Instructions for use, installation and connection
16
Remove the fixing screws from the
polythene bag on the top of the
appliance, but leave the appliance in the
base tray packaging until you are ready
to install it.
Note:
When removing the appliance
from the base tray packaging care
should be taken not to damage the
appliance.
1. When installing in a typical 600mm
deep, built in housing unit, the false
back should be removed from the
housing unit to provide the necessary
depth for installation.
2. When the false back is removed, it is
normally the case that the support
shelf for the appliance leaves a gap
between the back edge and the wall
of approximately 80mm.
3. If no gap occurs between the back
edge of the shelf and the wall behind
the unit, we recommend that a gap of
at least 30mm is made by shortening
the shelf.
Front
of oven
Back edge of
support shelf
30-80
mm
12mm
gap
Rear
Wall
The appliance is designed to fit into a
standard 600mm wide housing unit, with
minimum internal dimensions as shown.
Note: 590mm is to the underside of the
worktop when the appliance is built
under, or to the underside of the panel
above, when the appliance is installed
into a tall housing unit. Please note that
all sizes are nominal, and some variation
is to be expected.
Installing appliance under a
worktop
Where the appliance is installed under a
worktop, with a hob installed above it, the
installation instructions for the hob must
be read in conjunction with these
instructions
Step 2: Connect to the electricity
supply
We recommend that the appliance is
connected by a qualified electrician, who
is a member of the N.I.C.E.I.C. and who
will comply with the I.E.E. and local
regulations.
Important:
Ensure that you route all mains
electrical cables well clear of any adjacent
heat source, such as an oven or grill.
Warning:
This appliance must be
earthed.
1. Where a fixed connection is used, a
device allowing the appliance to be
isolated on all poles from the mains
supply with a contact opening width of
at least 3mm must be provided.
Use a 13 amp fuse.
2. A type HO5 V V-F cable must be
used as the mains lead. The cross
section must be 2.5mm2.
3. The mains terminal block is
positioned at the right hand rear of
the top service panel.
5. Connect the cable to the terminal
block, and tighten the cable clamp.
6. Close the terminal box, ensuring that
the cover is engaged on the locking
tabs.