15
Use of Programming Command
Besides the barcode programming method, the scanner can also be configured by serial commands (HEX) sent from the
host device.
All commands must be entered in uppercase letters
.
Command Syntax
Prefix StorageType Tag SubTag {Data} [,SubTag {Data}] [;
Tag SubTag {Data}] […]
Suffix
Prefix
: “~<SOH>0000” (HEX:
7E 01 30 30 30 30
), 6 characters.
StorageType
: “
@
” (HEX:
40
) or “#” (HEX:
23
), 1 character. “
@
” means permanent setting which will not be lost by removing
power from the scanner or rebooting it
; “#” means temporary setting which will be lost by removing power from the scanner
or rebooting it.
Tag
: A 3-character case-sensitive field that identifies the desired command group. For example, all USB HID-KBW
configuration settings are identified with a Tag of KBW.
SubTag
: A 3-character case-sensitive field that identifies the desired parameter within the tag group. For example, the
SubTag for the keyboard layout is CTY.
Data
: The value for a feature or parameter setting, identified by the Tag and SubTag.
Suffix:
“;<ETX>” (HEX:
3B
03
), 2 characters.
Multiple commands can be issued within one Prefix/Suffix sequence. For configuration commands, only the
Tag
,
SubTag
,
and
Data
fields must be repeated for each command in sequence. If an additional command is to be applied to the same
Tag, then the command is separated with a comma (,) and only the
SubTag
and
Data
fields of the additional commands
are issued. If the additional command requires a different
Tag
field, the command is separated from previous command by
a semicolon (;).
Query Commands
For query commands, the entry in the
Data
field in the syntax above is one of the following characters means:
* (HEX:
2A
) What is the scanner’s current value for the setting(s).
& (HEX:
26
) What is the factory default value for the setting(s).
^ (HEX:
5E
) What is the range of possible values for the setting(s).
Содержание NLS-HR42
Страница 1: ...NLS HR42 2D Handheld Barcode Scanner User Guide...
Страница 23: ...9 Dimensions Left View Front View...
Страница 24: ...10 Top View...
Страница 39: ...25 SCNMOD3 Continuous Mode SCNMOD7 Batch Mode SCNMOD5 Aiming Mode SCNMOD4 Pulse Mode SCNMOD1 Trigger Mode...
Страница 48: ...34...
Страница 65: ...51 KBWCTY27 UK KBWCTY28 Japan...
Страница 79: ...65 KBWPOR8 9ms KBWPOR9 10ms...
Страница 114: ...100 FEBSDT35 35ms FEBSDT40 40ms FEBSDT45 45ms FEBSDT50 50ms FEBSDT55 55ms FEBSDT60 60ms FEBSDT65 65ms...
Страница 115: ...101 FEBSDT70 70ms FEBSDT75 75ms...
Страница 116: ...102 Transmit Delay per 12 Characters FEBMEN0 Disable FEBMEN1 Enable...
Страница 118: ...104 FEBMDT6 800ms FEBMDT7 900ms...
Страница 168: ...154 Enable Disable PDF417 ECI Output PDFECI0 Enable PDF417 ECI Output PDFECI1 Disable PDF417 ECI Output...
Страница 184: ...170 DMCREC1 Enable Rectangular Barcode DMCREC0 Disable Rectangular Barcode...
Страница 186: ...172 Enable Disable Data Matrix ECI Output DMCECI1 Enable Data Matrix ECI Output DMCECI0 Disable Data Matrix ECI Output...
Страница 198: ...184 PNTCHK1 Do Not Transmit USPS Postnet Check Character PNTCHK2 Transmit USPS Postnet Check Character...
Страница 236: ...222 CID099 Modify USPS Planet Code ID CID100 Modify KIX Post Code ID CID101 Modify Australian Postal Code ID...
Страница 242: ...228 Appendix Digit Barcodes 0 9 DIGIT0 0 DIGIT1 1 DIGIT2 2 DIGIT3 3 DIGIT4 4 DIGIT5 5...
Страница 243: ...229 DIGIT6 6 DIGIT7 7 DIGIT8 8 DIGIT9 9...
Страница 244: ...230 A F DIGITA A DIGITB B DIGITC C DIGITD D DIGITE E DIGITF F...
Страница 254: ...240 Terminating Character Suffix Enabled CR 0x0D Max 2 characters...