9. Grill and control panel lights
not working
Unit not connected to power.
Plug transformer cord into power box (from working GFI protected
outlet).
Faulty transformer.
Check transformer output – should be 12VAC. Replace if required.
Terminals on switch or circuit board are corroded or loose.
Clean connections and ensure connectors are pushed together firmly.
Access to circuit board is under electrical cover on left side of cabinet.
10. Burner goes out
Location of grill
High wind and wind directly on the back of the grill can cause blow-
outs. Locate the grill towards the prevailing wind.
Check flame
Follow steps outlined in Step 8. of troubleshooting
Burners installed incorrectly
Correctly-installed burners should be seated firmly and level with no
side-to-side movement.
11. Burner goes out when set to
low
Lack of gas.
Check gas level in propane cylinder. Check main shut-off valve is open.
Supply hose is pinched.
Reposition supply hose as necessary.
Dirty or clogged orifice. Spider webs or other matter in venturi
tube.
Clean burner orifice . Clean out venturi tube.
Propane regulator in “low flow” state.
All gas grill valves must be in the off position when the tank valve is
turned on. Turn tank on slowly to allow pressure to equalize. See light-
ing instructions.
12. Rotisserie won’t light
No power to ignition
See Step 10.
Burner won’t light
Refer to steps outlined in Step 12 & 13. of troubleshooting
13. Rotisserie lights and goes
out immediately upon control
knob release.
Continue holding safety valve button in depressed position until
burner remains lit when released. Continue holding safety valve button
in depressed position until
burner remains lit when released.