newmotion Home Advanced Edition 7 Скачать руководство пользователя страница 17

INSTALLATIEHANDLEIDING – P17 

VERSION 0129NM02INT01 

INSTRUCTION MANUAL – P17  | 

P17

06A0RNM20ENG05

7.1 REGULAR USE

The first step is to connect your car to the charge point 
by plugging in the charge cable, the session will start 
automatically. Unplug the charge cable at the side of the 
car to stop the charge session.

When the car has delayed charging configured, the LED 
will remain green, until charging can start from car and 
charge point. 

When the charge point is configured to keep the cable 
lock permanently closed, the cable can only be removed 
after turning the power supply off.

Start charging? 

Plug in

Stop charging?

 Unplug at car

Full or waiting to charge
Plug in the charge cable in car
Charging
Error

Flashing green:

 starting procedure

7.2 ON/OFF PEAK CHARGING 

This charge point has the feature of On/Off peak 
charging. When this feature is installed, the owner of 
the charge point will be able to determine whether this 
feature may be enabled using the 3-way switch in the 
fuse box. An explanation of the position of the switches 
is given below:

Position A
Charging is always allowed, despite the On/Off peak 
signal of the smart meter.

Position B
Charging will only happen in Off peak. However, when 
the switch to Off peak occurs while the car is charging, 
the charge session will continue until the car is full 
without disturbing the charge session.

Position C
Charging will only happen in Off peak. When the switch 
to On peak occurs while the car is charging, the charge 
session will be delayed until another Off peak.

7. USER MANUAL & TROUBLESHOOTER

7.3 TROUBLESHOOTER

DO YOU SEE A RED LED LIGHT ON YOUR CHARGE 

POINT?

If so, it means your car won’t charge when plugged in. 
To fix this issue, turn 

off

 the Mechanical Circuit Breaker 

in the fuse box, wait 15 seconds, and turn it back 

on

.

IS YOUR CABLE STUCK IN THE CHARGE POINT? 

If you remove the charge cable from the car and the LED 
on the charge point turns out, the permanent cable lock 
feature of the charge point is enabled. If you do not want 
this feature, ask your installer to disable.
If you are unable to release the charge cable from your 
car, turn 

off

 the Mechanical Circuit Breaker in the fuse 

box and you will be able to release the cable. After 
releasing your charge cable, you can switch the power 
back 

on

 by turning the Mechanical Circuit Breaker 

on

DOES YOUR CAR CHARGE NOT CHARGE OR 

CHARGES VERY SLOWLY WHEN USING THE LOAD 

SHEDDING FUNCTIONALITY?

Please check whether the charging speed of your 
car varies. If the charging speed varies, there is little 
available capacity, as Load Shedding is an automatic 
function, the charge point takes into account the total 
electrical consumption of your household.

If charge speed does not increase when most of the 
devices in household are turned off, communication 
between your charge point and the Load Shedding 
module may be lost. Turn 

off

 the Mechanical Circuit 

Breaker, wait 15 seconds, and turn it back 

on

.

If the issue remains, contact your installer to check that 
the cable is working properly.

Содержание Home Advanced Edition 7

Страница 1: ...100 cm Home Basic Edition 7 Home Basic Edition 11 VERSION 06A0RNM20ENG05 2020 INSTRUCTION MANUAL EN...

Страница 2: ......

Страница 3: ...arth terminal for protection purposes The AC input clamps must be fitted with an uninterruptible earth for protection purposes Ensure that the connection cables are fitted with fuses and circuit break...

Страница 4: ...is not connected to a back office No online services or remote support are available for this charge point In case of an error or issue on site support is needed from a ZE Ready certified installer Y...

Страница 5: ...ule only for 11 kW model Cable mount clips For EV and ZE Ready installation Cable 5 x 1 5mm2 minimum for shunt and ON OFF peak accessories For EV Ready installation Shunt options ABB S2C A2 in combina...

Страница 6: ...protection class Certificates User interface Identification start charging Configuration Backoffice protocol Stand by consumption 06A _ _ _ _ _ _ 06B _ _ _ _ _ _ Home Basic Edition 7 single phase 32A...

Страница 7: ...lled outdoors with a road proximity less then 5 meters 3 2 TECHNICAL SPECIFICATIONS CONTINUED 3 PRODUCT OVERVIEW P1 DONGLE SPECIFICATIONS 11 KW MODEL ONLY Operating temperature range Operating humidit...

Страница 8: ...EIDING P8 VERSION 0129NM02INT01 INSTRUCTION MANUAL P8 P8 06A0RNM20ENG05 3 3 OVERVIEW OF PRODUCT 3 PRODUCT OVERVIEW Type 2S shutter EV Plug socket Cover lid Identification label with serial number LED...

Страница 9: ...2INT01 INSTRUCTION MANUAL P9 P9 06A0RNM20ENG05 3 PRODUCT OVERVIEW 3 4 1 OVERVIEW OF CONNECTIONS 7 4 KW VERSION Neutral wire connection Phase wire connection Earth wire connection Power cable Cable cla...

Страница 10: ...CTION MANUAL P10 P10 06A0RNM20ENG05 Tension relief data cable 3 PRODUCT OVERVIEW 3 4 2 OVERVIEW OF CONNECTIONS 11 KW VERSION Phase 1 Phase 2 Phase 3 Power cable inlet Cable clamp Earth Earthing pole N...

Страница 11: ...cable 11 kW model CAT5 6 UTP cable 5 wires 1 5mm2 minimum accessories cable inlet Shunt connection L1 N from accessories cable ON OFF Peak connection L2 L3 from accessories cable 11 kW model RJ12 P1 p...

Страница 12: ...charge point can also be connected to 1 phase In this case the charge point can only charge on 1 phase The electrician must select a suitable MCB with C characteristic to match the amperage setting of...

Страница 13: ...Overview of Connections 7 4 kW Version or 3 4 2 Overview of Connections 11 kW Version section 5 4A LOAD SHEDDING CT FOR 7 4 KW MODEL The Current Transformer for Load Shedding included in box must be c...

Страница 14: ...LED will indicate whether the connection is correct If the P1 LED does not show any signal please check if the RJ12 connectors are properly connected using a network cable tester If the led of the P1...

Страница 15: ...5 Volts and should be connected to the 5V pin left on the module The middle pin is not used Step 9 Plug the power adapter into a power outlet The Power LED C must light up Step 10 Consult with the cu...

Страница 16: ...ABLE LOCK If the installation requires a tethered cable solution the permanent cable lock feature can be enabled Move the righter dip switch underneath the rotary switches downwards to enable the perm...

Страница 17: ...ak When the switch to On peak occurs while the car is charging the charge session will be delayed until another Off peak 7 USER MANUAL TROUBLESHOOTER 7 3 TROUBLESHOOTER DO YOU SEE A RED LED LIGHT ON Y...

Страница 18: ......

Отзывы: