POWER FAILURE

In case of prolonged power failure, remove the blower access door and air filters. The draft fan will be off, so if 

more combustion air is needed for the wood fire, open the slide plate damper in the firedoor. This damper must 

be closed when power is restored.

DO NOT CHARGE the firebox higher than half way up the liner as overheating may result.

FUEL

Seasoned  cord  wood  will  give  the  most  heat.  Your  furnace  will  burn  most  any  type  of  firewood.  Seasoned 

hardwood produces more heat, and will hold a fire longer, leaving a hotter coal bed than seasoned softwood. 

Coal should never be used in a heater designed for burning wood. Never use driftwood that has been in salt 

water. The salt content will cause corrosion that will destroy stainless steel lined chimneys, flue connectors and 

the firebox.

Hard wood cut to 19” maximum length, and split 4” to 10” cross section is recommended for best operating 

efficiency.

LOADING OF FUEL

Do not overfill the firebox above the firebrick. A burned-out heat chamber may result. Do not use artificial or wax 

logs. Build fire on the floor of the firebox. Do not use additional grates or andirons to support the fire as these may 

create excessive heat.

PREPARATION AND STORAGE OF FUEL

Solid fuel should be cut and split prior to the heating season and stored in a well, aired dry place. Do not store 

fuel within the room heater clearances or within the space required for fueling or ash removal. Fuel should be 

kept at least 5ft clear (1.5m) from the furnace. The space around the furnace should be kept free of litter and 

wood residue.

REFUELING

The loading door should be closed at all times except when refueling. Before opening the loading door, make 

sure  the  thermostat  is  turned  up  and  the  draft  fan  on.  Allow  the  fire  to  burn  rather  briskly  for  a  few  minutes. 

Then open the loading door slowly. By allowing the fire to increase for a short period, a high draft condition has 

eliminated smoke in the firebox and the temperature has been raised which prevents a back or down draft.

CAUTION:

 Do not operate furnace with the loading door open. Continuous operation with a door open will 

cause severe overheating and warping. This furnace is designed for Thermostatic operation.

CAUTION: Burn untreated firewood only. Wood containing preservative, metal foils, coal, plastic, garbage, 

sulfur or oil is environmentally hazardous and will damage the appliance.

Содержание WFA-85

Страница 1: ...WFA 85 WFA 85E All installations must be made in accordance with local and provincial or state codes which may differ from the manual FOR COMMERCIAL USE ONLY USA ONLY NOTICE READ THESE INSTRUCTIONS SA...

Страница 2: ...rect drive motor refer to the Motor Installation Guide A fan center is required to isolate motor leads and to control continuous low speed operation from the thermostat Select the motor heating speed...

Страница 3: ...mper with this furnace 3 Caution If this furnace is used as a replacement for an existing furnace observe the following a Make sure there is a minimum of 6 clearance above the warm air plenum as far a...

Страница 4: ...k drafts whether or not there is combustion present 5 Existing fuel fired equipment in the building such as fireplaces or other heating appliances smell and do not operate properly suffer smoke roll o...

Страница 5: ...of wood being burnt Slide plate B should be open when burning wood When the firebox gets full of ash within two inches of door level some morning before loading the firebox push or rake the coals to t...

Страница 6: ...red temperature It is very important to keep the secondary flames burning to maximize heat output and minimize air pollution so some experimentation will be necessary because each installation is diff...

Страница 7: ...box Do not use additional grates or andirons to support the fire as these may create excessive heat PREPARATION AND STORAGE OF FUEL Solid fuel should be cut and split prior to the heating season and s...

Страница 8: ...m the summer months or any other source will mix with the ash or creosote and cause corrosion of the heat exchanger Corrosion is not covered under warranty NOTE Establish a routine for the storage of...

Страница 9: ...clearances Do not use salt wood driftwood gathered from the seashore Return air ducts are to be metal not wooden TO PREVENT DAMAGE Do not set the flue draft above 05 W C as the fire could burn out of...

Страница 10: ...should hold brick lock up to correct height 4 Install brick by starting at front putting one 1 bottom brick in place then slide one 1 top brick in place Repeat this procedure going down both sides an...

Страница 11: ...at exchanger move the front towards the door opening and pull the tube out of the secondary box 7 Remove through the door opening 8 Repeat the previous steps for the other secondary tube 9 Reach in an...

Страница 12: ...102013 PRT SECONDARY AIR SLIDE PLATE SECONDARY AIR INLET FIREDOOR SLIDE PLATE DAMPER PRIMARY AIR INLET DRAFT CONTROL SLIDE PLATE FAN AND LIMIT CONTROL WIRING CONTROL CHANNEL EXHAUST GASES SMOKE PIPE A...

Страница 13: ...Blue Black wire is TEW 14 1 Yellow wire is TEW 18 7 Blower wire is SPT 3 From insert Blue wire to fan terminal White wire to N terminal Red line to terminal Without Insert White 120V supply to N term...

Страница 14: ...s used WHY THIS CONCERN ABOUT ALLOWING THE WOOD TO DRY Green or wet wood is undesirable for several reasons Green or wet wood tends to mildew and rot which causes a significant reduction in the therma...

Страница 15: ...eosote is to leave the air inlet moderately open after adding wood until the wood is mostly reduced to charcoal and then close the inlet as much as desired This will promote complete combustion during...

Страница 16: ...its air supply although both water and salt are sometimes suggested if a relatively airtight stove is the connected appliance This is easily done by closing the stove s air inlet dampers if all the st...

Страница 17: ...4 03 590 96 Yellow Birch 3000 26 200 000 709 2 496 44 531 90 567 36 Elm 2750 24 500 000 662 8 463 96 497 10 530 24 Soft Maple 2500 24 000 000 649 2 454 44 486 90 519 36 Tamarack 2500 24 000 000 649 2...

Страница 18: ...s furnace must be connected to a separate fused disconnect switch supplying power to the appliance The furnace must be suitably grounded 2 Install the BX cable containing three wires from the Electric...

Страница 19: ...31 18 Place electrical unit directly into supply air of furnace Screw adapter in place for WFA 70 Interlock wire into junction box or front channel CAUTION Only one source of electrical supply shall...

Страница 20: ...ectric thermostat to screw on 24V transformer Disconnect black wire on transformer from previous location Cut red between limit relay and connect black from transformer with red end For connection wit...

Страница 21: ...21 Notes...

Страница 22: ...ranty Brick Rack Top Frame 28160 1 F L Bracket Welded 610605 1 Baffle WAO D3090226 1 Firedoor Assembly 610649 1 Hinge Pin P626H 83485 4 Shovel Handle D3080161 1 Weld Scraper D4080112 1 Draft Control K...

Страница 23: ...void the warranty SA Face Plate D3160623 1 Sec Air Back Plate D4060275 1 Front Gasket D2080001 1 G12 Delhi Blower Fan D2040103 1 Weld Formed Frame D4060194 1 Sec Air Slide D4060276 1 Front Panel 61063...

Страница 24: ...D2020003 1 DRAFT FAN PACKAGE D4100105 1 PULLEY 3 1 4 X 1 2 VS MTR D2240001 1 Firedoor Spacer D2080003 1 Durolon Dovetail Gasket D2080002 1 Firedoor Liner D3160464 1 Firedoor Chute Weld D4060189 1 Inne...

Отзывы: