Newtec 3X00 Modem Guide

 

 

                 8 

 

3.

 

Configuration 

 

Core Configuration Items 

3.1.

1.

 

Access the AAQ Remote GUI and login to the AAQ. 

2.

 

Go to View 

 Configuration under core tab and search for “Newtec” 

3.

 

Change the “Newtec Module Open AMIP Port” to the desired value (or leave as default: 5001) 

 

Path

 

Main Window → View 

 Configuration 

Core 

Level 4 

 
 

 

Figure 7 - Configuration Core 

 

Long Name 

Level 

Type 

Value 

Range 

Description 

Newtec Module 
Open AMIP Port 

Integer 

0 - 

65535 

The port to use when connecting to the 
Newtec Module  (default: 5001) 

Newtec Com Port 

String 

This config item is not used for this module. 

Newtec Com Port 
Settings 

Integer 

This config item is not used for this module. 

Newtec Gradient 
Sample Time 

Integer 

0-300 

Sample time in seconds for detecting signal 
gradient (default: 2) 

Newtec Noise Sample 
Time 

Integer 

0-60000 

Sample time in MS for detecting signal noise 
(default: 1000) 

 

Содержание 3 00 Series

Страница 1: ...ence Guide Revision R11 9 0 Documentation of the interface between the Newtec 3X00 modem router and the AvL Technologies AAQ antenna controller reference information and troubleshooting guide Appendix...

Страница 2: ...ig items Contents 1 Introduction 2 2 Setup Guide 3 Hardware 3 2 1 Software 5 2 2 Hardware Connection 5 2 3 2 3 1 Serial Communication Connection 5 2 3 2 Ethernet Communication Connection 5 2 3 3 Newte...

Страница 3: ...re 8 Target Profile 9 Figure 9 Command Window 10 Figure 10 Sensor Output 10 Figure 11 Device Window 11 1 Introduction The Newtec modem has receive and transmit capabilities allowing for satellite comm...

Страница 4: ...Power LED Blue continuous when powered up 2 RX Indicator LED Blue continuous forward satellite signaling receiving 3 TX Indicator LED Blue blinking traffic transmitting via the satellite link 4 Warnin...

Страница 5: ...cable 5 Fan connector Connection for the optional fan kit For future use not yet supported 6 Gigabit Ethernet cable connectors Connection for the LAN type RJ 45 Ethernet cable Left LED orange continuo...

Страница 6: ...3 1 Serial Communication Connection A serial connection is not an option for the hardware associated with this module 2 3 2 Ethernet Communication Connection When setting the system to communicate by...

Страница 7: ...modem has a static IP Address that allows for communication The AAQ controller must be configured to be on the same network as the modem Additionally the Customer Network 2 IP address of the AAQ contr...

Страница 8: ...t the AAQ Network Interface Options button Figure 5 Enter an IP address in the Customer Network 2 box that is on the same network as the modem s default IP address In this example an IP address of 192...

Страница 9: ...nfiguration Core Long Name Level Type Value Range Description Newtec Module Open AMIP Port 4 Integer 0 65535 The port to use when connecting to the Newtec Module default 5001 Newtec Com Port 4 String...

Страница 10: ...me Item Level Type Value Range Description Scan Source 1 Choice Signal source used when acquiring on a satellite Coarse Source 1 Choice Source used for coarse peaking on a signal Fine Source 1 Choice...

Страница 11: ...llite and perform coarse and fine peaking If not configured to use a reference satellite the antenna will go to the elevation of the target satellite and perform an azimuth raster scan looking for a m...

Страница 12: ...em Newtec Signal Average Readout of average signal as read from AAQ Newtec Signal Gradient Mathematical approximation of signal change over time in coordination with Newtec Gradient Sample Time config...

Страница 13: ...n Window View Device Window Insure that correct AAQ remote ROM and Module versions are loaded See Figure 3 Version Info Check that IP addresses are connected to the same network Review Sections 2 3 2...

Отзывы: