29
Leak Testing Instructions
Fixing a Gas Leak
• Shut off the gas supply.
• Turn all side burner controls to the “ON” position to purge the side burner of any gas build-up,
then turn the controls back “OFF”.
• Wash off the soapy solution with cold water and dry.
• Tighten the loose joint, or replace the faulty part with manufacturer-recommended replacement
parts.
• DO NOT attempt to repair the Propane gas cylinder valve if it is damaged. The only way to safely
resolve a damaged cylinder is to REPLACE IT.
• Repeat the leak test to ensure that no leaks are present.
• If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the
side burner inspected by a certified gas installer or dealer. Do not use the side burner until the
leak has been corrected.