Family of Brands
– ILX Lightwave
®
• New Focus™ • Ophir
• Corion • Richardson Gratings™ • Spectra-Physics
QSOPS-A, Rev A 02/25/2016
s
Oriel
Arc Lamp
Power Supplies
Quick Start Guide
OPS-A150, OPS-A500
Страница 1: ...Family of Brands ILX Lightwave New Focus Ophir Corion Richardson Gratings Spectra Physics QSOPS A Rev A 02 25 2016 s Oriel Arc Lamp Power Supplies Quick Start Guide OPS A150 OPS A500...
Страница 2: ...ATION MODE 17 5 2 CURRENT OPERATION MODE 20 6 OPS A SERIES OVERVIEW 22 CONTACTING ORIEL INSTRUMENTS 23 LIST OF FIGURES Figure 1 OPS A Power Supply Front Panel Connections 9 Figure 2 OPS A Power Supply...
Страница 3: ...dling could result in irreparable damage to the equipment and personal injury or death EUROPEAN UNION CE MARK The presence of the CE Mark on Newport Corporation equipment means that it has been design...
Страница 4: ...urces before servicing the equipment To avoid explosion do not operate this equipment in an explosive atmosphere Qualified service personnel should perform safety checks after any service If this equi...
Страница 5: ...ply A substitute line cord may not be rated for high current 1 5 LAMP HANDLING Read all information and warnings provided with lamp Never touch any lamp or the reflector s inner surface with bare fing...
Страница 6: ...50 W 60000 Housing with 60025 Interface Kit 60013 66901 66902 66904 66905 66912 67001 67005 66158 6251NS Xe 75 W 60000 Housing with 60025 Interface Kit 60014 66901 66902 66904 66905 66912 67001 67005...
Страница 7: ...mp Housings Q Housing Socket Adapter Research Lamp Housings Socket Adapter OPS A500 6283NS Hg 200W n a 66901 66902 66904 66905 66912 67001 67005 66144 6289 HgXe 200W n a 66901 66902 66904 66905 66912...
Страница 8: ...es to carry or locate the power supply WARNING Do not attempt to operate this equipment if there is evidence of shipping damage or there is suspicion that the equipment will not operate correctly Dama...
Страница 9: ...nd monitoring various features of the power supply a Lamp Operating Mode b Manual Timed Shutter Control Display Features c Saving loading particular setups C SHUTTER This button is for manual control...
Страница 10: ...e 2 OPS A Power Supply Rear Panel Connections A AC IN Before powering up the system for the first time it is suggested to have a qualified electrician verify the wall socket to be used with the power...
Страница 11: ...this manual D OUTPUT 1 The interconnection cables between the lamp housing and power supply are noted in the table below A safety interlock feature does not allow the lamp to start if the cable or ca...
Страница 12: ...p will begin emitting light Do not press the Lamp On button until the output flange is directed in such a way that people animals and equipment will not be harmed by the light If there are any questio...
Страница 13: ...er supply and related components lamp lamp housing cable s are prepared for lamp ignition or displays Interlock Open indicating a problem with the system setup Similar error messages such as Cooler No...
Страница 14: ...ferenced need to be re examined for secure connection s 4 INTERLOCK CABLES CONNECTIONS TO LAMP HOUSINGS A lamp interconnection cable must be purchased for use with an arc lamp housing based on the typ...
Страница 15: ...please contact Oriel Instruments Oriel Instruments can only guarantee that the OPS Power Supply will meet performance specifications and be operated safely if lamp housing interconnection cables provi...
Страница 16: ...panel of the power supply Figure 5 The electrical connector on a 60025 DC Arc Lamp Interface Kit for use with an OPS A Model Power Supply 4 2 CONNECTION TO A RESEARCH LAMP HOUSING For connecting the O...
Страница 17: ...operation it is recommended that all connection cables be connected for loose connections and the door of the lamp housing be confirmed as completely closed and secured Figure 7 The Interlock Open and...
Страница 18: ...cular parameter can be changed will appear That parameter can now be changed by rotating the knob to the right of the vertical menu buttons Be aware that Pmax cannot be changed when the lamp is ignite...
Страница 19: ...e is set too low for the lamp to reach the desired Pset If this error message appears power down the lamp Then change Lamp Mode to Current Mode as described in the next section Increase the Imax param...
Страница 20: ...tal menu button under the Lamp Mode icon on the LCD display until the text under Lamp Mode reads Current as shown in the figure above 2 Upon reaching the Constant Power mode option the vertical menu f...
Страница 21: ...ermine the current setting by using Ohm s Law Amperes Power Voltage 4 Press CLEAR to clear the vertical menu from the screen and observe the desired operating parameter in real time while the lamp is...
Страница 22: ...Meter Resolution Current 0 01 A Safety Interlock Voltage 12 VDC GND Operating Mode Constant Current Power or Intensity Operating Temperature 10 45 C Max Relative Humidity 80 Max Weight lb kg 12 6 Max...
Страница 23: ...wport com Repair Service rma service newport com Customers outside of the United States must contact their regional representative for all sales technical support and service inquiries A list of world...
Страница 24: ...t for release without restriction First printing 2014 2014 by Newport Corporation Irvine CA All rights reserved No part of this manual may be reproduced or copied without the prior written approval of...