background image

 
 

 

© New Eagle        www.neweagle.net          PH: 734.929.4557

 

 

6

 

4. 

 

Data Logging 

The logger utilizes a USB drive and data logging is limited only by the size of the USB. The logger is 
configured to log all data both on CAN1 and CAN2 bus. 

 

1.    After the logger is powered up, the data logging screen is shown on the display (Figure 1). 
2.    Press and hold Button 5 to access the configuration menu (Figure 2). 
3.    Plug in the USB drive, after a few seconds, the logging is started, the screen will display ‘USB Stick 

Inserted’ and ‘Logging Active’. If the screen is still showing ‘USB Not Inserted’ after the USB drive is 
plugged in for more than 10 seconds, then plug in the USB drive again, and wait around 
6 seconds until ‘USB Inserted’ is shown on the screen. 

4.    Press the center ‘Eject’ button to stop the logging session. The user can unplug the USB stick when 

the screen displays ‘Logging INACTIVE’ and ‘USB Stick Ejected’. After unplugging the USB, the screen 
will return to the initial data logging screen (Figure 1).NOTE: THE LOGGER CAN NO LONGER ENSURE 
PROPER FILE CLOSURES AND SOME DATA LOSS MAY OCCUR IF THE USER UNPLUGS THE USB DRIVE 
BEFORE STOPPING THE LOGGING SESSION. 

5. To start a new logging session, repeat step 3 and step 4. 

 

 

Содержание VeeCAN320

Страница 1: ... New Eagle www neweagle net PH 734 929 4557 CONTROL SYSTEM SOLUTIONS New Eagle VeeCAN320 Data Logger User Manual Last Updated 9 14 2016 ...

Страница 2: ... New Eagle www neweagle net PH 734 929 4557 2 Contents 1 Overview 3 2 Kit Contents 3 3 Setup 4 3 1 Connector Pins Primary Connector 5 3 2 Harness 5 4 Data Logging 6 4 1 Log Files 7 4 2 File Layout 7 ...

Страница 3: ...t CAN data logger solution available The logger is capable of logging at rates as low as 1ms supports both 11bit and 29bit messages and can be configured to meet the needs of your environment Continue reading to learn about all of its capabilities 2 Kit Contents The kit includes 1 The New Eagle Data Logger Display with software programmed 2 The New Eagle Data Logger harness Sold separately ...

Страница 4: ... powered on the logging session will be started automatically 6 Press the Stop Logging button to stop the logging session and prepare the USB stick for removal It is important to stop the logging using this button otherwise a key cycle will be required to initiate another logging session The logger has two connectors primary connector and secondary connector primary connector is for data logging s...

Страница 5: ... ISOLATED CAN DATA L 9 Not Used 10 Not Used 11 CAN1L PRIMARY CAN DATA L 12 CAN1H PRIMARY CAN DATA H The CAN2 isolated power supply must be wired separately in order to utilize CAN2 3 2 Harness A harness only for CAN1 channel so far is available which is designed to mate the logger with a CAN bus environment Pin Wire Color Purpose 1 Black GND 2 Red PWR 5 Brown CAN2 not included in the harness so fa...

Страница 6: ... Logging Active If the screen is still showing USB Not Inserted after the USB drive is plugged in for more than 10 seconds then plug in the USB drive again and wait around 6 seconds until USB Inserted is shown on the screen 4 Press the center Eject button to stop the logging session The user can unplug the USB stick when the screen displays Logging INACTIVE and USB Stick Ejected After unplugging t...

Страница 7: ...he raw CAN into engineering units See the Raptor CAN section below Msg type Msg Id Size Data Byte0 to Byte7 Time us 0x0CF00400 1 8 0x00 0x00 0x00 0xCC 0x10 0x00 0x00 0x00 302568000 0x0CF00400 1 8 0x00 0x00 0x00 0x33 0x10 0x00 0x00 0x00 302591000 0x0CF00400 1 8 0x00 0x00 0x00 0x9C 0x0F 0x00 0x00 0x00 302616000 0x0CF00400 1 8 0x00 0x00 0x00 0x07 0x0F 0x00 0x00 0x00 302641000 0x0CF00400 1 8 0x00 0x00...

Страница 8: ...agle s simple tool used for communicating with and monitoring CAN systems using a compatible CAN adaptor Using Raptor CAN with the VeeCAN Data logger gives the user the benefit of converting the raw CAN data into engineering units Please see our product wiki for more information ...

Отзывы: