background image

host. 

 

Chapter 14, Batch Programming 

         

: Explains how to integrate a complex programming task into a single barcode. 

 

Appendix

 

         

: Provides factory defaults table and a bunch of frequently used 

programming barcodes.

 

 

 

Explanation of Symbols 

• 

This symbol indicates lists of required steps. 

 

    This symbol indicates notes of some parameters. 

 

 

Explanation of Icons 

 

This icon indicates auxiliary tools that help users to refer   

to the manual at ease. 

 

This icon indicates this information requires extra   

attention from the reader.

 

 

This icon indicates handy tips that can help you use or   

configure the scanner with ease.

 

 

This icon indicates practical examples that can help you 

to acquaint yourself with operations.

 

 

Содержание NLS-FM515 Series

Страница 1: ...Fixed Mount Barcode Scanner NLS FM515 Series...

Страница 2: ...tion or design at any time without notice The information contained herein is subject to change without prior notice The products depicted in this manual may include software copyrighted by Fujian New...

Страница 3: ...Revision History Version Description Date V1 0 0 Initial release June 29 2022...

Страница 4: ...on 5 Dimensions unit mm 5 Installation 6 Mounting 8 7 pin Hot tinned Wire 9 Length of Cable 9 ESD 10 Dust and Dirt 10 Ambient Environment 10 Thermal Considerations 11 Maintenance 11 Chapter 3 Optics 1...

Страница 5: ...gramming 22 Programming Barcode Programming Command Function 23 Use of Programming Barcodes 24 Default Settings 25 Factory Defaults 25 Custom Defaults 25 Query Product Information 26 Query Product Nam...

Страница 6: ...igger Duration 48 Debounce Duration 49 Switching Output Signal 50 Enable Disable Switching Output 50 Output High Low Level 51 Output Duration 51 Enable Level Output 52 Stop Level Output 53 Chapter 10...

Страница 7: ...Convert UPC E to UPC A 68 UPC A 69 Restore Factory Defaults 69 Enable Disable UPC A 69 Transmit Check Character 69 2 Digit Add On Code 70 5 Digit Add On Code 71 Add On Code Required 72 Transmit Pream...

Страница 8: ...8 88 Set Length Range for GS1 128 89 AIM 128 90 Restore Factory Defaults 90 Enable Disable AIM 128 90 Set Length Range for AIM 128 91 ISBT 128 92 Restore Factory Defaults 92 Enable Disable ISBT 128 92...

Страница 9: ...125 Terminating Character Suffix 127 Enable Disable Terminating Character Suffix 127 Set Terminating Character Suffix 127 Chapter 13 Programming Commands 129 Use of Programming Command 129 Query Comma...

Страница 10: ...Code ID Table V1 00 0 145 Symbology ID Number V1 00 0 146 ASCII Table 147 Unicode Key Maps 151...

Страница 11: ...s Chapter 3 Optics Provides parameters for optics and illumination Chapter 4 Electrical Specifications Includes the electrical characteristics for the scanner and timing sequences Chapter 5 External R...

Страница 12: ...icates lists of required steps This symbol indicates notes of some parameters Explanation of Icons This icon indicates auxiliary tools that help users to refer to the manual at ease This icon indicate...

Страница 13: ...s The NLS FM515 series includes NLS FM515 V lateral beam exit and NLS FM515 H front beam exit distinguished by the direction of the beam exit Note This guide provides general instructions for the inst...

Страница 14: ...4 FM515 Scanner FM515 H LED Scan Window Mounting Hole Label Mounting Hole Cable Figure 1 1 FM515 V LED Scan Window Mounting Hole Label Mounting Hole Cable Figure 1 2...

Страница 15: ...and physical and optical information Caution Do not touch the imaging lens when installing the scanner Be careful not to leave fingerprints on the lens Caution Do not touch the illumination LED durin...

Страница 16: ...e View Top View Figure 2 1 8 34mil 10mil 6 67mil 10mil 8m i l 6 67mil 10mil 8m i l 6 67mil 8 34mil 10mil 8 34mil 10mil 6 67m i l 8 34mil 10mil 6 67m i l NLS FM515 H Scanning Range Horizontal Distance...

Страница 17: ...67mil 10mil 8m i l 6 67mil 10mil 8m i l 6 67mil 8 34mil 10mil 8 34mil 10mil 6 67m i l 8 34mil 10mil 6 67m i l NLS FM515 V Scanning Range NLS FM515 H Scanning Range Horizontal Distance mm Vertical Dis...

Страница 18: ...8 Mounting The illustrations below show the mechanical mounting dimensions unit mm for the FM515 FM515 H Figure 2 3 FM515 V Figure 2 4...

Страница 19: ...5 with 7 pin hot tinned wire can be connected to the host 7 pin hot tinned wire can be used as RS 232 communication The figure below illustrates wire colors of the 7 pin hot tinned wire Figure 2 5 Len...

Страница 20: ...ercise care when handling the scanner outside its package Be sure grounding wrist straps and properly grounded work areas are used Dust and Dirt The FM515 must be sufficiently enclosed to prevent dust...

Страница 21: ...hen integrating the FM515 Reserve sufficient space for good air circulation in the design Avoid wrapping the FM515 with thermal insulation materials such as rubber Maintenance The scan window should b...

Страница 22: ...on can be programmed On or Off Customers can add the external illumination system if needed The spectral range should be within the visible light The illumination LEDs produce a bar shaped pattern to...

Страница 23: ...powered on and enters the standby state Green LED flashes 200ms It indicates a good read Red LED flashes 200ms It indicates device malfunction Window Size The window must not block the field of view...

Страница 24: ...ation Eye Safety The FM515 has no lasers It uses LEDs to produce illumination beam The LEDs are bright but testing has been done to demonstrate that the scanner is safe for its intended application un...

Страница 25: ...15 Depth of Field The tables below list the depth of view tested in the 0lx and 300lx natural light Table 3 2 Ambient light 0lux or 300lux natural light FM515 H 35 190mm FM515 V 25 180mm...

Страница 26: ...erformance of the scanner Do not resupply the power immediately after cutting it off 1 When designing the user should ensure that the input power of FM515 is fully decoupled It is recommended to place...

Страница 27: ...ecode session continues until a barcode is decoded or you release the trigger For the external switching input circuit please see the Switching Input Circuit section in Chapter 5 For more details plea...

Страница 28: ...RMS value of the current under the stable working state 2 PEAK indicates the peak current the device reaches I O Voltage Table 4 4 GND 0 V T 25 C Note The VOH of SW_OUT determined by the pull up volta...

Страница 29: ...the scanner Initialization will be completed within 1s if the scanner functions well after power on 2 The initialization completes and the scanner can receive serial commands from the host 3 Before p...

Страница 30: ...t interface The SW_OUT signal is from black wire of the 7 pin hot tinned wire Figure 5 1 Switching Input Circuit The circuit below is used to provide the scanner with a signal to trigger a scan and de...

Страница 31: ...f online device Configure device Update firmware of online device Load modify existing XML configuration file save current settings to an XML file Create print save programming barcodes to a PDF or Wo...

Страница 32: ...anning barcodes As a result errors are more likely to occur Command Programming The FM515 can also be configured by serial commands sent from the host device Users can design an application program to...

Страница 33: ...e Programming Command Function The figure above is an example that shows you the programming barcode and command for the Enter Setup function 1 The No Case Conversion barcode 2 The No Case Conversion...

Страница 34: ...the setup mode scan the Exit Setup barcode or a non programing barcode or reboot the scanner Exit Setup Enter Setup Programming barcode data i e the characters under programming barcode can be transmi...

Страница 35: ...evious configuration and want to avoid its impact Restore All Factory Defaults Custom Defaults Scanning the Restore All Custom Defaults barcode can reset all parameters to the custom defaults Scanning...

Страница 36: ...product information including product name firmware version decoder version hardware version serial number OEM serial number and manufacturing date will be sent to the host device Query Product Inform...

Страница 37: ...Enter Setup 27 Exit Setup Query Decoder Version Query Decoder Version Query Hardware Version Query Hardware Version Query Product Serial Number Query Product Serial Number...

Страница 38: ...Enter Setup Exit Setup 28 Query Manufacturing Date Query Manufacturing Date Query OEM Serial Number Query OEM Serial Number Query Data Formatter Version Query Data Formatter Version...

Страница 39: ...etup Chapter 8 Communication Interface Introduction Serial communication interface is usually used when connecting the scanner to a host device like PC POS You need to set communication parameters to...

Страница 40: ...an automatically adapt its communication configuration to the way it is connected to the host device Automatically enable USB serial communication when connected to the host device via USB serial port...

Страница 41: ...erface is usually used when connecting the scanner to a host device like PC POS However to ensure smooth communication and accuracy of data you need to set communication parameters including baud rate...

Страница 42: ...Enter Setup Exit Setup 32 Baud Rate Baud rate is the number of bits of data transmitted per second Set the baud rate to match the host requirements 115200 57600 38400 19200 14400 9600 4800...

Страница 43: ...host requirements Odd Parity If the data contains an odd number of 1 bits the parity bit value is set to 0 Even Parity If the data contains an even number of 1 bits the parity bit value is set to 0 N...

Страница 44: ...ata Bits 8 Data Bits Stop Bit The stop bit s at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the ser...

Страница 45: ...er To suspend resume barcode reading simply press the trigger Reread Timeout can avoid undesired rereading of same barcode in a given period of time Level Mode Continuous Mode Decode Session Timeout T...

Страница 46: ...0ms 1 Scan the Enter Setup barcode 2 Scan the Decode Session Timeout barcode 3 Scan the numeric barcodes 1 5 0 and 0 from the Digit Barcodes section in Appendix 4 Scan the Save barcode from the Save C...

Страница 47: ...barcode Enable Reread Timeout Disable Reread Timeout The following parameter sets the time interval between two successive reads on same barcode It is programmable in 1ms increments from 0ms to 3 600...

Страница 48: ...ner encounters the same barcode that was decoded in the last scan session before the reread timeout expires To enable this feature scan the Reread Timeout Reset On barcode This feature is only effecti...

Страница 49: ...Delay Disable Good Read Delay To set the good read delay scan the barcode below then set the delay from 1 to 3 600 000ms by scanning the digit barcode s then scanning the Save barcode from the Append...

Страница 50: ...o send a bad read message user programmable when a good read does not occur before trigger release or the decode session timeout expires or the scanner receives the Stop Scanning command For more info...

Страница 51: ...numeric barcodes 4 and 6 from the Digit Barcodes section in Appendix 4 Scan the Save barcode from the Save Cancel Barcodes section in Appendix 5 Scan the Exit Setup barcode Trigger Commands When Enabl...

Страница 52: ...d Set the Start Scanning command to T 1 Scan the Enter Setup barcode 2 Scan the Modify Start Scanning Command barcode 3 Scan the numeric barcodes 2 A 5 and 4 from the Digit Barcodes section in Appendi...

Страница 53: ...ommand to P 1 Scan the Enter Setup barcode 2 Scan the Modify Stop Scanning Command barcode 3 Scan the numeric barcodes 2 A 5 and 0 from the Digit Barcodes section in Appendix 4 Scan the Save barcode f...

Страница 54: ...provided to improve the lighting conditions during every image capture Normal Illumination LEDs are turned on during image capture Off Illumination LEDs are off all the time Normal Off Good Read LED T...

Страница 55: ...ments from 1ms to 2 500ms Short 20ms Medium 120ms Long 220ms Prolonged 320ms Custom 1 2 500ms Set the Good Read LED duration to 800ms 1 Scan the Enter Setup barcode 2 Scan the Custom barcode 3 Scan th...

Страница 56: ...This parameter sets decoding times that is required to correctly read the barcode The higher the security level the lower the decoding error rate but the slower the speed Security Level 1 Security Le...

Страница 57: ...enabled there are two ways to trigger a decode session with a trigger pull as below Negative Slope Positive Slope LED off and decode session ends LED on and decode session continues Debounce time Enab...

Страница 58: ...ded or you release the trigger When it is set to 0 the time is infinite This feature is only applicable to the Level mode Trigger Duration Set the Trigger Duration to 1000ms 1 Scan the Enter Setup bar...

Страница 59: ...ggers a decode session The default setting is 10ms Debounce Duration Set the Debounce Duration to 20ms 1 Scan the Enter Setup barcode 2 Scan the Debounce Duration barcode 3 Scan the numeric barcodes 2...

Страница 60: ...Output Signal After Switching Output is enabled there are two ways to output level after a successful or failed decode Output High Level Output Low Level Enable Disable Switching Output Enable Switch...

Страница 61: ...ion after a successful or failed decode Output Duration Set the Output Duration to 500ms 1 Scan the Enter Setup barcode 2 Scan the Output Duration barcode 3 Scan the numeric barcodes 5 0 and 0 from th...

Страница 62: ...h low level after a good read m 0 it indicates the scanner doesn t produce high low level after a good read n 1 it indicates the scanner produces high low level after a failed read n 0 it indicates th...

Страница 63: ...ends m 0 it indicates the scanner continues producing high or low level when another decode session ends n 1 it indicates the scanner stop producing high or low level when another decode session star...

Страница 64: ...ymbologies It is recommended to disable those that are rarely used to increase the efficiency of the scanner Global Settings Enable Disable All Symbologies If the Disable All Symbologies feature is en...

Страница 65: ...scanned data will be enclosed in parentheses in the output message Do Not Surround GS1 AI s with Parentheses Surround GS1 AI s with Parentheses If Surround GS1 AI s with Parentheses is selected the ba...

Страница 66: ...ults Restore the Factory Defaults of Code 128 Enable Disable Code 128 Enable Code 128 Disable Code 128 If the scanner fails to identify Code 128 barcodes you may first try this solution by scanning th...

Страница 67: ...m length If minimum length is same as maximum length only Code 128 barcodes with that length are to be decoded Set the scanner to decode Code 128 barcodes containing between 8 and12 characters 1 Scan...

Страница 68: ...the scanner fails to identify EAN 8 barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable EAN 8 barcode Transmit Check Character EAN 8 is 8 digits in length with...

Страница 69: ...t circled by red dotted line is a two digit add on code Disable 2 Digit Add On Code Enable 2 Digit Add On Code Disable 2 Digit Add On Code The scanner decodes EAN 8 and ignores the add on code when pr...

Страница 70: ...t circled by red dotted line is a five digit add on code Disable 5 Digit Add On Code Enable 5 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes EAN 8 and ignores the add on code when p...

Страница 71: ...On Code Required Convert EAN 8 to EAN 13 Convert EAN 8 to EAN 13 Convert EAN 8 decoded data to EAN 13 format before transmission After conversion the data follows EAN 13 format and is affected by EAN...

Страница 72: ...Defaults Restore the Factory Defaults of EAN 13 Enable Disable EAN 13 Enable EAN 13 Disable EAN 13 If the scanner fails to identify EAN 13 barcodes you may first try this solution by scanning the Ent...

Страница 73: ...dotted line is an EAN 13 barcode while the part circled by red dotted line is a two digit add on code Disable 2 Digit Add On Code Enable 2 Digit Add On Code Disable 2 Digit Add On Code The scanner de...

Страница 74: ...Add On Code Disable 5 Digit Add On Code The scanner decodes EAN 13 and ignores the add on code when presented with an EAN 13 plus 5 digit add on barcode It can also decode EAN 13 barcodes without 5 d...

Страница 75: ...ory Defaults Restore the Factory Defaults of UPC E Enable Disable UPC E Enable UPC E Disable UPC E If the scanner fails to identify UPC E barcodes you may first try this solution by scanning the Enter...

Страница 76: ...new one In the example below the part surrounded by blue dotted line is a UPC E barcode while the part circled by red dotted line is a two digit add on code Disable 2 Digit Add On Code Enable 2 Digit...

Страница 77: ...git Add On Code Disable 5 Digit Add On Code The scanner decodes UPC E and ignores the add on code when presented with a UPC E plus 5 digit add on barcode It can also decode UPC E barcodes without 5 di...

Страница 78: ...ountry code 0 for USA or transmit no preamble System Character No Preamble System Character Country Code Convert UPC E to UPC A Convert UPC E to UPC A Convert UPC E zero suppressed decoded data to UPC...

Страница 79: ...he scanner fails to identify UPC A barcodes you may first try this solution by scanning the Enter Setup barcode and then Enable UPC A barcode Transmit Check Character UPC A is 13 digits in length with...

Страница 80: ...circled by red dotted line is a two digit add on code Disable 2 Digit Add On Code Enable 2 Digit Add On Code Disable 2 Digit Add On Code The scanner decodes UPC A and ignores the add on code when pre...

Страница 81: ...circled by red dotted line is a five digit add on code Disable 5 Digit Add On Code Enable 5 Digit Add On Code Disable 5 Digit Add On Code The scanner decodes UPC A and ignores the add on code when pr...

Страница 82: ...On Code Required Transmit Preamble Character Preamble characters Country Code and System Character can be transmitted as part of a UPC A barcode Select one of the following options for transmitting U...

Страница 83: ...Defaults of Interleaved 2 of 5 Enable Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 If the scanner fails to identify Interleaved 2 of 5 barcodes you may first try thi...

Страница 84: ...aximum length If minimum length is same as maximum length only Interleaved 2 of 5 barcodes with that length are to be decoded Set the scanner to decode Interleaved 2 of 5 barcodes containing between 8...

Страница 85: ...ith the check character algorithm Barcodes passing the check will be transmitted whereas those failing it will not be transmitted Since Interleaved 2 of 5 must always have an even number of digits a z...

Страница 86: ...efaults Restore the Factory Defaults of Code 39 Enable Disable Code 39 Enable Code 39 Disable Code 39 If the scanner fails to identify Code 39 barcodes you may first try this solution by scanning the...

Страница 87: ...length If minimum length is same as maximum length only Code 39 barcodes with that length are to be decoded Set the scanner to decode Code 39 barcodes containing between 8 and 12 characters 1 Scan th...

Страница 88: ...Verification The scanner checks the integrity of all Code 39 barcodes to verify that the data complies with the check character algorithm Barcodes passing the check will be transmitted whereas those...

Страница 89: ...or not to transmit the start stop characters by scanning the appropriate barcode below Do Not Transmit Start Stop Character Transmit Start Stop Character Enable Disable Code 39 Full ASCII The scanner...

Страница 90: ...e or disable Code 32 Code 39 must be enabled and Code 39 check character verification must be disabled for this parameter to function Disable Code 32 Enable Code 32 Code 32 Prefix Scan the appropriate...

Страница 91: ...nabled for this parameter to function Do Not Transmit Code 32 Start Stop Character Transmit Code 32 Start Stop Character Transmit Code 32 Check Character Code 32 must be enabled for this parameter to...

Страница 92: ...efaults Restore the Factory Defaults of Codabar Enable Disable Codabar Enable Codabar Disable Codabar If the scanner fails to identify Codabar barcodes you may first try this solution by scanning the...

Страница 93: ...length If minimum length is same as maximum length only Codabar barcodes with that length are to be decoded Set the scanner to decode Codabar barcodes containing between 8 and 12 characters 1 Scan th...

Страница 94: ...r Verification The scanner checks the integrity of all Codabar barcodes to verify that the data complies with the check character algorithm Barcodes passing the check will be transmitted whereas those...

Страница 95: ...r not to transmit the start stop characters by scanning the appropriate barcode below Do Not Transmit Start Stop Character Transmit Start Stop Character ABCD ABCD as the Start Stop Character ABCD TN E...

Страница 96: ...efaults Restore the Factory Defaults of Code 93 Enable Disable Code 93 Enable Code 93 Disable Code 93 If the scanner fails to identify Code 93 barcodes you may first try this solution by scanning the...

Страница 97: ...length If minimum length is same as maximum length only Code 93 barcodes with that length are to be decoded Set the scanner to decode Code 93 barcodes containing between 8 and 12 characters 1 Scan th...

Страница 98: ...tory Defaults Restore the Factory Defaults of GS1 128 Enable Disable GS1 128 Enable GS1 128 Disable GS1 128 If the scanner fails to identify GS1 128 barcodes you may first try this solution by scannin...

Страница 99: ...length If minimum length is same as maximum length only GS1 128 barcodes with that length are to be decoded Set the scanner to decode GS1 128 barcodes containing between 8 and 12 characters 1 Scan th...

Страница 100: ...efaults Restore the Factory Defaults of AIM 128 Enable Disable AIM 128 Enable AIM 128 Disable AIM 128 If the scanner fails to identify AIM 128 barcodes you may first try this solution by scanning the...

Страница 101: ...length If minimum length is same as maximum length only AIM 128 barcodes with that length are to be decoded Set the scanner to decode AIM 128 barcodes containing between 8 and 12 characters 1 Scan th...

Страница 102: ...ults Restore the Factory Defaults of ISBT 128 Enable Disable ISBT 128 Enable ISBT 128 Disable ISBT 128 If the scanner fails to identify ISBT 128 barcodes you may first try this solution by scanning th...

Страница 103: ...ish to clear all formats and return to the factory defaults scan the Default Data Format code below Default Data Format Add a Data Format Data format is used to edit barcode data When you create a dat...

Страница 104: ...ion in Appendix and find the ID number of the symbology to which you want to apply the data format Scan three numeric barcodes for the symbology ID number If you wish to create a data format for all s...

Страница 105: ...002 Only Code 128 applicable 7 Scan the barcodes 0010 Only a length of 10 characters applicable 8 Scan the alphanumeric barcodes F141 Send all characters followed by A HEX 41 9 Scan the Save barcode...

Страница 106: ...bology to which you want to apply the data format 3 characters 999 indicates all symbologies Data length The length of data that will be acceptable for this symbology 4 characters 9999 indicates all l...

Страница 107: ...ngly and gets outputted without prefixes and suffixes even if prefix and suffix are enabled Enable Data Formatter Not Required Keep Prefix Suffix Scanned data that meets your data format requirements...

Страница 108: ...Formatter Required Drop Prefix Suffix Enable Data Formatter Not Required Keep Prefix Suffix Enable Data Formatter Not Required Drop Prefix Suffix Data Format Selection After enabling the Data Formatte...

Страница 109: ...Enter Setup 99 Exit Setup Format_0 Format_1 Format_2 Format_3...

Страница 110: ...e you may have set your scanner to use the data format you saved as Format_3 You can switch to Format_1 for a single trigger pull by scanning the Single Scan Format_1 barcode below The next barcode th...

Страница 111: ...the Save barcode Delete all data formats Scan the Clear All barcode Clear All Clear One Query Data Formats You may scan the appropriate barcode below to get the information of data format s created b...

Страница 112: ...essage starting from current cursor position followed by an insert character F2 Send a number of characters Syntax F2nnxx nn The numeric value 00 99 for the number of characters xx The insert characte...

Страница 113: ...return Command string F3440D F3 is the Send all characters up to a particular character command 44 is the hex value for a D 0D is the hex value for a CR The data is output as 1234567890ABC CR E9 Send...

Страница 114: ...end to ignore F4 is the Insert a character multiple times command 09 is the hex value for a horizontal tab 02 is the number of time the tab character is sent The data is output as 1234567890AB tab tab...

Страница 115: ...ce 01 is the number of time the space character is sent B4 is the Insert barcode length command F4 is the Insert a character multiple times command 20 is the hex value for a space 01 is the number of...

Страница 116: ...cursor F1 is the Send all characters command 0D is the hex value for a CR The data is output as 4567890ABCDEFGHIJ CR F6 Move the cursor backward a number of characters Syntax F6nn nn The numeric valu...

Страница 117: ...Search for the letter D in barcodes and send all the data that follows including the D Using the barcode above Command string F844F10D F8 is the Search forward for a character command 44 is the hex v...

Страница 118: ...data that follows including FGH Using the barcode above Command string B00003464748F10D B0 is the Search forward for a string command 0003 is the string length 3 characters 46 is the hex value for F...

Страница 119: ...ll the data that follows E6 searches forward for the first character that is not zero then sends all the data after followed by a carriage return Using the barcode above Command string E630F10D E6 is...

Страница 120: ...You may want to remove the spaces before sending the data Using the barcode above Command string FB0120F10D FB is the Suppress characters command 01 is the number of the characters to be suppressed 20...

Страница 121: ...ll replace the zeros in the barcode above with carriage returns Command string E402300DF10D E4 is the Replace characters command 02 is the total count of characters to be replaced plus the replacement...

Страница 122: ...rrent cursor position search forward for the occurrence of SS1 string of length NFM515 and replace the string with SS2 string of length NN2 in the output message until every SS1 stringis replaced or t...

Страница 123: ...23 s in barcode data If the barcode has a string of characters that the host application wants removed you can use the BA command to replace the string with NUL In this example you will remove the fir...

Страница 124: ...character Send the first 5 characters in a barcode wait for 1s then send the rest of the barcode data Command string F20500EF0200E900 F2 is the Send a number of characters command 05 is the number of...

Страница 125: ...Left 01 Shift Right 02 Alt Left 04 Alt Right 08 Control Left 10 Control Right 20 For example B501001F inserts an a on a U S style keyboard B5 the command 01 number of keys pressed without the key modi...

Страница 126: ...ns they do not and should not have all information we need such as barcode type data acquisition time and delimiter in order to keep the barcodes short and flexible Preffix and suffix are how to fulfi...

Страница 127: ...barcode data with no prefix suffix Enable All Prefixes Suffixes Allow to append Code ID prefix AIM ID prefix custom prefix suffix and terminating character to the barcode data before the transmission...

Страница 128: ...x scan the Set Custom Prefix barcode then the numeric barcodes corresponding to the hexadecimal value of a desired prefix then the Save barcode Note A custom prefix cannot exceed 10 characters Set Cus...

Страница 129: ...ers ID defines symbology identifier For the details see the AIM ID Table section in Appendix If AIM ID prefix is enabled the scanner will add the symbology identifier before the scanned data after dec...

Страница 130: ...type Unlike AIM ID Code ID is user programmable Code ID can only consist of one or two English letters Disable Code ID Prefix Enable Code ID Prefix Restore All Default Code IDs For the information of...

Страница 131: ...nter Setup barcode 2 Scan the Modify PDF417 Code ID barcode 3 Scan the numeric barcodes 7 and 0 from the Digit Barcodes section in Appendix 4 Scan the Save barcode from the Save Cancel Barcodes sectio...

Страница 132: ...r Setup Exit Setup 122 1D symbologies Modify Code 128 Code ID Modify GS1 128 Code ID Modify EAN 8 Code ID Modify EAN 13 Code ID Modify UPC E Code ID Modify UPC A Code ID Modify Interleaved 2 of 5 Code...

Страница 133: ...Enter Setup 123 Exit Setup Modify Code 39 Code ID Modify Codabar Code ID Modify Code 93 Code ID...

Страница 134: ...x scan the Set Custom Suffix barcode then the numeric barcodes corresponding to the hexadecimal value of a desired suffix then the Save barcode Note A custom suffix cannot exceed 10 characters Set Cus...

Страница 135: ...rcode data length is expressed in 2 bytes ranging from 0x0000 0 to 0xFFFF 65535 AL_TYPE 0x36 DATA Raw barcode data LRC Check digit LRC calculation algorithm computation sequence 0xFF LEN AL_TYPE DATA...

Страница 136: ...Enter Setup Exit Setup 126 Disable Data Packing Enable Data Packing Format 1 Enable Data Packing Format 2...

Страница 137: ...rminating Character Suffix Enable Terminating Character Suffix Set Terminating Character Suffix To set a terminating character suffix scan the Set Terminating Character Suffix barcode then the numeric...

Страница 138: ...rcode 2 Scan the Set Terminating Character Suffix barcode 3 Scan the numeric barcodes 0 and A from the Digit Barcodes section in Appendix 4 Scan the Save barcode from the Save Cancel Barcodes section...

Страница 139: ...query all the current settings about Code 11 you should enter 7E 01 30 30 30 30 40 43 31 31 2A 3B 03 i e SOH 0000 C11 ETX Command Syntax Prefix StorageType Tag SubTag Data SubTag Data Tag SubTag Data...

Страница 140: ...ds with one of the following three responses ACK HEX 06 Indicates a good command which has been processed NAK HEX 15 Indicates a good configuration command with its Data field entry out of the allowab...

Страница 141: ...tup Enter 7E 01 30 30 30 30 40 43 31 31 4D 49 4E 2A 2C 4D 41 58 2A 3B 03 SOH 0000 C11MIN MAX ETX Response 02 01 30 30 30 30 40 43 31 31 4D 49 4E 31 32 06 2C 4D 41 58 32 32 06 3B 03 STX SOH 0000 C11MIF...

Страница 142: ...for the setting LEDONS Returning LEDONS 2C10 10000D ACK indicates the range for the length of time the LED stays lit is 10 10000ms Example Turn on the Good Read LED for 1 000ms Enter SOH 0000 LEDONS2C...

Страница 143: ...a semicolon Note that there is no space between a command and its terminator semicolon 3 Use the barcode generator software to generate a 2D batch barcode Example Create a batch barcode for Illuminati...

Страница 144: ...information refer to the Use of Programming Command section in Chapter 3 Create a Batch Barcode Batch barcodes can be produced in the format of PDF417 QR Code or Data Matrix Example Create a batch ba...

Страница 145: ...Enter Setup 135 Exit Setup Use Batch Barcode To put a batch barcode into use scan the following barcodes Use the example above Enter Setup Enable Batch Barcode Batch Barcode Exit Setup...

Страница 146: ...136 Appendix Digit Barcodes 0 9 0 1 2 3 4 5...

Страница 147: ...137 6 7 8 9...

Страница 148: ...138 A F A B C D E F...

Страница 149: ...it barcode and then the correct digit or scan the Delete All Digits barcode and then the digits you want For instance after reading the Maximum Length barcode and numeric barcodes 1 2 and 3 you scan D...

Страница 150: ...s Trigger Commands Disabled Start Scanning Command SOH T EOT Stop Scanning Command SOH P EOT Illumination Normal Good Read LED On Good Read LED Duration 20ms Security Level 1 Enable Disable Switching...

Страница 151: ...Add On Code Not Required Convert EAN 8 to EAN 13 Disabled EAN 13 EAN 13 Enabled Check Character Transmit 2 Digit Add On Code Disabled 5 Digit Add On Code Disabled Add On Code Not Required UPC E UPC E...

Страница 152: ...er Do not transmit Code 39 Full ASCII Disabled Code 32 Pharmaceutical PARAF Disabled Code 32 Prefix Disabled Code 32 Start Stop Character Do not transmit Code 32 Check Character Do not transmit Codaba...

Страница 153: ...uffix All Prefixes Suffixes Disabled Prefix Sequence Code ID Custom AIM ID Custom Prefix Enabled AIM ID Prefix Disabled Code ID Prefix Disabled Custom Suffix Disabled Data Packing Disable Data Packing...

Страница 154: ...Possible AIM ID Modifiers m Code 128 C0 GS1 128 UCC EAN 128 C1 EAN 8 E4 EAN 13 E0 EAN 13 with Addon E3 UPC E E0 UPC E with Addon E3 UPC A E0 UPC A with Addon E3 Interleaved 2 of 5 Im 0 1 3 Code 39 Am...

Страница 155: ...145 Code ID Table V1 00 0 Symbology Code ID Code 128 j GS1 128 UCC EAN 128 j EAN 8 d EAN 13 d UPC E c UPC A c Interleaved 2 of 5 e Code 39 b Codabar a Code 93 i...

Страница 156: ...146 Symbology ID Number V1 00 0 Symbology ID Number Code 128 002 GS1 128 UCC EAN 128 003 EAN 8 004 EAN 13 005 UPC E 006 UPC A 007 Interleaved 2 of 5 008 Code 39 013 Codabar 015 Code 93 017...

Страница 157: ...b 11 VT Vertical Tab 0c 12 FF Form Feed 0d 13 CR Carriage Return 0e 14 SO Shift Out 0f 15 SI Shift In 10 16 DLE Data Link Escape 11 17 DC1 XON Device Control 1 12 18 DC2 Device Control 2 13 19 DC3 XOF...

Страница 158: ...llar Sign 25 37 Percent 26 38 Ampersand 27 39 Single Quote 28 40 Left Opening Parenthesis 29 41 Right Closing Parenthesis 2a 42 Asterisk 2b 43 Plus 2c 44 Comma 2d 45 Minus Dash 2e 46 Dot 2f 47 Forward...

Страница 159: ...5 A 42 66 B 43 67 C 44 68 D 45 69 E 46 70 F 47 71 G 48 72 H 49 73 I 4a 74 J 4b 75 K 4c 76 L 4d 77 M 4e 78 N 4f 79 O 50 80 P 51 81 Q 52 82 R 53 83 S 54 84 T 55 85 U 56 86 V 57 87 W 58 88 X 59 89 Y 5a 9...

Страница 160: ...0 d 65 101 e 66 102 f 67 103 g 68 104 h 69 105 i 6a 106 j 6b 107 k 6c 108 l 6d 109 m 6e 110 n 6f 111 o 70 112 p 71 113 q 72 114 r 73 115 s 74 116 t 75 117 u 76 118 v 77 119 w 78 120 x 79 121 y 7a 122...

Страница 161: ...151 Unicode Key Maps 104 Key U S Style Keyboard 105 Key European Style Keyboard...

Страница 162: ......

Отзывы: