Connect the communicating device to the J305 Ethernet port inside the energy manager.
2.
Open an internet browser such as Edge, Chrome, Firefox or similar on the device.
3.
Enter the Ethernet default IP address into the internet browser.
N
OTE
: the energy manager IP address can be located from the front panel LCD menu under:
Settings>Networking>Ethernet.
4.
The energy manager log in page appears.
5.
Enter the user name and password. See
7.1 Access Levels
.
7.3
USB Connection
Figure 17: 3U EM4x-01 Front Panel micro-USB
1.
Connect the communicating device to the micro-USB port on the front of the energy manager. See
Figure 17
.
A driver installation prompt appears.
2.
Double-click the appropriate USB driver (32bit or 64 bit).
3.
Follow the installation wizard instructions to install the driver.
4.
Open an internet browser such as Edge, Chrome, Firefox or similar.
5.
Enter the USB default IP address into the internet browser: 172.31.250.1
6.
The energy manager log in page appears.
6.
Enter the username and password. See
7.1 Access Levels
.
Note: USB connection to the energy manager is possible without AC, battery or other external power supply.
The EM4x operates drawing power through the USB port. However, USB supply does not power the IO Board.