Enter Setup
】
Scan Mode
Manual Mode
A trigger pull activates a decode session. The decode session continues until the barcode is decoded or
you release the trigger or decode session timeout expires.
**
【
Manual Mode
】
Decode Session Timeout
This parameter sets the maximum time decode session continues during a scan attempt. It is
programmable in 1ms increments from 0ms to 3,600,000ms. The default setting is 3,000ms.
【
Decode Session Timeout
】
Set the Decode Session Timeout to 1,500ms:
1. Scan the
Enter Setup
barcode.
2. Scan the
Decode Session Timeout
barcode.
3. Scan the numeric barcodes “1”, “5”, “0” and “0”. (See the
Digit Barcodes
in
Appendix
)
4. Scan the
Save
barcode. (See the
Save/Cancel Barcodes
in
Appendix
)
5. Scan the
Exit Setup
barcode.
**
【
Exit Setup
】