Filtering Flow Rate – This is the flow rate of incoming water and is used to calculate the volume of water that has been filtered.
The flow rates may be turned off or set for .25, .50, .75 or 1.00 gallon per minute (gpm) flow rates. The PDS valve on the rear
of the unit should be calibrated to match the recommended flow rate of .25 gpm to properly display the brew volume in the
quality check mode and to deliver the programmed brew volume.
Filter Capacity – The filtering capacity in gallons of the filter installed (optional) on the brewer may be selected here. Capacity
may be turned off or set for one of the following available values; 0, 500, 1500, 2000 or 2500 gallons.
Number of Brews – The number of brew cycles started may be tracked with this feature. The accumulated number of cycles
may be reset by using the brew buttons to display “Clr” when in the program mode and then depressing quality button. The
Quality check feature will also display the number of brews for both brew selections. The display is limited to 999 however the
control tracks up to 4000 brews internally. For each 1000 brew cycles completed a decimal point on the display is also
illuminated. Thus if 2 decimal points and 500 are displayed for TEA 1/2, there have been 2500 brew cycles since the counter
was last reset.
Auto Warmer Shutoff – For warmer equipped units the control may be programmed to shut off the warmers after a
programmed period of time. The time interval may be set for any period of time up to 4hours and 15 minutes or the feature
may be turned off so that warmers operate manually.
Power Mode - allows you to automatically save energy when the brewer is not in use for a length of time specified under power
shutdown time. Available modes are normal, power save (standby) and power down. The modes are described below.
=
Normal - In this mode the tank temperature will be maintained at the preset temperature at all times.
=
Power Save (Standby) - In this mode the tank temperature will be maintained at approximately 170
degrees when the set time has been reached.
=
Power Down - In this mode the tank heater element will be disabled when the set time has been reached.
By depressing the brew start switch or if the brewer looses power the timer is reinitialized and the set time frame starts over.
In standby and power down modes the auto arm feature, if enabled, will bring the tank up to the preset temperature before
brewing when the brew switch is depressed.
Power Shutdown Time – This feature is used to set a specified length of time ranging from 30 to 240 minutes before the
standby or power down modes will take effect.
CONTROL PANEL LAYOUT
TEA Brewer Control Panel – Warmer Model
Содержание AKPA-3 DB-T HW
Страница 2: ...2 Issued August 2013...
Страница 3: ...H 3 AKPA DB Combin ot Water T T 3 HW nation ea Brewer Issued August 2013...
Страница 5: ...5 Issued August 2013...
Страница 13: ...13 Issued August 2013 TEA BREWER FUNCTION WIRING DIAGRAM...
Страница 15: ...11A 13A 15 12A Issued August 2013...
Страница 17: ...17 Issued August 2013...
Страница 20: ...20 Issued August 2013...
Страница 23: ...A 17 17 20 23 19 Issued Aug 16 17 18 ust 2013 8...
Страница 24: ...24 Issued August 2013...