5 Settings
5.1
CONTROLS
The
CONTROL
settings tab contains settings related to remote head control/steering. For every axis
there is a setting for the max speed, ease in/out, inverting the axis, dead-band and exponential.
The
CONTROL
tab also allows enabling or disabling the manual pan axis trim.
Figure 5.1: Newton C1 Settings - Control tab
Table 5.1: Newton C1 Settings - Control tab
Setting
Range
Description
MAX SPEED
45
°
/
s
–
360
°
/
s
Maximum speed for axis
EASE IN/OUT
20
–
500
Maximum ease in/out for axis
MODE
NORMAL
INVERTED
Axis invert
DEADBAND
0
% –
100
%
Axis dead-band in percent
EXPO
−
100
% –
100
%
Axis exponential in percent
PANTRIM
ENABLE
DISABLE
Activate manual compensation of drift in
pan axis. Amount of trim can be adjusted
ZOOM DESENSE
ENABLE
DISABLE
Activate zoom-based desensitation
ZOOM DESENSE MAX
1
-
100
Set the max zoom-based desensitiation