background image

2264ALB Limiter / Compressor

Issue 1

 2264 Operation

LIMITING – ATTACK TIME

This unit has a limiting attack time of 4msec.

This slow attack time is used on programme material of moderately 
percussive nature, such as a solo piano.

With this attack time a very narrow dynamic range can be achieved by 

feeding high levels into the limiter while using a low limit level.

A fast attack time is desirable for example, when the unit is used for 
driving a transmitter.

Fast attack times should be used with care when recording.

The point at which the limiting threshold occurs can be varied b4 
dBm and +15 dBm.

A range of recovery times for the limiting action is provided by the 

LIMIT 

RECOVERY

 control which may be selected according to the nature of the 

programme.

The 

AUTO

 position is used where automatic corrective action is preferred.

This provides a composite control, with  rapid response to isolated peaks 

and a slower recovery after prolonged high levels.

The figure below shows the relationship between input and output levels 
with the 

LIMIT LEVEL

 set at +4 dBm and +12 dBm.

- 7 -

Содержание 2264ALB

Страница 1: ...2264ALB Limiter Compressor User Manual 527 402 Issue 1...

Страница 2: ...info crm fault_report html 2009 2012 AMS Neve Ltd own the copyright of all information and drawings contained in this manual which are not to be copied or reproduced by any means or disclosed in part...

Страница 3: ...ASS Switch 9 LINK 9 Insert Mode 10 DIP switch Settings 10 Configuration Examples 11 Unit Specifications 12 Recall sheets 13 In the unlikely event that this unit should malfunction or develop a fault t...

Страница 4: ...are more precise than those of a 2254 R Also it has a switchable Slow Attack feature for applications such as Bus Compression The 2264A LB Limiter Compressor has been designed for use in sound broadca...

Страница 5: ...on effect takes place Compressor RECovery The outer metal knob a switched attenuator with notched settings from 100ms to 1500 ms controls the recovery time of the Compressor There are also two Auto se...

Страница 6: ...h is in the SA Slow Attack position the attack time of the Compressor section is slowed for applications such as bus compression Whe the switch is not in the SA position the attack time is reverted to...

Страница 7: ...ing a transmitter Fast attack times should be used with care when recording The point at which the limiting threshold occurs can be varied between 4 dBm and 15 dBm A range of recovery times for the li...

Страница 8: ...e range of effects Low ratios operated from a low threshold will preserve the impression of dynamic range while enabling the operator to achieve a significantly better signal to noise ratio when recor...

Страница 9: ...terminated This effect arises because the unit constitutes a buffer amplifier having a high input and low output impedance The limiter compressor may be used as a linear amplifier providing both the L...

Страница 10: ...to the 1073LB User Manual for details on configuring the 1073LB for insert mode 2264A LB configured for Standalone Mode Factory default settings Standalone Mode Factory Default Left switch block Switc...

Страница 11: ...64A LB wired as Insert Signal flow 1073LB 2264A LB 1073LB 2 way insert cable Neve p n NN5749 or 3 way insert cable Neve p n NN5790 with Loopback Plug fitted to S2 socket 1073LB with 1073LB EQ then 226...

Страница 12: ...05 b COMPRESS switched IN ratio 6 1 recovery 800ms output level 9dBm 0 2 c LIMIT switched IN recovery 800ms input level 20dBm threshold 4dBm 0 4 Parameters Limit Threshold Variable from 4dBm to 15dBm...

Страница 13: ...2264ALB Limiter Compressor Issue 1 Recall sheets 13...

Отзывы: