PROGRAMMING
SEQUENCE OF PROGRAMMING STEPS FOR THE DIGI-BREW CONTROLLER
∗
Depress and hold QUALITY button until display lights up (Approx. 10 seconds).
∗
You are now in the Program Mode. Functions to be programmed appear in the order in which they are shown in the following
table.
∗
Use the QUALITY button to cycle through the functions to find the one you wish to change.
∗
Use the TEA1/2 button to lower the displayed value and the TEA 1 button to raise the value. Press QUALITY
button to store the changed value and advance to next function.
∗
If the Brewer detects no activity for approx. 60 seconds it will exit the Program Mode, except as noted below
.
CODE
FUNCTION TO SET
SET VALUE OPTIONS
TEA BREWER
1A Brew
1
volume
(Left Button) OFF,
30 – 255 ounces
30 ounces
1b
Brew 2 volume (Right Button)
OFF, 30 – 255 ounces
60 ounces
2
Visa-brew time
OFF, 30 seconds – 2 ½ minutes
1:45
3
Water Temperature *1
170
°
F – 205
°
F 203
Degrees
F
4
Auto Arm
ON or OFF
On
5A
Pre-infusion 1 mode
ON or OFF
Off
5b
Pre-infusion 2 mode
ON or OFF
Off
6
Pulse brew mode
ON or OFF
On
6A
Pulse brew 1 time *2
1:15
6b
Pulse brew 2 time *3
3:15
7A
Audible alert mode
ON or OFF
On
7b
Audible alert no. of beeps
ON,OFF, 1 – 9
On(Continuous)
9A
Filtering flow rate
OFF, 0.25 – 1.00 gal. / min
.25 GPM
9b
Filter capacity *4
OFF, 0.50 – 2.50 gal. X 100 2000
gallons
10
Number of Brews
ON or OFF, Clr
N/A
11A
Auto Warmer Shutoff
ON or OFF
Off
11b
Time Interval before shutoff
0-4:15
N/A
12A
Power mode
Normal, Power Save, Power Down
Normal
12b
Power shutdown time *5
30 minutes – 4 hours
N/A
End None
*6
N/A
N/A
*1 Brewer will remain in this sequence indefinitely until CANCEL button is pressed.
*2 Hidden if pulse brew mode is OFF or brew 1 time is OFF.
*3 Hidden if pulse brew mode is OFF or brew 2 time is OFF.
*4 Hidden if filter flow rate is OFF.
*5 Hidden when power save mode is normal.
*6 Program mode will time out in 15 seconds at end of programming sequence.
ERROR MESSAGES
The following table explains the error messages which may be encountered on the brewer. The error messages may be cleared by going
into the program mode, using the brew buttons to display “Clr” and then pressing the cancel button.
ERRORMESSAGE DESCRIPTION
CAUSE
Er1
Fill run error
The fill solenoid has either run for more than six minutes on the initial tank fill or 3 minutes
in normal operation.
Er2
Heater run error
The tank heater has run for more than 30 consecutive minutes.
Er3
Shorted probe
Short in the thermistor circuit.
Er4
Open probe
Break in the thermistor circuit.
Ful
Filter limit reached
The selected filtering capacity of the filter has been reached
Содержание AKPA-3 DB-T HW
Страница 2: ...2 Issued August 2013...
Страница 3: ...H 3 AKPA DB Combin ot Water T T 3 HW nation ea Brewer Issued August 2013...
Страница 5: ...5 Issued August 2013...
Страница 13: ...13 Issued August 2013 TEA BREWER FUNCTION WIRING DIAGRAM...
Страница 15: ...11A 13A 15 12A Issued August 2013...
Страница 17: ...17 Issued August 2013...
Страница 20: ...20 Issued August 2013...
Страница 23: ...A 17 17 20 23 19 Issued Aug 16 17 18 ust 2013 8...
Страница 24: ...24 Issued August 2013...