1.0

 

Getting Started 

The Model 8310CE closed loop Picomotor™ actuator has two cables—the motor cable 
terminated with a RJ-22 connector, and the encoder/limitswitch cable terminated in a 
high-density DB-15 connector. Because only the patented Picomotor drive waveform 
can be used to drive the Picomotor actuator, you must insert the RJ-22 connector into a 
Newport 

Picomotor controller & driver module (Model 8742 4-channel open loop, 

Model 8743-CL 2-channel closed loop), or single-axis Picomotor driver module (Model 
8703 TTL/Analog driver). With these recommended drivers you should be able to move 
the actuator through a hand terminal (Model 8758), or computer (refer to the driver 
manuals for specific motion-control command sets).

 

If you are using the Model 8743-CL closed loop Picomotor controller & driver module, 
connect the high-density DB-15 to the driver’s DB-15 port, and refer to the Model 
8743-CL manual for more detailed directions on interfacing with the Model 8310CE.

 

If you are using a third-party motion controller, refer to the cable pinout to interface 
with the controller. (Keep in mind that you will still need to use a Picomotor driver such 
as the Model 8742 Picomotor controller & driver module or the Model 8703 
TTL/Analog Picomotor driver module). The Model 8310CE is compatible with any 
third-party motion controller that can read TTL-level quadrature encoder signals. The 
limit sensors are openemitter outputs. When the actuator is centered, these outputs are 
pulled low through a transistor that is rated to 20 mA. When the actuator reaches its end 
of travel, one of the limit sensors will change to a floating voltage. By using a 10-k

Ω

 

pull-up resistor to 5 V, you can convert these sensor signals to TTL levels (See diagram 
in Cable Pinout).

 

 

NOTE

 

Do not open the motor cover or cut the motor cable. High voltages (up to 120 V, 
200 mA) are accessible with the cover removed or the cable cut. 

 

 

Содержание Closed Loop Picomotor 8310CE

Страница 1: ...Model 8310CE User Manual Closed Loop Picomotor Actuator...

Страница 2: ...arranty does not apply to defects resulting from modification or misuse of any product or part CAUTION Warranty does not apply to damages resulting from Incorrect usage Driven load greater than maximu...

Страница 3: ...d Closed Closed Closed Loop Picomotor Actuator Loop Picomotor Actuator Loop Picomotor Actuator Loop Picomotor Actuator User Manual User Manual User Manual User Manual 3 90092094 Rev A EDH0418En1010 11...

Страница 4: ...tes a potentially hazardous situation which can result in damage to product or equipment NOTE Note indicates additional information that must be considered by the user or operator European Union CE Ma...

Страница 5: ...personal injury CAUTION This motor is a Class A device In a residential environment this device can cause electromagnetic interference In this case suitable measures must be taken by the user WARNING...

Страница 6: ...ock the motor Do not use this motor if any foreign objects have entered the motor Switch off the motor power and then disconnect the electronics power supply Contact your Newport service facility for...

Страница 7: ...ntrol command sets If you are using the Model 8743 CL closed loop Picomotor controller driver module connect the high density DB 15 to the driver s DB 15 port and refer to the Model 8743 CL manual for...

Страница 8: ...s considerably smaller approximately 20 nm To achieve consistent nanometer level performance you need only keep a few precautions in mind Use a small amount of lubricant between the stainless steel ba...

Страница 9: ...2 kHz pulse rate 2 4 mm min 40 m s typical Closed loop Settling Time 100 ms with 8743 CL Controller Closed loop Steady State Error 0 counts with 8743 CL Controller Encoder Resolution 52 9 nm per encod...

Страница 10: ...p Picomotor Actuator User Manual User Manual User Manual User Manual 90092094 Rev A EDH0418En1010 11 19 10 5 0 Encoder Cable Pinout NOTE The Model 8310CE encoder outputs are differentially encoded on...

Страница 11: ..._____________________________________________________________________________________________________________ __________________________________________________________________________________________...

Страница 12: ...e mail service newport com Europe MICRO CONTROLE Spectra Physics S A S 9 rue du Bois Sauvage 91055 vry CEDEX France Sales Tel 33 0 1 60 91 68 68 e mail france newport com Technical Support e mail tech...

Отзывы: