Phone: 714-751-0488
Fax: 714-957-1621
E-Mail: [email protected]
www.newmarpower.com
P.O. Box 1306
Newport Beach,
California 92663
20
12 Volt Models
Switch
Output Voltage (VDC)
Position
Use For
@ Charge
@ Float
A
Equalization
CAUTION
15.2
13.2
B
Equalization
CAUTION
14.6
13.2
C
Flooded/AGM Charging
14.2
13.2
D
Gel-Cell Charging
13.8
13.2
24 Volt Model
Switch
Output Voltage (VDC)
Position
Use For
@ Charge
@ Float
A
Equalization
CAUTION
30.4
26.4
B
Equalization
CAUTION
29.2
26.4
C
Flooded/AGM Charging
28.4
26.4
D
Gel-Cell Charging
27.6
26.4
32 Volt Model
Switch
Output Voltage (VDC)
Position
Use For
@ Charge
@ Float
A
Equalization
CAUTION
40.7
35.2
B
Equalization
CAUTION
39.2
35.2
C
Flooded/AGM Charging
37.9
35.2
D
Gel-Cell Charging
36.8
35.2
Operating Temperature (all models):
-22° C to +40° C (0° F to 104°F)
Mechanical Features (all models):
!
Thermally controlled cooling fan
!
GFCI protected duplex outlets
!
Powder coated aluminum case with integral mounting flanges
!
Conformal coated printed circuit boards
Protection Features (all models):
!
Automatic low battery shutdown
!
Output circuit breakers
!
Auto high temperature shutdown/recovery
!
Short circuit protection
!
Overload protection
Compliance:
UL 458 Listed
Options
!
Remote control and indicator panel; provided with 25‘ of cable. Model: ICR-2
!
Battery Integrator for charging multiple output banks*. Models: BI-100, BI-24-100
*Not available for 32 volt systems; contact factory for alternate methods
!
Digital DC Energy monitor for precise indication of battery volts, amps, amp-hours used
and remaining. Includes programmable high/low voltage remote alarms. Model: DCE