DISTRIBUTION SYSTEMS PRIMARY HYDRAULIC POWER SYSTEM
6.
Visible contamination is foreign material that can be
found by sight, touch, or odor. Visible contamination
can cause a sudden failure of components. Exam
ples of visible contamination:
(A)
Particles of metal or dirt in the oil.
(B)
Air in the oil.
(C)
The oil is dark and thick.
(D)
The oil has an odor of burned oil.
(E)
Water in the oil.
NOTE:
The hydrostatic system does not have an external
bypass port. If the filter becomes plugged it bypasses the
filter. Upon completion of cleaning the hydraulic system
replace the hydrostatic system filter.
NOTE:
Use the following procedure for Cleaning the Hy
draulic System.
7.
Prepare the portable filter by doing the following
steps:
(A)
Remove all the hydraulic oil from the inlet and
outlet hoses for the portable filter.
(B)
Remove the filter element from the portable filter.
(C)
Remove all hydraulic oil from the portable filter.
(D)
Clean the inside of the housing for the filter
element.
(E)
Install a new filter element in the portable filter.
8.
Determine whether the contamination is micro
scopic or visible. Refer to:
PRIMARY HYDRAULIC
POWER SYSTEM Decontaminating (A.10.A)
9.
If the contamination is microscopic:
(A)
Check the maintenance schedule for the ma
chine to learn if the hydraulic oil must be changed.
If necessary, change the hydraulic oil. Change the
hydraulic filter.
(B)
Do steps 12 through 41.
10.
If the contamination is visible, do the following steps:
(A)
Change the hydraulic oil and hydraulic filter.
(B)
Do steps 11 through 41.
11.
Check the amount of contamination in the hydraulic
system by doing the following steps:
(A)
Disassemble one cylinder in two different cir
cuits. Check for damage to seals, scoring of the
cylinder wall, etc. Repair the cylinders as necessary.
(B)
If, in your judgment, the damage to the cylinders
was caused by sever contamination and is not the
result of normal wear, it is necessary to remove,
clean and repair all valves, pumps, lines, cylinders,
hydraulic reservoir, etc.
in the hydraulic system.
To clean the lines refer to the following procedure:
TRANSMISSION Hydrostatic Cleaning (C.20.F)
12.
Remove the cap from the reservoir and install the
adapter on the reservoir. Start the vacuum pump.
13.
Connect the vacuum pump to the adapter.
Reser
voir Apply vacuum (A.10.A)
14.
Start the vacuum pump.
15.
The hydraulic reservoir is located at the rear of the
machine. Loosen and remove the drain plug from
the reservoir.
87630288 1 6/6/2007
A.10.A / 28
Содержание Super Boom C185
Страница 5: ...87630288 1 6 6 2007 Find manuals at http best manuals com search s NH 87639288 ...
Страница 6: ...INTRODUCTION 87630288 1 6 6 2007 1 Find manuals at http best manuals com search s NH 87639288 ...
Страница 18: ...REPAIR MANUAL DISTRIBUTION SYSTEMS C185 C190 L180 L185 L190 87630288 1 6 6 2007 A ...
Страница 51: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com ...