Technical data
Manual DMT-TFT.110
11
3.4
Wiring
Irreparable damage to the electronics!
Make sure that the panel is earthed
.
3.4.1 Standard wiring
Visual acknowledgement is only possible if button acknowledgement functions independently.
Example of button with decoupled acknowledgement
3.4.2 Wiring for individual buttons
With this wiring type, the buttons are connected to signal lines 0 to 7 (optionally with programmable
inputs) and GND.
GND (X4.10)
Signal 0 (X4.2)
0
Signal 1 (X4.3)
1
Signal 2 (X4.4)
2
Signal 3 (X4.5)
3
Signal 4 (X4.6)
4
Signal 5 (X4.7)
5
Signal 6 (X4.11)
6
Signal 7 (X4.12)
7
Prog. input (X4.8)
Optional
Prog. input (X4.9)
Optional
4.2
4.3
4.4
4.5
4.6
4.7
4.11
4.12
NO
0
4.8
4.9
Optional
C
NO
1
C
NO
2
C
NO
3
C
NO
4
C
NO
5
C
NO
6
C
NO
7
C
TFT 110
4.10
GND
prog. E
1
prog. E
2
Example of 1 x 8 (+2) wiring