INTRODUCTION
14. Disconnect the fittings
(1)
at the brake lines and cap
the fittings. There are two brake lines. A Tee fitting
will be required for the two lines in order to connect
to the hand pump. If a T-fitting is not available, two
pumps must be used.
RAPH12DOZ0094AA
15
15. Connect a hand pump with the capacity to reach and
maintain
22.7 bar
(
330 psi
).
16. Operate the pump until the correct pressure is
reached, and the brakes are released.
17. Check and maintain
22.7 bar
(
330 psi
) minimum in
the brake line when moving the machine. Damage
to the brake system can result if the pressure is re-
duced.
18. Tow the machine the shortest possible distance. Do
not tow the machine over
1.2 km/h
(
0.7 mph
).
47907874 06/10/2015
32