Warranty

All Products from NEWPORT ELECTRONICS, INC. are warranted
against defective material and workmanship for a period of one (1)
year from the date of delivery.

If the unit should malfunction, it must be returned to the factory for
evaluation. NEWPORT’s Customer Service Department will issue an
Authorized Return (AR) number immediately upon phone or written
request. Upon examination by Newport, if the unit is found to be
defective it will be repaired or replaced at no charge. However, this
WARRANTY is VOID if the unit shows evidence of having been
tampered with or shows evidence of being damaged as a result of
excessive corrosion; or current, heat, moisture or vibration; improper
specification; misapplication; misuse or other operating conditions
outside of NEWPORT’s control. Components which wear or which are
damaged by misuse are not warranted. These include contact points,
fuses, and triacs.

In addition to NEWPORT’s standard warranty period, NEWPORT
ELECTRONICS will extend the warranty period for one (1) additional
year only if the warranty card enclosed with each instrument is
returned to NEWPORT.

Newport is glad to offer suggestions on the use of its various
products. Nevertheless, NEWPORT warrants only that the parts
manufactured by it will be as specified and free of defects.
NEWPORT MAKES NO OTHER WARRANTIES OR REPRESENT-
ATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED,
EXCEPT THAT OF TITLE, AND ALL IMPLIED WARRANTIES
INCLUDING ANY WARRANTY OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY
DISCLAIMED. LIMITATION OF LIABILITY: The remedies of
purchaser set forth herein are exclusive and the total liability of
NEWPORT with respect to this order, whether based on contract,
warranty, negligence, indemnification, strict liability or otherwise,
shall not exceed the purchase price of the component upon
which liability is based. In no event shall NEWPORT be liable for
consequential, incidental or special damages.

Every precaution for accuracy has been taken in the preparation of
this manual; however, NEWPORT neither assumes responsibility for
any omissions or errors that may appear nor assumes liability for any
damages that result from the use of the products in accordance with
the information contained in the manual.

SPECIAL CONDITIONS: Should this equipment be used in any
nuclear installation or activity, purchaser will indemnify NEWPORT
and hold NEWPORT harmless from any liability or damage
whatsoever arising out of the use of the equipment in such a manner. 

Return Requests

Direct all warranty and repair requests/inquiries to the NEWPORT
Customer Service Department. BEFORE RETURNING ANY
PRODUCTS(S) TO NEWPORT, PURCHASER MUST OBTAIN AN
AUTHORIZED RETURN (AR) NUMBER FROM NEWPORT’S
CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be
marked on the outside of the return package and on any
correspondence.

The purchaser is responsible for shipping charges, freight, insurance
and proper packaging to prevent breakage in transit. NEWPORT’s
warranty does not apply to defects resulting from action of the buyer,
mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification.

FOR 

WARRANTY 

RETURNS,

please have the following infor-
mation available BEFORE con-
tacting NEWPORT:
1. P.O. number under which

the product was PUR-
CHASED,

2. Model and serial number of

the product under warranty,
and

3. Repair instructions and/or

specific problems relative to
the product.

FOR 

NON-WARRANTY

REPAIRS, consult NEWPORT
for current repair charges. Have
the following information avail-
able BEFORE contacting NEW-
PORT:
1. P.O. number to cover the

COST of the repair,

2. Model and serial number of

product, and

3. Repair instructions and/or

specific problems relative to
the product.

Содержание PHH-60

Страница 1: ...PHH 60 4 39 ON OFF PH S S pH CONDUCTIVITY METER PHH 60 PHH 80 pH Conductivity Meter Operator s Manual Newport Electronics Inc...

Страница 2: ...may be covered by one or more of the following patents United States Patents Des 336 895 5 274 577 France Brevet No 91 12756 Spain 2039150 United Kingdom Patent No 2248954 and other international pate...

Страница 3: ...e purchase price of the component upon which liability is based In no event shall NEWPORT be liable for consequential incidental or special damages Every precaution for accuracy has been taken in the...

Страница 4: ...te Broughton Astley Leicestershire England LE9 6TU TEL 44 1455 285998 FAX 44 1455 285604 Newport Electronics B V Postbus 8034 1180 LA Amstelveen The Netherlands TEL 31 20 6418405 FAX 31 20 6434643 New...

Страница 5: ...n 5 Calibrating the Meter 6 pH Mode 6 Conductivity Mode 7 Section 6 Operating Procedure 7 Section 7 pH Electrode Care 8 Section 8 pH Electrode Replacement 9 Section 9 Conductivity Electrode Care 10 Se...

Страница 6: ...he shipping agent The carrier will not honor any claims unless all shipping material is saved for their examination After examining and removing contents save packing material and carton in the event...

Страница 7: ...conductivity capability to 199 999 mhos While in use the electrodes fold out and lock into a 90 or 180 position When testing is completed the electrodes fold back into the instrument case Recessed sw...

Страница 8: ...ge the battery do the following 1 Insert your thumb in the recessed area of the battery compartment door and pull it away from the display 2 Snap the 9V alkaline battery into the battery clip 3 Place...

Страница 9: ...e pH Electrode Fig 3 To remove the soaker bottle 1 Extend the electrode pair to the 90 position 2 Hold part of the electrode shafts and the white cap with one hand 3 With the thumb and forefinger of t...

Страница 10: ...pping the electrode in pH7 solution to avoid contamination Cross contamination of calibration standards will cause the appearance of drift in the instrument pH Mode For best results calibrate pH with...

Страница 11: ...djust SPAN pot to desired conductivity value 6 Rinse electrodes and return to storage compartment Operating Procedure The 9 volt battery should already be installed 1 Extend electrode pair to either t...

Страница 12: ...back fill the bottle with a small amount of pH4 buffer or pH7 buffer 9 Remove the battery when the instrument is to be stored for a long period of time pH Electrode Care pH Electrodes must be kept moi...

Страница 13: ...ailable from NEWPORT Engineering part number PHE 8200 To remove the electrode simply unscrew it clockwise from the electrode pivot hinge on the meter You will hear a pop that s OK Refer to Figure 4 Fi...

Страница 14: ...both conductance rings One ring is located at the bottom of the electrode and the other is located approximately 1 up from the bottom above the blue collar 4 Twist the brush and scrub up and down for...

Страница 15: ...tion and prevents it from drying out The red cap on the conductivity electrode prevents fluid from entering the electrode when only pH is being measured and reduces the need for cleaning Clean both el...

Страница 16: ...10 0 9 0 8 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 0 0 LIME SODA SOFTENING SALT WATER AQUARIUM SWIMMING POOL WATER FRESH WATER AQUARIUM BREWING PROCESS NICKEL PLATING FOOD PROCESSING PICKLE PROCESSING EXTREMEL...

Отзывы: