Страница 2: ...ls in or under this appliance e g aerosols Do not allow pots to boil dry as damage to both pan and cooktop may result Do not operate the cooktop for an extended period of time without a pot or pan on the hotplate Do not allow large cookware to overhang the cooktop onto the adjacent benchtop This will cause scorching to the benchtop surface Do not allow cooking pots or pans to intrude into the area...

Страница 3: ...rks to all burners To light a burner depress the corresponding knob and turn to the High position while depressing the knob The knob may be released once the flame is established Flame safeguard models The knob must be turned to the High position then pushed down as far as possible for approximately 5 seconds If the flame goes out when the knob is released simply depress the knob again this time h...

Страница 4: ...corresponds to the burner you want to light Port blockage in ignition area Ensure that ports in ignition area are clean and dry Ignition spark plugs wet or dirty Dry or clean ignition spark plugs No spark is obtained when control knob is activated Electricity supply is disconnected or switched off Switch on electricity or check fuses Ignition spark plugs wet or dirty Dry or clean ignition spark pl...

Страница 5: ...ase where the base of the cooktop is accessible from below i e inside a cupboard etc An impression has been incorporated into the base to ensure a minimum clearance of 15mm is maintained between the base and the barrier This barrier may be made of any non combustible rigid material 4 Fitting the cooktop into the bench Carry out as follows Place the seals supplied around the bench cut out as shown ...

Страница 6: ...pressure should not vary from the nominal outlet pressure of 1 00kPa by more than 0 20kPa Regulator An appliance regulator is provided The regulator must be positioned so that the pressure test nipple is accessible when the appliance is installed Connect the gas supply to the B S P internal thread inlet of the regulator Refer to bench cutout Figure 4 for connection point position Assembly of Regul...

Страница 7: ...nd the injector hole blanked off for several seconds 7 The operation of the regulator can be confirmed by connecting a manometer to the pressure test point located on the side of the regulator body adjacent to the outlet With the appliance operating check the outlet pressure when all burners of the appliance are operating at maximum when the smallest burner of the appliance is operating at minimum...

Страница 8: ...anty Period Electrolux or its ASC will at no extra charge if your Appliance is readily accessible for service without special equipment and subject to these terms and conditions repair or replace any parts which it considers to be defective Electrolux or its ASC may use remanufactured parts to repair your Appliance You agree that any replaced Appliances or parts become the property of Electrolux T...

Страница 9: ...nsion and installation information call into your retailer phone or email our customer care team or visit our website TOP SERVICE Top Service encompasses the after sales service provided by The Electrolux Group to consumers including delivery home service and spare parts Westinghouse We are part of the Electrolux family Share more of our thinking at www electrolux com Part number 305 4423 02 Rev D...