background image

PAGE 8 

ACE SERIES BREWERS – REPLACEMENT PARTS LIST 

 

 

ELECTRICAL COMPONENTS 

 

TANK AND PLUMBING 

Part No 

Description 

Part No 

Description 

100010 

Warming plate ass'y 120 V, black 

102798  Tank ass'y, 120 V 1400 W 

100187 

Warming Element, 120 V 100 W 

102859  Tank ass'y, 120 V 1750 W 

102581 

Element main heating, 1100 W 120 V 

102746  Tank ass'y, 240 V 3500 W 

102580 

Element main heating, 1400 W 120 V 

104012  Tank lid ass'y 

100071 

Element main heating, 1750 W 120 V 

781181  Gasket, silicone tank 

102850 

Element main heating, 3500 W 240 V 

100024  Sprayhead, S/S 5 hole 

704227 

Main thermostat 

102820  Solenoid valve assembly with fittings 

111593 

Hi-limit Thermostat, manual reset 

102780  Solenoid valve, S-45 

100085 

Lighted rocker switch 120 V 

201158  Repair kit, solenoid valve 

201985 

Brew switch, black, rectangular 

790019  Gasket, flow control 

102775 

Dual lamp, brewing/ready indicating 120 V 

100290  .250 flow control washer 

102862 

Micro switch &bracket ass'y 

102770  Faucet w/red handle 

102841 

Micro switch only 

102268  Seat cup for faucet 

121723 

Control board ass'y with bracket, (non TS models)  110322  PDS low/flow assembly 

111725 

Control board ass'y with bracket, (TS models) 

102783  Sprayhead tube ass'y 

100500 

ON/OFF switch 

100025  Sprayhead gasket 

 

 

 

 

 

BREWBASKETS

 

 

MISC.

 

110985 

Brew basket assy, black plastic 

100078  Bumper foot with screw 

201954 

Filter pack brew basket 

108067  Probe ass'y, weldment 

102800 

Brew rail, LH 

201173  Sprayhead nut 

102799 

Brew rail, RH 

 

 

102370 

Brew basket, S/S small 

 

 

104010 

Brew rail, RH, S/S basket 

 

 

104011 

Brew rail, LH, S/S basket 

 

 

 

For additional replacement parts information refer to Ace Series replacement parts manual, P/N 108054. 

 

PDS Flow Control Supplemental Information 

 

The PDS flow control system is the result of many years of engineering effort to create a flow control valve that would be 

accurate over a wide range of water pressures as well as maintain its volume setting for many years within the harsh 

water environment that coffee brewing equipment must operate. 

 

The valve has been designed to allow for adaptation to all varieties of brewers, and is available in both a low flow (0.15 

GPM to 0.35 GPM) and high flow (0.56 to 1.25 GPM) model.  Both models have adjustable flow rates to any setting 

within the specified range.  The low flow models are identifiable by their red bonnet while the high flow models have a 

green bonnet.  See item 14 in figure below. 

 

Other features designed into the valve include an internal water strainer, a non-regulated water supply for connecting to 

independent faucets, an easy to adjust knob for setting the flow rate, double O-ring swivel fittings to eliminate leaks due 

to equipment being moved, and most importantly a porcelain sleeve and piston assembly that is self cleaning and 

cannot be affected by chemicals within the water supply.  The system has been designed to operate over a wide range 

of water pressures, from 10 PSI to 70 PSI for low flow models and from 40 PSI to 110 PSI for high flow models, with an 

accuracy of +/- 1%.  

 

The time setting of the brewer timer works in conjunction with the flow rate set on the PDS valve. This determines the 

volume of water being delivered for the brew cycle. If the valve is set at a rate of .25 GPM and the timer is set for 2 

minutes, the volume delivered wil be .25 x 2 or one half gallon (64 oz). Refer to table 1 for other flow rates, timer settings 

and volumes. Flow rate accuracy is critical as the timer setting will remain constant. 

 

 

 

 

 

 

Содержание Ace D

Страница 1: ...2 ACE LP 3 15 1 2 16 1 2 15 7 8 31 1710 1410 14 3 11 8 3810 17 2 ACE AP 0 8 1 2 17 11 16 22 1 4 29 1760 1410 14 7 11 8 3510 14 6 ACE D 0 8 1 2 17 11 16 26 1 4 32 1760 1410 14 7 11 8 3510 14 6 ACE TC 0 8 1 2 17 11 16 16 9 16 28 1760 1410 14 7 11 8 3510 14 6 ACE LD 0 8 1 2 17 11 16 20 1 8 28 1760 1410 14 7 11 8 3510 14 6 ACE TS 0 8 1 2 17 11 16 Varies 34 1760 1410 14 7 11 8 N A N A Newco Enterprises...

Страница 2: ...hen a brew cycle is initiated the control board verifies that the temperature in the tank is equal to the thermostat setting If the water temperature is not at proper temperature the brew is stored in memory and light will flash to indicate brewing When the temperature rises to the proper setting the brewer will automatically begin to brew If your brewer does not already have the auto arm feature ...

Страница 3: ...able to cancel brew cycle 4 Empty decanter and replace below the brewbasket Turn on the lower warmer switch power switch for dispenser models and depress the brew start switch to begin a brew cycle checking the volume of water delivered into decanter Adjust timer to deliver desired amount of water Turn timer dial clockwise to increase volume of water counter clockwise to decrease it On models with...

Страница 4: ...pplicable when not in use Red light in switch indicates when power is on Note The solenoid will not run to replace water in tank that is drawn off from the faucet when the lower warmer switch or power switch for dispenser models is in the OFF position However when the brew cycle is again initiated the tank will fill before cycle begins to prevent a short pot 9 To clean brew basket simply remove fr...

Страница 5: ... warranty by telephone at 800 556 3926 or by writing to 3650 New Town Blvd Saint Charles MO 63301 2 if requested by Newco shipping the defective equipment prepaid to an authorized Newco service location and 3 receiving prior authorization from Newco that the defective equipment is under warranty THE FOREGOING WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY OTHER WARRANTY WRITTEN OR ORAL EXPRESS OR IMP...

Страница 6: ...s not being heated replace the tank heater B If voltage is not present at the tank heater terminals refer to Step 2 C If incorrect voltage is present at the tank heater terminals check voltage at outlet 2 A If voltage is present on the incoming terminal of the hi limit thermostat but not on the outgoing terminal replace the hi limit thermostat B Check voltage between black and white wire on the re...

Страница 7: ...ead 1 Insert correct filter into brew basket 2 Adjust thermostat control knob to obtain correct water temperature 3 Refer to DRIPPING Step 1 4 Filter should be centered in brew basket and coffee bed should be level 5 Install sprayhead SOLENOID CHATTER OR HOWLING 1 Brewer connected to hot water line 2 Vibration 3 High water pressure 4 Water hammer 5 60 Cycle vibration 1 Incoming water line 2 If bre...

Страница 8: ...nual P N 108054 PDS Flow Control Supplemental Information The PDS flow control system is the result of many years of engineering effort to create a flow control valve that would be accurate over a wide range of water pressures as well as maintain its volume setting for many years within the harsh water environment that coffee brewing equipment must operate The valve has been designed to allow for ...

Страница 9: ...y 8d 103936 Adapter 1 8 NPT Fem x 750 O Ring 2 110580 Retainer Outlet Fittings 9 110219 O Ring 625 ID x 750 OD 3 110218 O Ring 375 ID x 500 OD 10 110213 O Ring 562 ID x 750 OD 4a 110220 Adapter 1 4 FL x 500 O Ring 11 110117 Sleeve Ceramic 4b 110108 Plug 500 O Ring 12 110116 Piston Ceramic 4c 110212 Adapter 1 8 NPT x 500 O Ring 13a 110101 Spring Low Flow Valve 4d 110111 Adapter 3 8 Stem x 500 O Rin...

Страница 10: ...pending on its current position Multiple techniques may be used to raise or lower the brew head so use the one that works best for you To RAISE the brew head Grasp the outer column M from behind with one arm while holding the base O in position with the other Raise the brewer to the appropriate height for your dispenser and brewbasket combination The brew head may also be raised by lifting against...

Страница 11: ...PAGE 11 Telescoping Brewer Chasis Diagrams Telescoping Brewer 120 V Wiring Diagram ...

Страница 12: ...PAGE 12 WIRING DIAGRAMS ...

Страница 13: ...PAGE 13 Wiring Continued Thermal Brewer Shown With Autoarm 240V 120V Miscellaneous Figures Valve Section View Micro Switch Section View ...

Отзывы: