Z-WAVE PLUS INFO
Role type
Node type
Installer icon
User icon
Slave Sleeping report
Z-Wave Plus node
Sensor Notification Device Type (Home Security) Sensor Notification Device Type (Home Security)
AGI (Association Group Information) TABLE
Group
Profile
Command Class & Command (List) N bytes
Group Name(UTF-8)
1
General
Battery Report, Notification Report,
Device Reset Locally
Lifeline
2
Control
Basic Set
PIR Control
BATTERY
Battery report (value)
Description
20–100
Battery Level (%)
0xFF
Low Battery
NOTIFICATION
Event
Type
Event
Event Parameters Length
Event Parameters
The power is applied for the first time
0x08
0x01
0x00
PIR Trigger ON
0x07
0x08
0x00
PIR Trigger OFF
0x07
0x00
0x01
0x08
Tamper switch being press more than 10 seconds
0x07
0x00
0x01
0x03
Tamper switch being press more than 10 seconds and released 0x07
0x03
0x01
VERSION
Protocol Library
Protocol Version
3 (Slave_Enhance_232_Library) 4.3D ( 6.71.01)
MANUFACTURER
Manufacturer ID
Product Type
Product ID
0x0060
0x0001
0x0005
Z-WAVE GROUP
The detector supports either one of two Z-wave Association
Groups.
Group 1: Association with 1 Controller node.
Group 2: Association with 4 nodes (i.e. end devices such as
smart plugs and other lighting controllers). This allows
the detector to transfer commands directly to end
devices without the participation of the controller.
This has the effect that when the detector triggers, all
devices associated with detector will be operated.
Group 1 commands:
• When the unit is powered up and was already a part of a
Z-Wave network, the unit will send a Notification Report to
the node in Group 1.
• When the detector senses a movement, the unit will send
a Notification Report to the nodes of Group 1. Once the
movement is stopped, a Notification Report will be sent again
to Group 1.
• Upon detector status being changed, the unit will check its
battery status simultaneously. When the battery level of the
unit drops to an unacceptable level, the unit will emit Battery
report to the nodes of Group 1.
• When performing Factory Reset the unit will send Device
Reset Locally Notification to the node of Group1.
Group 2 commands:
• When the detector is triggered, the unit will send BASIC_SET
command which contains a value to the nodes of Group 2.
COMMAND CLASSES
The module supports Command Classes including:
• COMMAND_CLASS_ZWAVEPLUS_INFO_V2
• COMMAND_CLASS_ASSOCIATION_V2
• COMMAND_CLASS_ASSOCIATION_GRP_INFO
• COMMAND_CLASS_TRANSPORT_SERVICE_V2
• COMMAND_CLASS_VERSION_V2
• COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
• COMMAND_CLASS_DEVICE_RESET_LOCALLY
• COMMAND_CLASS_POWERLEVEL
• COMMAND_CLASS_SECURITY
• COMMAND_CLASS_SECURITY_2
• COMMAND_CLASS_SUPERVISION
• COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
• COMMAND_CLASS_BATTERY
• COMMAND_CLASS_WAKE_UP_V2
• COMMAND_CLASS_NOTIFICATION_V4
WAKEUP COMMAND CLASS
After it has been included into a Z-wave network, the detector
will go to sleep but will send a Wakeup Notification Command
periodically at preset period to the controller. The Motion detector
will stay awake for 10 seconds at least and then go back to sleep
to conserve battery life.
The time interval between Wakeup Notification Commands can
be set in the Wakeup Command Class based on the range values
below:
Minimum Wake Up Interval
600 s (10 minutes)
Maximum Wake Up Interval
86400 s (1 day)
Default Wake Up Interval
14400 s (4 hours)
Wake Up Interval Step Seconds
600 s (10 minutes)
PROGRAMMING
(only in english)
2
0
10
6
(m)
100°
4
8
2 m
0
2
4
6
8
10 m
2
4
6
8
10
2
0
10
6
(m)
100°
4
8
2 m
0
2
4
6
8
10 m
2
4
6
8
10
Batteri
Battery
Bakstycke
Back cover
Sabotagelarm
Tamper switch
Aktiveringstimer
Timer
Ljuskänslighet
Lux knob
Rörelsesensor
Motion sensor
LED indikator
LED indicator
DETEKTERINGSOMRÅDE /
PIR PATTERN
Ovanifrån / Top view
Från sidan / Side view
SP-816 MANUAL 2017