![Newall DP900 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/newall/dp900/dp900_manual_1678727012.webp)
9
Setup mode
Setup m ode
This chapter describes how to setup the DP900.
Use the right navigation key to scroll through the soft keys until the Setup
soft key (
) appears on the screen. Press the soft key to enter Setup
mode. This is a protected mode, so you need to enter a password to enter
it.
PASSWORD 1 5 9 7 4
. Enter the number and then press the
[
enter
] key.
The Setup mode screen is displayed.
You navigate to the different fields using the up and down navigation keys.
The soft key labels display the options that you can select for each field.
You select a particular option by pressing the appropriate soft key.
General settings
No. of axis
You use this to set the total number of axes that you need to configure.
Select 2, 3 or 4 by pressing the appropriate soft key.
Sleep mode time (min)
You use this to define the Sleep Time Interval in minutes (5 to 120). Enter
the required time using the numeric keypad.
Key beep enable
You use this to enable or disable the keyboard beep. Select on or off by
pressing the appropriate soft key.
Zero app. beep en
You use this to enable or disable the Zero Approach Beep. Select on or off
by pressing the appropriate soft key.
When you enable the Zero Approach Beep, bars appear under the axis
numbers to clearly indicate the direction and relative position of the axis to
zero. As the beep starts the bars start to shrink towards the centre. The
bars disappear when the zero position is reached. The Zero Approach
Beep only beeps when you are within the set approach distance.
The beep rate gets faster as the zero position is approached. The beep is
only for the fastest moving axis.
Some functions like Preset have zero-approach always enabled.
Zero app. tolerance
You use this to set a tolerance value for the Zero Value in Zero approach
modes. Enter the required tolerance using the numeric keypad.
The value that you enter corresponds to the distance from zero that the
DRO considers to be close enough to zero to be counted as zero, i.e. the
point at which the beep becomes continuous (if enabled and so long as
the axis is moving) and when the zero-approach bars are clear.
Diagnostics
This enters a test mode where you can check the keyboard and any
attached encoders. Select keyboard or encoder by pressing the
appropriate soft key.
KBoard
Pressing {
k board
} shows a screen representing all the available keys.
Pressing a key highlights its position on the screen. To exit this test mode
press the [
ce
] key twice.
Encoder
Pressing {
encoder
} shows a screen with all the available axes displayed.
Here you can see the Axis, Count, Pitch, Type and Reference.
Содержание DP900
Страница 1: ...Digital Readout Display DP900 Manual ...