![Newall DP900 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/newall/dp900/dp900_manual_1678727015.webp)
12
Setup mode
Zero App. Tolerance
. This is similar to the zero approach tolerance for
the linear mode, except that the setting is in angular mode. The default
value is 0.
You should save the changes that you make in the Setup mode using
Save and Exit.
The options for each menu item are displayed on the soft key label. You
have to press the correct soft key for the required settings.
Machine model
You use this to set the DRO to be Mill specific or Lathe specific, by
selecting mill or lathe using the appropriate soft key.
Auxiliary setup
You use this to set the parameters required for Auxiliary Input/Output
functions. See page 38 for details on using the auxiliary port.
Set factory settings
You use this to set all the DRO parameters to their factory defaults.
This option clears all the programmed data including programs, SDM jobs
and segmented scale compensation.
To return to the factory defaults:
1.
Press .
2.
Press
to confirm that you want to return to the factory default
settings.
If you decide that you don’t want to return to the factory default
settings, press
.
The default setup settings are:
Applying compensation
You configure any compensation values in the Calibrate Axis setting.
Performing a Factory Reset clears any calculated compensation values
and the unit reverts to no compensation.
When you are measuring the values for compensating an axis, you must
ensure that you do not include the diameter of the probe or tool.
Error descriptions
Accuracy problems with machined parts may be caused by machine error,
DRO system error, or a combination of both. The first step in determining
No. of Axis
4
Sleep Mode Time
5
Key Beep Enable
on
Zero App. Beep En.
on
Zero App. Tolerance
0.025mm
Machine Model
Mill
Axis Direction
left
Axis Mode
rad
Zero App. Distance
1.000mm
Apply Compensation
none
Содержание DP900