9

3.  

SMS INPUT CONFIGURATION

 

 
Name cell: 

SMSINPUTCONFIG

  

Number field cell: 

0000000000000000

   

Comment:  
1st number =   SMS about Input No1   
2nd number =  SMS about Input No2  
3rd number =   SMS about Input No3 
4th number =   SMS about Input No4 
5th number =   SMS about Input No5

 

6th number =   SMS about Input No6 
7th number =   SMS about Input No7 
8tht number =  SMS about Input No8 
9th number =   SMS about Input No9 
10th number = SMS about Input No10 
11th number = SMS about Input No11 
12th number = SMS about Input No12 
13th number = SMS about Input No13 
14th number = SMS about Input No14 
15th number = SMS about Input No15 
16th number = SMS about Input No16 
  
    When Input is triggered, controller will send SMS to Admin number 
"0" = 

deny

. "1" = 

send SMS on connection and disconnection

, "2" = 

send SMS on connection 

NO,

 "3" = 

send SMS disconnect NC ,    

Alarm mode settings

- “4”=Full control Inputs 

(doors, windows, motion sensors), “5”= external perimeter control beams

 

 

4.  

ENGINEER SERVICE NUMBER 

 
Name cell: 

SERVICE  

Number field cell

:+353863310929 

 
Comment: 
Telephone number Service engineer :( 

can only do remote system programming

)  

 * By default is Manufacturer 353863310929   but you can change it to your service 
engineer number 
 

5.

 

 

CONFIGURATION TIME INTERVALS

  

 
Name cell: 

TIMECONFIG

  

Number field cell:

 

15251001 

 

 
Comment:  
1st and 2nd number = 

Intercom dial time to Admin number in sec. (01-99sec)  

3rd and 4th number = 

talk time with a door intercom when the call has been answered in sec. 

(01-99sec)

  

5th number = 

Output

 

relay off delay in sec (1-9) on short call relay control mode  

6th number = 

Cal credit balance checking in hours. (0-9h) (0-do not check)

  

7th and 8th number = 

Siren working time in alarm mode (01-99sec), Unused in Gate 

Intercom/Opener mode.   

Содержание GSM-x31-3bi

Страница 1: ...al GSM Intercom Opener forVIDEX FARFISA intercoms Model GSM x31 3bi New World Security 36 Esker Meadow Green Lucan Co Dublin IRELAND Ph 353863310929 tech support gsmalarms eircom net www new world sec...

Страница 2: ...inform the owner about the visitor at the gate The ADMIN can answer the call and speak to the visitor and open the gate with one of the buttons of his phone if he wishes to let the guest in Next way t...

Страница 3: ...3 INSTALLATION FARFISA INTERCOM...

Страница 4: ...4 VIDEX INTERCOM...

Страница 5: ...ptoMOSFET Relay Output 60VDC 0 1A 22 23 R3 OptoMOSFET Relay Output 60VDC 0 1A 24 25 R4 OptoMOSFET Relay Output 60VDC 0 1A Note An antenna must always be connected Always route the GSM cable away from...

Страница 6: ...and text alerts Details of how to do this can be found on the SIM card provider s web site or by calling their customer services Please use one of the following SIM card providers Vodafone TMobile O2...

Страница 7: ...NFIG get INFO SMS SMSCONFIG Text message configuration see 2 On User manual 000000 SMSINPUTCONFIG Inputs configuration to send text messages when Inputs are triggered see 3 On User manual 000000000000...

Страница 8: ...e not use in Intercom mode 2 SYSTEM SMS CONFIGURATION Name cell SMSCONFIG Number field cell 010010 Comment 1st number SMS about power On Off 0 deny 1 allow 2nd number sending SMS to Administrator ADMI...

Страница 9: ...tion 2 send SMS on connection NO 3 send SMS disconnect NC Alarm mode settings 4 Full control Inputs doors windows motion sensors 5 external perimeter control beams 4 ENGINEER SERVICE NUMBER Name cell...

Страница 10: ...checked if the correct balance check string has previously been stored using SDL code 7 ADMIN AND 3 MAIN USER NUMBERS Name cell ADMIN 1 Number field cell 4400000000000 Comment Administrator phone numb...

Страница 11: ...INFO Example INFO Response SMS Voltage13 8V Network 72 Temper 24 c R1 ON R2 OFF R3 OFF R4 ON Getting information from the operator s account and other information Format SMS query CREDITS request for...

Страница 12: ...re SMS text for Input1 disconnect TXT I1OFF Normal temperature SMS text for Input8 connect TXT I8ON Alarm Door OPEN SMS text for Input1 disconnect TXT I8OFF Alarm message 1 OFF SERVICE Replace the con...

Страница 13: ...calling number and if the number is in the list you have prepared it will reject the call and switch On Relay The GSM system doesn t answer the call it simply checks the caller ID Your network must s...

Страница 14: ...14 Manufacturer www New World Security com 2011...