SERVICE Query content configuration of cells:  

  

Format SMS query:

                      < name > <?>   

Example:                                      

WORKCONFIG ?  

Example:                                      

SMSCONFIG ?

  

Example:                                      

SMSINPUTCONFIG ?

  

Example:                                      

TIMECONFIG ?  

Format SMS:

                                < name > < <:> cell data >  

Example:                                     

WORKCONFIG:0001

  

Example:                                     

SMSCONFIG:00101

  

Example:                                     

SMSINPUTCONFIG:0000110101000000

  

Example:                                     

TIMECONFIG:152512

  

 
  
 

Controller INPUT name settings

 

If alarm Input is NC and disconnected loop, controller send alarm SMS with text which you 
can change by your request: 
 

Format SMS to setup text:

    <TXT> > < Input number><:><new text max20   

Example:  
SMS text for Input1 connect           TXT I1ON: Alarm temperature!  
SMS text for Input1 disconnect      TXT I1OFF: Normal temperature 
 SMS text for Input8 connect          TXT I8ON: Alarm! Door OPEN! 
 SMS text for Input1 disconnect     TXT I8OFF:Alarm message 1 OFF    
 
 

SERVICE Replace the contents of the configuration:  

 

(to replace just edit it and send SMS , came in response to a query)  

Format SMS to replace:

               < name > < <:> cell data >  

Example:                                    

WORKCONFIG :1001

  

Example:                                    

SMSCONFIG :11101

  

Example:                                    

SMSINPUTCONFIG :0101110000000000

  

Example:                                    

TIMECONFIG :152584

  

  
Format response SMS: 

Write config SIM is successful!

  

  
  

SMS about the call to the module is not listed in a Subscriber SIM card

:  

 
If User not from controller address book will call in to the system, controller take dialler 
number and resend to Admin number. 
 

Format SMS:

 The attempt is not authorized 353509631994  

 
 
 
 

Содержание GSM-x31-3bi

Страница 1: ...al GSM Intercom Opener forVIDEX FARFISA intercoms Model GSM x31 3bi New World Security 36 Esker Meadow Green Lucan Co Dublin IRELAND Ph 353863310929 tech support gsmalarms eircom net www new world sec...

Страница 2: ...inform the owner about the visitor at the gate The ADMIN can answer the call and speak to the visitor and open the gate with one of the buttons of his phone if he wishes to let the guest in Next way t...

Страница 3: ...3 INSTALLATION FARFISA INTERCOM...

Страница 4: ...4 VIDEX INTERCOM...

Страница 5: ...ptoMOSFET Relay Output 60VDC 0 1A 22 23 R3 OptoMOSFET Relay Output 60VDC 0 1A 24 25 R4 OptoMOSFET Relay Output 60VDC 0 1A Note An antenna must always be connected Always route the GSM cable away from...

Страница 6: ...and text alerts Details of how to do this can be found on the SIM card provider s web site or by calling their customer services Please use one of the following SIM card providers Vodafone TMobile O2...

Страница 7: ...NFIG get INFO SMS SMSCONFIG Text message configuration see 2 On User manual 000000 SMSINPUTCONFIG Inputs configuration to send text messages when Inputs are triggered see 3 On User manual 000000000000...

Страница 8: ...e not use in Intercom mode 2 SYSTEM SMS CONFIGURATION Name cell SMSCONFIG Number field cell 010010 Comment 1st number SMS about power On Off 0 deny 1 allow 2nd number sending SMS to Administrator ADMI...

Страница 9: ...tion 2 send SMS on connection NO 3 send SMS disconnect NC Alarm mode settings 4 Full control Inputs doors windows motion sensors 5 external perimeter control beams 4 ENGINEER SERVICE NUMBER Name cell...

Страница 10: ...checked if the correct balance check string has previously been stored using SDL code 7 ADMIN AND 3 MAIN USER NUMBERS Name cell ADMIN 1 Number field cell 4400000000000 Comment Administrator phone numb...

Страница 11: ...INFO Example INFO Response SMS Voltage13 8V Network 72 Temper 24 c R1 ON R2 OFF R3 OFF R4 ON Getting information from the operator s account and other information Format SMS query CREDITS request for...

Страница 12: ...re SMS text for Input1 disconnect TXT I1OFF Normal temperature SMS text for Input8 connect TXT I8ON Alarm Door OPEN SMS text for Input1 disconnect TXT I8OFF Alarm message 1 OFF SERVICE Replace the con...

Страница 13: ...calling number and if the number is in the list you have prepared it will reject the call and switch On Relay The GSM system doesn t answer the call it simply checks the caller ID Your network must s...

Страница 14: ...14 Manufacturer www New World Security com 2011...

Отзывы: