Z-WAVE PLUS INFO

Role type

Node type

Installer icon

User icon

Slave Sleeping report

Z-Wave Plus node

Sensor Notification Device Type (Home Security) Sensor Notification Device Type (Home Security)

AGI (Association Group Information) TABLE

Group

Profile

Command Class & Command (List) N bytes

Group Name(UTF-8)

1

General

Battery Report, Notification Report, 
Device Reset Locally 

Lifeline

2

Control

Basic Set

PIR Control

BATTERY

Battery report (value)

Description

20–100

Battery Level (%)

0xFF

Low Battery

NOTIFICATION

Event

Type

Event

Event Parameters Length

Event Parameters

The power is applied for the first time 

0x08

0x01

0x00

PIR Trigger ON

0x07

0x08

0x00

PIR Trigger OFF

0x07

0x00

0x01

0x08

Tamper switch being press more than 10 seconds

0x07

0x00

0x01

0x03

Tamper switch being press more than 10 seconds and released 0x07

0x03

0x01

VERSION

Protocol Library

Protocol Version

3 (Slave_Enhance_232_Library) 4.3D ( 6.71.01)

MANUFACTURER

Manufacturer ID

Product Type

Product ID

0x0060

0x0001

0x0005

Z-WAVE GROUP 
The detector supports either one of two Z-wave Association 
Groups.
Group 1: Association with 1 Controller node.
Group 2: Association with 4 nodes (i.e. end devices such as 

smart plugs and other lighting controllers). This allows 
the detector to transfer commands directly to end 
devices without the participation of the controller. 
This has the effect that when the detector triggers, all 
devices associated with detector will be operated.

Group 1 commands:
•   When the unit is powered up and was already a part of a 

Z-Wave network, the unit will send a Notification Report to 
the node in Group 1.

•  When the detector senses a movement, the unit will send 

a Notification Report to the nodes of Group 1. Once the 
movement is stopped, a Notification Report will be sent again 
to Group 1.

•  Upon detector status being changed, the unit will check its 

battery status simultaneously. When the battery level of the 
unit drops to an unacceptable level, the unit will emit Battery 
report to the nodes of Group 1.

•  When performing Factory Reset the unit will send Device 

Reset Locally Notification to the node of Group1.

Group 2 commands:
•  When the detector is triggered, the unit will send BASIC_SET 

command which contains a value to the nodes of Group 2.

COMMAND CLASSES
The module supports Command Classes including:
• COMMAND_CLASS_ZWAVEPLUS_INFO_V2
• COMMAND_CLASS_ASSOCIATION_V2
• COMMAND_CLASS_ASSOCIATION_GRP_INFO
• COMMAND_CLASS_TRANSPORT_SERVICE_V2
• COMMAND_CLASS_VERSION_V2
• COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
• COMMAND_CLASS_DEVICE_RESET_LOCALLY
• COMMAND_CLASS_POWERLEVEL
• COMMAND_CLASS_SECURITY
• COMMAND_CLASS_SECURITY_2
• COMMAND_CLASS_SUPERVISION
• COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4
• COMMAND_CLASS_BATTERY
• COMMAND_CLASS_WAKE_UP_V2
• COMMAND_CLASS_NOTIFICATION_V4

WAKEUP COMMAND CLASS
After it has been included into a Z-wave network, the detector 
will go to sleep but will send a Wakeup Notification Command 
periodically at preset period to the controller. The Motion detector 
will stay awake for 10 seconds at least and then go back to sleep 
to conserve battery life.

The time interval between Wakeup Notification Commands can 
be set in the Wakeup Command Class based on the range values 
below: 

Minimum Wake Up Interval

600 s (10 minutes)

Maximum Wake Up Interval

86400 s (1 day)

Default Wake Up Interval

14400 s (4 hours)

Wake Up Interval Step Seconds

600 s (10 minutes)

PROGRAMMING 

(only in english)

2

0

10

6

(m)

100°

4

8

2 m

10 m

2

4

6

8

10

2

0

10

6

(m)

100°

4

8

2 m

10 m

2

4

6

8

10

Batteri
Battery

Bakstycke
Back cover

Sabotagelarm
Tamper switch

Aktiveringstimer
Timer

Ljuskänslighet
Lux knob

Rörelsesensor
Motion sensor

LED indikator
LED indicator

DETEKTERINGSOMRÅDE /
PIR PATTERN

Ovanifrån / Top view

Från sidan / Side view