legacy USB Auto Di...

Страница 49: ...gth 20 Administrator Password User Password Administrator Password Select this to reconfigure the administrator s password User Password Select this to reconfigure the user s password Boot Bootup NumLock State This allows you to determine the default state of the numeric keypad By default the system boots up with NumLock on wherein the function of the numeric keypad is the number keys When set to ...

Страница 50: ...s Values F3 Optimized Defaults F4 Save Exit ESC Exit Reset the system after saving the changes Save Options Save Changes and Reset Discard Changes and Reset Default Options Restore Defaults Save Exit Save Changes and Reset To save the changes and restart the system select this field then press Enter A dialog box will appear Confirm by selecting Yes You can also press F4 to save and exit Setup Disc...

Страница 51: ...ty in industrial standalone or unmanned environments NCT6793 Watchdog Programming Guide define SUPERIO_PORT 0x2E define WDT_SET 0xF8 define WDT_VALUE 0xF9 void main void Enter SuperIO Configuration outportb SUPERIO_PORT 0x87 outportb SUPERIO_PORT 0x87 Set LDN outportb SUPERIO_PORT 0x07 outportb SUPERIO_PORT 1 0x08 Set WDT setting outportb SUPERIO_PORT WDT_SET outportb SUPERIO_PORT 1 0x00 Use the s...

Отзывы: