background image

Before you start: 

Please read the

instructions.  Planning your installation will
save you time and effort.
Prior to installation, ensure that the local
distribution conditions (nature of the gas and
gas pressure) and the adjustment of the
appliance are compatible.  The adjustment
conditions are stated on the data badge.
This appliance is not connected to a combustion
evacuation device.  It shall be installed and
connected in accordance with current
installation regulation.  Particular attention
shall be given to the relevant requirements
regarding ventilation.
In your own interest and that of safety, it is
the law that all gas appliances be installed
and serviced by competent persons.
CORGI registered installers undertake to
work to satisfactory standards.
Where regulations or standards have been
revised since this handbook was printed,
always use the latest edition.

In the UK the regulations and
standards are as follows:

1. Gas Safety Regulations 1996

(Installation and Use).

2. Building Regulations - Issued by the

Department of the Environment.

3. Building Standards (Scotland)

(Consolidated) - Issued by the Scottish
Development Department.

4. The current I.E.E. Wiring Regulations.
5. Electricity at Work Regulations 1989.
6. BS 6172 Installation of Domestic Gas

cooking Appliances
Also, for 

LP Gas

, refer to BS 5482

Part 1, Part 2 or part 3 as relevant.

7. Installation & Servicing Instructions for

this appliance.

For installation in countries other than the
UK, the appliance must be connected in
accordance with all local gas and electrical
regulations.  In the Republic of Ireland,
Installers should refer to IS813 Domestic
Gas Appliances.

Ventilation Requirements 

The room containing the appliance should
have an air supply in accordance with
BS 5440: Part 2: 1989:

All rooms require an openable window,
or equivalent, and some rooms will
require a permanent vent as well.

For room volumes up to 5m

3

an air

vent of 100cm

2

is required.

If the room has a door that opens directly
to the outside, or the room exceeds
10m

3

, NO AIR VENT is required.

For room volumes between 5m

3

and

10m

3

an air vent of 50cm

2

is required.

If there are other fuel burning appliances
in the same room, BS 5440: Part 2:
1989 should be consulted to determine
the air vent requirements.

This appliance must not be installed in
a bed sitting room of less than 20m

3

or

in a bathroom or shower room.

Windows and permanent vents should
therefore not be blocked or removed without
first consulting a CORGI gas installer.

LP Gas only - 

Do not install this appliance

in a room below ground level.  This does
not preclude installation into rooms which
are basements with respect to one side of
the building, but open to ground level on
the opposite side.
In the Republic of Ireland, refer to relevant Irish
Standards for correct ventilation requirements.

Failure to install appliances correctly is
dangerous and could lead to prosecution.

20

INSTALLATION INSTRUCTIONS

9

USING THE GRILL

Caution: Accessible parts may
be hot when the grill is used.
Young children should be kept
away.

The grill is a variable electric dual grill.

To switch on the grill

Open the grill door.
Turn the grill control knob either clock-
wise to use the full grill settings, or anti-
clockwise to the economy grill settings.
The economy grill settings only use the
inner element of the grill.

Important:

Keep the grill door open

when the grill is on.
To switch off, return the control knob to
the “off” position.

Preheating

For best cooked results, always
preheat the grill for about 3 minutes.

The cooling fan

When the grill is switched on, you will
hear the cooling fan come on - this
keeps the fascia and control knobs of
the appliance cool during grilling
only.  The fan will continue to operate
for a period after the grill control has
been switched off.  Should any fault
occur with the cooling fan, the
appliance will require servicing -
contact Customer Support.

Detachable grill pan handle

Place the handle over the edge of the
grill pan, at the narrow side edges.
Slide the handle to the centre, and
locate between the handle position
indicators.  

The handle should be removed from
the pan during grilling, to prevent
overheating.
The handle is designed for removing /
inserting the grill pan under the grill
when grilling.  
If cleaning the grill pan when it is hot,
use oven gloves to move it.  

Do not

use

the handle to pour hot fats from the
grill pan.
Food for grilling should be positioned
centrally on the trivet.

handle

grill pan

trivet

handle position

indicators

Содержание Classic 110DF

Страница 1: ...Stoney Lane Prescot Merseyside L35 2XW 08 25223 00 4 2003 d Classic 110DF 110cm Dual Fuel Range Cooker For Natural Gas models User Installation Instructions...

Страница 2: ...ll find the telephone number is your local telephone directory under Gas If you smell gas Do not try to light any appliance Do not touch any electrical switch Call the Gas Emergency Helpline at TRANSC...

Страница 3: ...the above details Model No and Serial No to hand when calling New World Customer Care They are essential to booking your call Outside the UK and Northern Ireland refer to your local supplier Model No...

Страница 4: ...f its features and benefits Your appliance is designed to be installed free standing or flush to base units Ventilation The use of a gas cooking appliance results in the production of heat and moistur...

Страница 5: ...ity supply is switched on at the socket Check that the gas supply is switched on Before using the appliance for the first time remove any protective polythene film and wash the oven shelves and furnit...

Страница 6: ...tored in the drawer Do not store items with plastic or wooden handles in the drawer as they may be damaged by heat from the oven Do not store flammable liquids even when cold in the storage drawer as...

Страница 7: ...any other purpose Remove all packaging from the appliance before using for the first time Make sure you read and under stand the instructions before using the appliance Keep electrical leads short so...

Страница 8: ...is being used The appliance is fitted with a switch back system which will automatically turn off the hotplate controls if they are inadvertently left on as the lid is closed The lid is not intended t...

Страница 9: ...ING THE HOB Pans For optimum safety and performance we recommend the use of flat bottomed pans with a base diameter of minimum 100mm 4 and maximum 250mm 10 Turn pan handles to a safe position so they...

Страница 10: ...ll flame symbol The griddle is now ready for cooking Do not use metal implements as they may damage the non stick surface After cooking allow the griddle to cool before moving or cleaning it 8 21 INST...

Страница 11: ...pliances in the same room BS 5440 Part 2 1989 should be consulted to determine the air vent requirements This appliance must not be installed in a bed sitting room of less than 20m3 or in a bathroom o...

Страница 12: ...the grill pan eg when cooking whole fish or browning dishes such as cauliflower cheese Push the grill pan to the back of the shelf to position it under the centre of the grill Never allow fat to buil...

Страница 13: ...dishwasher After cleaning dry thoroughly then re season the cooking surface by wiping sparingly with a minimum amount of unsalted vegetable oil and store in a dry place Note that olive oil is unsuit a...

Страница 14: ...ining bleach coarse wire wool or any hard implements as they will damage the surfaces All user accessible parts of the appliance can be safely cleaned with a clean cloth wrung out in hot soapy water V...

Страница 15: ...eg 12 00 A Auto symbol goes out cookpot symbol comes on To select an alarm tone Press the minus button to listen to the first tone Release the minus button and press it again to listen to the second...

Страница 16: ...ooking time left on the clock before the alarm sounds press the cook time and ready time buttons simultaneously 4 A U T O A U T O A U T O PROGRAMMER CLOCK 15 5 A Auto symbol appears 6 The cookpot symb...

Отзывы: