Страница 1: ...is for the 80ZC cabinet ONLY If you require information on the Model 80 unit that fits inside this cabinet please download the Model 80 manual from the Stove Manuals section of our website Thank you for choosing Buck Stove ...

Страница 2: ...MODEL 80 ZC CABINET INSTALLATION FEATURES INSTALLATION MAINTENANCE PREPARATION OPERATION SAFETY NEW BUCK CORPORATION 1992 NARNOCK HERSEY ...

Страница 3: ...e Setting The Cabinet For Framing tf FRONT o SIDE PANEL INSLlAT ION LAYERS I I 0 TOP PANEL INSllATION CAP I h _ it1 TeP PANEL I KfiA l IKIM I f r P FRONT I LOUVl RS I FRONT 0 xx 0 tx I 1 LLI LLI 1 LzJ Q Q 2 z z 0 8J 8J 0 LLI LLI Q E2 E5 E2 Q f l J f l J V 0 0 L FRONT VIEW SIDE VIEW ...

Страница 4: ...ey parts Be sure to follow chimney instructions for proper clearances to combusti bles and proper air spacing required Chlmnoy Cap 1 pp OvO l ch y pipo A CAUTION Vented Root Flashings are required with certain chimney installa tions Be sure to use exacl roor lIashing as indicated Model 80 2 ...

Страница 5: ...ure to maintain required clearances air spaces to combustible materials It is of utmost importance that these parts be installed only in accor dance with these instructions The Zero Clearance Fireplace Cabinet Hodel ZC80 is designed to facilitate the installation of a BUCK STOVE MODEL 80 ONLY Main tain manufacturer s clearances to combustible from cabinet Normally the installation will be accompli...

Страница 6: ...Use the factory approved rain cap which is approved for the type chimney being installed F Maintain manufacturer s clearances from cabinet G The Fireplace Cabinet is not intended for use in mobile homes H DO NOT build a fire directly inside the Model ZC 80 It is designed solely for housing the BUCK STOVE Hodel 80 SELECTING A CHIMNEY INSTALLATION AND LOCATION There are two basic types of chimney in...

Страница 7: ...ase is an enclosure built specifically to house a chimney The interior of a chase is open from the Hodel ZC 80 to the roof eliminating the need to cut through ceilings and the roof Normally a chase is built outside and against the exterior wall of a home A hole is cut through the wall and the Hodel ZC 80 is located in the bottom of the chase with the front of the unit flush with the interior wall ...

Страница 8: ...our Buck Stove Dealer for assistance with the planning CHIMNEY INSTALLATIONS Position Hodel ZC 80 for chimney installation as follows A Thoroughly clean the area where the unit will be placed B Layout the location on the floor and construct base See Figure 5 C If chimney is to be installed through a ceiling drop a plumbline locate and mark point on ceiling directly over center of Model ZC 80 chimn...

Страница 9: ...nts so install accordingly 1 Before framing combustible floor coverings carpet tiles etc must be removed to outer dimension of unit framing includ ing the 16 x 42 1 2 area for the hearth extension FIGURE 1 A Safety shield for millboard hearth extension Attach safety shield using sheet metal screws WARNING Install the hearth protector only as specified The hearth extension must extend a minimum of ...

Страница 10: ...ame the ZC Cabinet usng 2 x 4 studs or local building code framing Some minor framing restrictions are required A Adjacent side walls must be at least 6 from the outer edge of the Cabinet trim panel B The overall opening dimensions must be at least 47 1 2 Hide and 41 1 2 high C Framing must protrude 2 1 2 to allow for finished wall to come flush with the back of the ZC Cabinet trim panel See Fig u...

Страница 11: ... a minimum of 16 in front of the fireplace opening and must be 47 1 2 wide mini mum CAUTION Refer to chimney manufacturers instructions for assembly and disassembly of chimney parts Be sure to follow chimney instructions for proper clearances to combusti bles and proper air spacing required Doubl H der 1 A Double Header must be used on a load bearing wall This must be done 12 above cabinet Chimney...

Страница 12: ... 7 s S1 f i H tt f Met al Fire Slop NOTE A Double Header must be used on a load bearong all as illustrated in F gure 3 2 4 Studding H f t H A Single Header must be Installed above cabinet Vert cal 2 4 s must be turned flat NOTE Finished wall must be 2 in front of face of Z C Cabinet without hood trim attached WARNING Install the hearth protector only as specified The hearth extension must extend a...

Страница 13: ...tool and crimp the bottom of the inside chimney liner Install pipe to cabinet by pushing down over the starter section of pipe on the ZC Cabinet Maintain a 2 inch minimum clearance Attach sheet metal clips 2 ea to pipe and cabinet top to assure stability WARNING Do not pack required air spaces on top of cabinet or around pipe starter section with insulation or other mate rials 11 ...

Страница 14: ...ROOF CLEARANCE Frame a square opening in roof maintaining the required 2 clearance to combustible materials between the chimney and the framed opening and roofing material INSULATION RADIATION FIRES TOP RADIATION SHIELD Provides proper clearance 2 clearance does not app y Clearance between chimney and enclosing wall 2 ROOF rr ATTIC CEILING ROOM 8 Chimney fits between standard 16 OC joists 12 ...

Страница 15: ...receptacle cover 2 Remove receptacle from mounting box 3 Run No 14 AWG wire directly from house wiring in through the Field Connector in the lower right side of the Cabi net Leave 4 6 inches of wire extending out of the box 4 Tighten Field Connector around wire 5 Wire receptacle black white and ground and resecure to mounting box 6 Replace receptacle cover FIGURE 9 GROUND HOUSE WIRING TO STUD POI ...

Страница 16: ...om front of the Cabinet cannot be blocked Optional Fire Code Sheet Rock A hearth extension must extend to a minimum of 16 in front of the fire place opening The mantel must be posi tioned a minimum of 14 above the top of the trim kit hood Use a non combusti ble millboard having a thermal conductivity of K 0 84 BTUin ft 2HOF or a listed floor protector The millboard or floor protector may be covere...

Страница 17: ...ure that Cabinet has not been damaged during masonry pro cess D Remove protective plastic wrapping from stove E Inspect motor_and associated hardware for damage F Slide the Buck Stove Model 80 into the Cabinet all the way to the back so that the flue exit of stove lines up under stack G Turn stack positioning nuts counter clockwise allowing stack to be lowered Push downward and fit evenly until re...

Страница 18: ...y using 1 screws to secure the trim panels in place I Remove cover plate from Cabinet exposing receptacle Roll up pOHer cord so it will fit inside of cover box Plug in pOHer cord in receptacle Re place cover plate See Figure 10 Cover Plate o Sheet Metal Screws 16 FIGURE 10 ...