13.140
CONNECT TO THE ELECTRICITY SUP-
PLY
Warning:
This appliance must be earthed.
This appliance is not intended to be oper-
ated by means of an external timer or
separate remote control system.
The appliance must be installed by a
competent electrician using a double
pole control unit of 32 ampere minimum
capacity with 3mm minimum contact
separation at all poles.
We recommend that the appliance is con-
nected by a competent person who is a
member of a competent persons scheme.
1.
Access to the mains terminal
is gained by opening the terminal block
cover at the rear of the appliance (use a
small flat-bladed screwdriver).
2.
Connection should be made with
6.0mm2 flexible twin and earth cable.
3.
First strip the wires, then push
the cable through the cable clamp in the
terminal block cover.
4.
Connect the cable to the
terminal block and tighten the cable
clamp screw (see diagram).
5.
Close the terminal box, ensuring
that the cover is engaged on the locking
tabs.
Your appliance will be fitted with one of
the two terminal blocks below, Block A,
Block B
INSTALLATION INSTRUCTIONS