Содержание NDiS B325 Series

Страница 1: ...NEXCOM International Co Ltd NEXCOM International Co Ltd Published June 2017 www nexcom com Intelligent Platform Services Business Unit Digital Signage Platform NDiS B325 Series User Manual ...

Страница 2: ...er 1 Product Introduction NDiS B325 1 Overview 1 Key Features 1 Hardware Specifications 2 Knowing Your NDiS B325 Series 3 Front Panel 3 Rear Panel 4 Mechanical Dimensions 5 Chapter 2 Jumpers and Connectors Before You Begin 6 Precautions 6 Jumper Settings 7 Location of the Jumpers and Connectors 8 Top View 8 Bottom View 9 Connector Button Table 10 Header Wafer Table 10 Chapter 3 System Setup Instal...

Страница 3: ...Copyright 2016 NEXCOM International Co Ltd All Rights Reserved iii NDiS B325 Series User Manual Content Security 28 Boot 28 Save Exit 30 Appendix A Watchdog 31 ...

Страница 4: ... SI5 are trademarks of NEXCOM International Co Ltd All other product names mentioned herein are registered trademarks of their respective owners Regulatory Compliance Statements This section provides the FCC compliance statement for Class A devices and describes how to keep the system CE compliant Declaration of Conformity FCC This equipment has been tested and verified to comply with the limits f...

Страница 5: ...m and Polybrominated diphenyl Ethers PBDE 0 1 or 1 000ppm In order to meet the RoHS compliant directives NEXCOM has established an engineering and manufacturing task force to implement the introduction of green products The task force will ensure that we follow the standard NEXCOM development procedure and that all the new RoHS components and new manufacturing processes maintain the highest indust...

Страница 6: ... defective products making sure it is durable enough to be resistant against further damage and deterioration during transportation In case of damages occurred during transportation the repair is treated as Out of Warranty Any products returned by NEXCOM to other locations besides the customers site will bear an extra charge and will be billed to the customer Repair Service Charges for Out of Warr...

Страница 7: ...is and power supply are inconsistent with these instructions or the instructions for accessory modules contact the supplier to find out how you can ensure that your computer meets safety and regulatory requirements Cautions Electrostatic discharge ESD can damage system components Do the described procedures only at an ESD workstation If no such station is available you can provide some ESD protect...

Страница 8: ...amage the soft metal or plastic parts of the connectors Safety Information Before installing and using the device note the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Follow all warnings and cautions in this manual When replacing parts ensure that your service technician uses parts specified by the manufacturer Avoid using the sy...

Страница 9: ...n the voltage and current rating marked on the product 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient overvoltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened...

Страница 10: ...rmation of the installed software operating system version application software etc A complete description of the problem The exact wordings of the error messages Warning 1 Handling the unit carry the unit with both hands and handle it with care 2 Maintenance to keep the unit clean use only approved cleaning products or clean with a dry cloth Conventions Used in this Manual Warning Information abo...

Страница 11: ... No 920 Chung Cheng Rd ZhongHe District New Taipei City 23586 Taiwan R O C Tel 886 2 8226 7796 Fax 886 2 8226 7792 Email sales nexcom com tw www nexcom com tw NEXCOM Intelligent Systems Taichung Office 16F No 250 Sec 2 Chongde Rd Beitun Dist Taichung City 406 R O C Tel 886 4 2249 1179 Fax 886 4 2249 1172 Email sales nexcom com tw www nexcom com tw Japan NEXCOM Japan 9F Tamachi Hara Bldg 4 11 5 Shi...

Страница 12: ... www nexcomitalia it NEXCOM Shanghai Room 603 604 Huiyinmingzun Plaza Bldg 1 No 609 Yunlin East Rd Shanghai 200333 China Tel 86 21 5278 5868 Fax 86 21 3251 6358 Email sales nexcom cn www nexcom cn NEXCOM Surveillance Technology Corp Room202 Building B the GuangMing Industrial Zone Zhonghua Rd Minzhi Street Longhua District Shenzhen 518131 China Tel 86 755 8364 7768 Fax 86 755 8364 7738 Email steve...

Страница 13: ...er Manual Preface Package Contents Before continuing verify that the NDiS B325 series package that you received is complete Your package should have all the items listed in the following table Item Name Qty 1 Power adapter 1 2 HDD Bracket Kit 1 3 Driver DVD 1 Power Adapter HDD Bracket Kit ...

Страница 14: ...vides ordering information for the NDiS B325 series Barebone NDiS B325 P N 10WOOB32500X0 Intel Celeron J3160 Quad Core fanless system NDiS B325 SI3 P N 10W00B32506X0 Intel CoreTM i3 6100U Dual Core fanless system NDiS B325 SI5 P N 10W00B32502X0 Intel CoreTM i5 6200U Dual Core fanless system Optional VESA Mount Kit 1 x VESA Mount Bracket 4 x Screws ...

Страница 15: ...ficant improvements up to two and a half times the performance in graphics offering stunning visuals for compelling 4K content creation and media playback NDiS B325 series supports display output by HDMI and VGA ports J3160 NDiS B325 J3160 is ideal as entry level digital signage player NDiS B325 SI3 SI5 i3 6100U i5 6200U are high performance players adding integration flexibility with various peri...

Страница 16: ... Front 1x Power LED NDiS B325 1x Power Switch with LED NDiS B325 SI3 SI5 2x USB 3 0 2x USB 2 0 1x DB9 for RS 232 I O Interface Rear 19V DC in 1x HDMI 4K Resolution 1x VGA NDiS B325 only NDiS B325 SI3 SI5 changed to HDMI 2x USB 3 0 1x RJ45 with LED for 10 100 1000Mbps Ethernet 1x Line out 1x Mic in 2x Antenna holes for Wi Fi or TV tuner Storage 1x 2 5 HDD SSD Dimensions 226 34 x 147 40 x 29 00 mm w...

Страница 17: ...Port The COM port supports RS232 compatible serial devices USB 2 0 Ports Used to connect USB 2 0 1 1 devices USB 3 0 Ports Used to connect USB 3 0 2 0 1 1 devices Power LED Power Switch Displays the power status of the system Power switch to power on off NDiS B325 SI3 SI5 COM USB 2 0 USB 3 0 Power LED COM USB 2 0 USB 3 0 Power LED Power Switch NDiS B325 NDiS B325 SI3 SI5 ...

Страница 18: ...0 Ports Used to connect USB 3 0 2 0 1 1 devices LAN Used to connect the system to a local area network 19V DC Input Used to plug a DC power cord Line out Used to connect a headphone or a speaker Mic in Used to connect an external microphone Antenna Hole for Optional Wi Fi The external antenna mounting hole is used to mount and connect optional Wi Fi antennas USB 3 0 VGA Line out Antenna Hole HDMI ...

Страница 19: ...Copyright 2016 NEXCOM International Co Ltd All Rights Reserved 5 NDiS B325 Series User Manual Chapter 1 Product Introduction Mechanical Dimensions 29 200 60 90 6 3 2 N U T 214 224 34 5 147 40 ...

Страница 20: ...yourself before touching any internal components by touching a metal object Static electricity can damage many of the electronic components Humid environments tend to have less static electricity than dry environments A grounding strap is warranted whenever danger of static electricity exists Precautions Computer components and electronic circuit boards can be damaged by discharges of static elect...

Страница 21: ... the jumpers ensure that the jumper caps are placed on the correct pins When the jumper cap is placed on both pins the jumper is short If you remove the jumper cap or place the jumper cap on just one pin the jumper is open Refer to the illustrations below for examples of what the 2 pin and 3 pin jumpers look like when they are short on and open off Two Pin Jumpers Open Left and Short Right Three P...

Страница 22: ...International Co Ltd All Rights Reserved 8 NDiS B325 Series User Manual Chapter 2 Jumpers and Connectors MJ2 MJ4 J6 J211 J1 J110 J87 XBT1 SATA_HDD SYS FAN2 SW10 J11 J12 J96 J95 Location of the Jumpers and Connectors Top View ...

Страница 23: ...Copyright 2016 NEXCOM International Co Ltd All Rights Reserved 9 NDiS B325 Series User Manual Chapter 2 Jumpers and Connectors J49 Bottom View ...

Страница 24: ...J12 Dual USB 3 0 2 0 Connector SATA_HDD SATA HDD Connector J87 Microphone Input Connector J110 Audio Line out Connector J1 DC 19V Power in Connector J211 Dual USB 3 0 Connector J6 RJ45 Gigabit LAN Connector MJ4 HDMI Connector MJ2 VGA HDMI Connector J49 Half Size Mini PCIe M 2 Connector Connector Name SYS FAN2 HDD LED J95 COM1 Port Wafer J96 COM2 Port Wafer XBT1 RTC Battery Wafer Connector Button T...

Страница 25: ...em Setup Chapter 3 System Setup Installing a SATA HDD Prior to removing the chassis cover make sure the unit s power is off and disconnected from the power sources to prevent electric shock or system damage CAUTION CAUTION CAUTION 1 Remove the mounting screws around the chassis cover and then remove the cover ...

Страница 26: ...lign the mounting holes that are on the sides of the SATA drive with the mounting holes on the drive bay and then use the provided mounting screws to secure the drive in place 3 Place the SATA drive in the chassis and connect the SATA data connector then use the provided mounting screws to secure the drive in the chassis ...

Страница 27: ...des of the socket lock into position You will hear a distinctive click sound indicating the module is correctly locked into position 1 Insert the module into the socket at an approximately 30 degrees angle Apply firm even pressure to each end of the module until it slips into the socket The gold plated connector on the edge of the module will almost completely disappear inside the socket Memory mo...

Страница 28: ... includes the following items Mini PCIe Module Antennas RF Cables Installing a Mini PCIe M 2 Module Optional 2 Remove the Mini PCIe cover on the bottom of the chassis to locate the Mini PCIe slot Note M 2 is only available on NDiS B325 SI5 The below instructions use Mini PCIe module as an example but are also applicable for M 2 module installation ...

Страница 29: ...nual Chapter 3 System Setup 4 Secure the module with mounting screws and attach one end of the RF cables onto the module 3 Insert the Mini PCIe module into the Mini PCIe slot at a 45 degrees angle until the gold plated connector on the edge of the module completely disappears inside the slot ...

Страница 30: ...ll Rights Reserved 16 NDiS B325 Series User Manual Chapter 3 System Setup 5 Insert the antenna jack end of the cable through the antenna hole Antenna jack end of the cable 6 Insert the ring onto the antenna jack end of the cable Ring Antenna jack ...

Страница 31: ... User Manual Chapter 3 System Setup Installing the Wall Mount Kit 1 Align the mounting holes on the wall mount kit to the VESA mounting holes on the back of the monitor then secure the wall mount kit with screws 2 Secure the device to the wall mount bracket with screws Mounting hole ...

Страница 32: ...e system is configured with the values found in CMOS With easy to use pull down menus you can configure such items as Hard drives diskette drives and peripherals Video display type and display options Password protection from unauthorized use Power management features The settings made in the setup program affect how the computer performs It is important therefore first to try to understand all th...

Страница 33: ...will be reported in one of two different ways If the error occurs before the display device is initialized a series of beeps will be transmitted If the error occurs after the display device is initialized the screen will display the error message Powering on the computer and immediately pressing Del allows you to enter Setup Press the key to enter Setup Legends Key Function Moves the highlight lef...

Страница 34: ... setup screen it indicates that there are more available fields not shown on the screen Use the up and down arrow keys to scroll through all the available fields Submenu When appears on the left of a particular field it indicates that a submenu which contains additional options are available for that field To display the submenu move the highlight to that field and press ...

Страница 35: ...General Help F7 Discard Changes F9 Optimized Defaults F10 Save Exit ESC Exit Set the Time Use Tab to switch between Time elements System Overview AMIEFI BIOS Version Build Date System Memory Size System Time System Date MAC Address Halt On BSW P1 0314N12 12 07 2015 2048 MB DDR3L 16 37 26 Sun 01 04 2009 C0 7C D1 EF B1 5F No Errors System Date The date format is day month date year Day displays a da...

Страница 36: ...capabilities provided by Vanderpool Technology Configure advanced CPU settings CORE Count 4 Manufacturer Intel Intel R Celeron R CPU J3160 1 60GHz Frequency 1600 MHz Cache L1 24 KB x4 Cache L2 1024 KB x2 Ratio Actual Value 20 Virtualization Tech Disabled EIST tech Enabled CPU C6 report Enabled CPU C7 report Enabled Virtualization Tech When this field is set to Enabled the VMM can utilize the addit...

Страница 37: ...nfigure the SATA drives SATA Controller Enables or disables the SATA controller SATA Mode Selection Configures the SATA as AHCI mode AHCI This option configures the Serial ATA drives to use AHCI Advanced Host Controller Interface AHCI allows the storage driver to enable the advanced Serial ATA features which will increase storage performance Advanced Version 2 17 1249 Copyright C 2015 American Meg...

Страница 38: ...on CPU Q FAN Control Enabled Full Speed Offset 90 CPU Temperature 33 Tcontrol Offset 85 Fan Auto Mode Start Speed Temp 50 CPU Fan Speed N A VCore Voltage 1 005 V 3 3V Voltage 3 309 V 5V Voltage 5 111 V CPU Q FAN Control Enables or disables control of CPU fan speed Full Speed Offset Displays the full speed offset value CPU Temperature Detects and displays the current CPU temperature Tcontrol Offset...

Страница 39: ... Configuration Device Settings Change Settings Serial Port 2 Configuration Device Settings Change Settings HD Audio Enabled Disabled Enabled IO 3F8h IRQ 4 Auto Enabled IO 2F8h IRQ 3 Auto Configure Onboard Devices This section is used to configure the onboard devices Onboard VGA Config Configuration for onboard VGA devices Onboard Audio Enables or disables onboard audio Onboard LAN Device Enables o...

Страница 40: ...ht C 2015 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F7 Discard Changes F9 Optimized Defaults F10 Save Exit ESC Exit Enables or Disables BIOS support for security device O S will not show Security Device TCG EFI protocol and INT1A interface will not be available Trusted Computing TPM Supported Disabled Onboard VGA Config This section is used to config...

Страница 41: ... This section displays the TXE version Power This section is used to configure the power management features APM Configuration Configuration for Advanced Power Management EUP Enables the system to shut down to the lowest possible power state by removing all power to the system board The wake up function will be lost if EUP is enabled Save Exit Advanced Power Security Boot Main Version 2 17 1249 Co...

Страница 42: ...when the system runs in user mode Secure Boot Mode Select this to configure the Secure Boot mode Standard Fixed secure boot policy Custom Changeable Image Execution policy and Secure Boot key databases Boot Boot Device Priority Adjust the boot sequence of the system Boot Option 1 is the first boot device that the system will boot from next will be 2 and so forth Launch CSM This option controls if ...

Страница 43: ...r Security Boot Main Version 2 17 1249 Copyright C 2015 American Megatrends Inc Aptio Setup Utility Copyright C 2015 American Megatrends Inc Select Screen Select Item Enter Select Change Opt F1 General Help F7 Discard Changes F9 Optimized Defaults F10 Save Exit ESC Exit Enable or Disable Full Screen Logo Boot Settings Configuration Full Screen Logo Bootup Num Lock Keyboard Error Message Display Fa...

Страница 44: ...prompted to confirm again before exiting You can also press ESC to exit without saving the changes Load Optimal Defaults To restore the BIOS to default settings select this field then press Enter A dialog box will appear Confirm by selecting Yes Save Exit Advanced Power Security Boot Main Version 2 17 1249 Copyright C 2015 American Megatrends Inc Aptio Setup Utility Copyright C 2015 American Megat...

Страница 45: ...leared 0 WDT Status 1 WDT value is equal to 0 0 WDT value is not equal to 0 SMI Control Register 2 Index F1h Default 00h Bit Description 7 Reserved 6 0 Edge trigger 1 Level trigger 5 3 Reserved 2 This bit is to enable the generation of a SMI due to WDT s IRQ EN_WDT 1 This bit is to enable the generation of a SMI due to CIR s IRQ EN_CIR 0 This bit is to enable the generation of a SMI due to PBD s I...

Страница 46: ...lect 1 62 5ms x WDT Timer out value default 3 5s 0 Determined by WDT Time out value select 1 bit 7 of this register 4 WDT Output through PWRGD Enable 1 Enable 0 Disable During LRESET this bit is selected by JP2 power on strapping option 3 0 Interrupt Level Select for WDT Please refer to Interrupt Level Mapping Table Watchdog Timer Time out Value LSB Register Index 73h Default 38h Bit Description 7...

Отзывы: