Nexans Euromold 200LR Скачать руководство пользователя страница 2

3 x Earthing 

device

6 x Stainless steel 

straps

3 x Semi-

conductive tape

Cable reducer

200CA

Conductor contact 

 

2 hex

Contents :

Elbow

connector housing 

200LR/G

Roll adhesive 

tape

Installation

instructions

Silicone grease 

+ wipers

+

Gloves

Bail restraint

200LRBA

3x

Water sealing 

mastic, type MWS 

IS97082-ENG - 200LR/G

-MT345 - Revision 0

Page 2/9

Содержание Euromold 200LR

Страница 1: ...ndicated in table below Cable reducer size see marking inside cable reducer 200CA 12 200CA 16 13 0 17 5 21 0 25 0 Dia over core insulation mm min max This product should be installed only by competent personnel trained in good safety practices involving high voltage electrical equipment These instructions are not intended as a substitute for adequate training or experience in such safety practices...

Страница 2: ...Cable reducer 200CA Conductor contact 200LRF 200LRMC hex Contents Elbow connector housing 200LR G Roll adhesive tape Installation instructions Silicone grease wipers Gloves Bail restraint 200LRBA 3x Water sealing mastic type MWS IS97082 ENG 200LR G MT345 Revision 0 Page 2 9 ...

Страница 3: ...the cable end a Slightly round off the edge of the core insulation z Remove the extruded conductive screen 4 Cut longitudinal split s in the outer sheath to a point 40 mm from the edge 5 Using a blunt tool make a slight funnel of the outer sheath to fit the earthing device underneath the sheath 6 Install the earthing device underneath the outer sheath protruding for a distance of max 20 mm 7 Cleat...

Страница 4: ...r sealing mastic water sealing mastic adhesive tape solder block on the braid 5 two layers of semi conduc tive tape 5 WATERSEALING earthing device 1 As a protection wrap a few turns of adhesive tape around the conductor end 2 Lubricate the indicated area cable surface and inner surface of the reducer 3 Slide the reducer down the cable 4 Remove the protective adhesive tape from the conductor INSTAL...

Страница 5: ...interface 2 Tighten the contact until the bolt head shears off For 70 95 mm tighten again until the second level of the bolt head shears off 3 After tightening the contact slide the cable reducer up until it butts against the contact Only for 70 95 mm hex SW 5 mm Page 5 9 IS97082 ENG 200LR G MT345 Revision 0 ...

Страница 6: ... contact Insert the threaded end of the pin contact into the mating part and engage threads Take care not to cross threads 5 Tighten with the supplied hex key until the key has taken a set NOTE The hex key must be inserted in the pin contact until it cannot advance any further The hex key is only usable twice once every side cable reducer lubricate pin contact hex key clean thoroughly USE ONLY THE...

Страница 7: ... as close as possible to the connector IMPORTANT NOTES Never disconnect the connector from energised equipment nor energise a disconnected connector without previously installing an appropriate mating part Do not allow hydrocarbon oils or solvents to contaminate the E P D M rubber In the event of contamination wipe the surface clean with a dry cloth 4 Connect earthing lead of the connector and fle...

Страница 8: ...oid sharp edges 8 Apply 2 layers of semi conductive tape 50 stretch 50 overlap as follows start taping on the metal straps ensure the splits are covered up to a point 40 mm behind the outer sheath Without cutting the tape apply a second layer back to the start 9 Remove the core insulation from the conductor for a distance of 30 mm a Using an appropriate solvent thoroughly remove the graphite coati...

Страница 9: ...derneath the outer sheath Have it protruded by maximum 20 mm 8 Cleat the outer sheath using the stainless steel straps Twist straps twice around the cable and fold back the ends to avoid sharp edges 9 Apply 1 layer of semi conductive tape 50 stretch 50 overlap on the metal straps ensure the splits are covered a Remove the core insulation from the conductor for a distance of 30 mm z Slightly round ...