21
Ambient Temp. and Coil Temp.
to Start Defrosting
P10
Ambient Temp.to Start
Defrosting
0
℃
~20
℃
(32~68
℉
)
17
℃
(63
℉
)
P11
Working Cycle of EEV
20S~90S
25S
P12
Degree of Superheat in Smart/
Powerful Mode
-5
℃
~10
℃
(-9~20
℉
)
Depends on
Actual Model
P13
Exhaust Temp. for Modifying
EEV
70
℃
~125
℃
(158~257
℉
)
95
℃
(203
℉
)
P14
Opening of EEV during Defrosting
( Set Value*10=Actual Steps)
2~45
Depends on
Actual Model
P15
Min. Steps of EEV
(Set Value*10=Actual Steps)
5~15
10
P16
Working Mode of EEV
0 Manual/1 Auto
1
P17
Manual Steps of EEV
(Set Value*10=Actual Steps)
2~45
35
P18
Superheat Degree in Cooling
Mode
-5
℃
~10
℃
(-9~20
℉
)
Depends on
Actual Model
P19
Reserved
/
/
P20
Working Mode of EEV for Cooling
0=Water Temperature
1=Supercooling
0
P21
Working Mode of Water Pump
When Reaching Target Temperature
Reached
1= Non Stop/2= Stop
3=Intermittent
3
P22
Working Mode of Fan
0=Auto/ 1= Manual
0
P23
Manual Control Speed of Fan
(Set Value*10=Actual Speed)
0-99
(Set Value*10=Actual
Speed)
80(Set
Value*10=Actual
Speed)