ALWAYS wear appropriate personal protective equipment when operating the unit
!
AeroVent® 3X Manual / 4721.0117
Page 5 of
7
MAINTENANCE
ITEM
CHECK
ACTION
Lid Gasket 10004249
Before each use
Replace As Necessary
Safe2Vent
™
Element (2 pack) 10004703 Monthly
Replace Every 90 days or 600 cans, more
often for full cans
Cobalt Point (3) 10003377
Before each use
Replace As Necessary
Bellows (3) 10003791
Every 180 days
Replace As Necessary
Trough Grommet (3) 10001874
Before each use
Replace As Necessary
Operating Handle 10003909
Before each use
Lubricate regularly with light oil.
(3-in-1, WD-40 etc.)
COBALT POINT REPLACEMENT
(See Assembly Drawing Page 3)
HELPFUL HINT:
Leave the unit mounted on the drum to replace the cobalt points.
1.
Open the lid and remove the left and right shrouds including the grounding cable.
2.
Remove the four bolts that secure the bellows flange to the base from underneath the unit. There is no need to
loosen any of the bellows clamps, unless the bellows are damaged and need to be replaced.
3.
Rotate the trough assembly upward and allow it to rest against the lid.
NOTE
: The bellows flange may have to be gently pried off of the flange gasket to rotate the assembly up.
4.
Loosen the (3) set-screws with a 5/16” wrench and replace the points. Tighten the bolts against the new points.
5.
Re-assemble the unit in the reverse order of the steps above.
NOTE: Do not forget to install the grounding cable.
Safe2Vent™ Dual
Filter w/ Manifold
Front Support
Foot
Lid Gasket
Operating
Handle
Trough Liner
Trough Liner
Grommet
Front
Panel
Rear Support
Foot