4
This device is not designed for people who is physically or mentally weak (including
children) and who does not have experience and knowledge of heating and cooling
system. Unless it is used under direction and supervision of professional technician, or
has received training on the using of this unit. Children must use it under supervision of
an adult to ensure that they use the unit safely. If power wire is damaged, it must be
replaced by a professional technician to avoid danger.
II. System Specification
1. Specification
Model
NERS-G50Y-B1
NERS-G70Y-B1
NERS-G90Y-B1
Air temperature: 26ºC, inlet / outlet water temperature: 26ºC/28ºC, Humidity 80%
Heating capacity
(
kW
)
1.5
~
5.5
1.5
~
7.2
1.8
~
9.5
Power input
(
kW
)
0.104
~
0.84
0.106
~
1.12
0.124
~
1.46
COP
6.55
~
14.4
6.43
~
14.2
6.5
~
14.5
Boost mode
Heating capacity
(
kW
)
5.5
7.2
9.5
COP
6.55
6.43
6.5
Smart mode
Heating capacity
(
kW
)
4.5
5.8
7.8
COP
7.41
7.53
7.52
Silent mode
Heating capacity
(
kW
)
2.1
2.8
3.5
COP
12.2
12.5
12.2
Air temperature: 15ºC, inlet / outlet water temperature: 26ºC/28ºC,Humidity 70%
Heating capacity
(
kW
)
1.1
~
3.9
1.3
~
5.4
1.5
~
7.9
Power input
(
kW
)
0.138
~
0.75
0.168
~
1.102
0.194
~
1.491
COP
5.2
~
7.97
4.9
~
7.74
5.3
~
7.73
Boost mode
Heating capacity
(
kW
)
3.9
5.4
7.9
COP
5.2
4.9
5.3
Smart mode
Heating capacity
(
kW
)
3.1
4.3
6.1
COP
5.92
5.95
5.95
Silent mode
Heating capacity
(
kW
)
2.2
2.4
2.5
COP
6.95
6.88
6.92
Содержание NERS-G110Y-B1
Страница 11: ...9 Model NERS G110Y B1 NERS G150Y B1 NERS G180Y B1 ...
Страница 16: ...14 NERS G50Y B1 NERS G70Y B1 NERS G90Y B1 NERS G110Y B1 ...
Страница 17: ...15 NERS G150Y B1 NERS G180Y B1 ...
Страница 33: ...31 2 3 2 Account ID Password Login Existing accounts can be logged in directly in the following order 1 2 3 4 ...