background image

Maintenance

Handling

DO NOT lay instrument on display with
wet electrode since the liquid may enter
the instrument case through the base of
the electrode creating a short or circuit
board damage.  Shake the instrument
vigorously after each use to remove ALL
water from the side of the pH electrode
and inside of the conductivity electrode.

Cleaning

Both electrodes are equipped with
protective caps.  The bottle on the pH
electrode protects the glass bulb inside
the plastic sleeve , protects it from
contamination and prevents it from
drying out.  The red cap on the
conductivity electrode prevents fluid
from entering the electrode when only
pH is being measured and reduces the
need for cleaning.  Clean both electrodes
before storing to prevent build-up of
sediment and to assure long life.

Specifications

pH

Range:

0 to 14

Accuracy:

±0.01 pH

Temperature 

Compensation:

Automatic 0° to 70°C

Conductivity

Range

PHH-60:

0 to 19,999 µmhos

PHH-80:

0 to 1,999; 

0 to 19,999;

0 to 199,999 µmhos

Resolution:

10 ppm or 10 µmhos

Accuracy:

±2% of span

Temperature 

Compensation:

Automatic 0° to 50°C

Power:

9V alkaline battery

Dimensions:

6

1

4

” x 1

1

4

” x 2

1

4

(158.75 x 31.75 x 57.15 mm)

Weight:

8.5 oz (241 g)

PHH-60 and PHH-80

pH/Conductivity Meter

11

Содержание PHH-60

Страница 1: ...PHH 60 4 39 ON OFF PH S S pH CONDUCTIVITY METER PHH 60 PHH 80 pH Conductivity Meter Operator s Manual Newport Electronics Inc...

Страница 2: ...may be covered by one or more of the following patents United States Patents Des 336 895 5 274 577 France Brevet No 91 12756 Spain 2039150 United Kingdom Patent No 2248954 and other international pate...

Страница 3: ...e purchase price of the component upon which liability is based In no event shall NEWPORT be liable for consequential incidental or special damages Every precaution for accuracy has been taken in the...

Страница 4: ...te Broughton Astley Leicestershire England LE9 6TU TEL 44 1455 285998 FAX 44 1455 285604 Newport Electronics B V Postbus 8034 1180 LA Amstelveen The Netherlands TEL 31 20 6418405 FAX 31 20 6434643 New...

Страница 5: ...n 5 Calibrating the Meter 6 pH Mode 6 Conductivity Mode 7 Section 6 Operating Procedure 7 Section 7 pH Electrode Care 8 Section 8 pH Electrode Replacement 9 Section 9 Conductivity Electrode Care 10 Se...

Страница 6: ...he shipping agent The carrier will not honor any claims unless all shipping material is saved for their examination After examining and removing contents save packing material and carton in the event...

Страница 7: ...conductivity capability to 199 999 mhos While in use the electrodes fold out and lock into a 90 or 180 position When testing is completed the electrodes fold back into the instrument case Recessed sw...

Страница 8: ...ge the battery do the following 1 Insert your thumb in the recessed area of the battery compartment door and pull it away from the display 2 Snap the 9V alkaline battery into the battery clip 3 Place...

Страница 9: ...e pH Electrode Fig 3 To remove the soaker bottle 1 Extend the electrode pair to the 90 position 2 Hold part of the electrode shafts and the white cap with one hand 3 With the thumb and forefinger of t...

Страница 10: ...pping the electrode in pH7 solution to avoid contamination Cross contamination of calibration standards will cause the appearance of drift in the instrument pH Mode For best results calibrate pH with...

Страница 11: ...djust SPAN pot to desired conductivity value 6 Rinse electrodes and return to storage compartment Operating Procedure The 9 volt battery should already be installed 1 Extend electrode pair to either t...

Страница 12: ...back fill the bottle with a small amount of pH4 buffer or pH7 buffer 9 Remove the battery when the instrument is to be stored for a long period of time pH Electrode Care pH Electrodes must be kept moi...

Страница 13: ...ailable from NEWPORT Engineering part number PHE 8200 To remove the electrode simply unscrew it clockwise from the electrode pivot hinge on the meter You will hear a pop that s OK Refer to Figure 4 Fi...

Страница 14: ...both conductance rings One ring is located at the bottom of the electrode and the other is located approximately 1 up from the bottom above the blue collar 4 Twist the brush and scrub up and down for...

Страница 15: ...tion and prevents it from drying out The red cap on the conductivity electrode prevents fluid from entering the electrode when only pH is being measured and reduces the need for cleaning Clean both el...

Страница 16: ...10 0 9 0 8 0 7 0 6 0 5 0 4 0 3 0 2 0 1 0 0 0 LIME SODA SOFTENING SALT WATER AQUARIUM SWIMMING POOL WATER FRESH WATER AQUARIUM BREWING PROCESS NICKEL PLATING FOOD PROCESSING PICKLE PROCESSING EXTREMEL...

Отзывы: