Neve 1073N Скачать руководство пользователя страница 8

1073N Channel Amplifier

Issue 1.4

This applies to both stand-alone and rack/console use.

XLR/Jack combo connection: 

Use the XLR connection for Mic sources 

and the Jack connection for line sources.

Phantom: 

The phantom switch applies phantom power to anything 

connected to the XLR part of the combo input. This only applies to stand-

alone use. When used in a rack or console phantom power will be set on 
the rack/console.

Sleeve:

 For future expansion.

Rack Mount Instructions

 Elevated Operating Ambient- If installed in a closed or multi-unit rack 

assembly, the operating ambient temperature of the rack environment 

may be greater than room ambient. Therefore, consideration should
be given to installing the equipment in an environment compatible with 

the maximum ambient temperature (50 deg C) specified by the 
manufacturer.

 Reduced Air Flow - Installation of the equipment in a rack should be 

such that the amount of air flow required for safe operation of the 
equipment is not compromised.

Mechanical Loading - Mounting of the equipment in the rack should be 

such that a hazardous condition is not achieved due to uneven mechanical 
loading.

Reliable Earthing - Reliable earthing of rack-mounted 

equipment should be maintained. Particular attention should be 
given to supply connections other than direct connections to the 

branch circuit (e.g. use of power strips).

Troubleshooting

No audio at the line output

Check that you’re turning the gain knob in the right direction. Turn it 

clockwise (mic mode) if you’re using the XLR part of the combo connector 
or DI jack input. Turn it anti-clockwise (line mode) if you’re using the jack 

part of the combo connector.

 

If you’re using the 1073N in stand-alone mode check that EXT LVL 

CTRL is set to NO.

- 8 -

Содержание 1073N

Страница 1: ...1073N Channel Amplifier User Manual 527 404 Issue 1 4...

Страница 2: ...m Support http www ams neve com support 2016 AMS Neve Ltd own the copyright of all information and drawings contained in this manual which are not to be copied or reproduced by any means or disclosed...

Страница 3: ...iguring the 1073N for Neve rack or Original BCM10 6 Configuring the 1073N for Neve 45 series consoles including the new 2016 BCM10 6 Rear Panel Controls Connectors Quick Configuration Guide 6 Rear Pan...

Страница 4: ...to YES This terminates the high pass filter correctly where an external level control is not present u Connect the supplied 48V power adaptor PS10500 to the 48V input u Connect your mic line or DI inp...

Страница 5: ...ate confirming that phantom power is supplied u The mains switch on the rear panel of the 3U rack unit is non illuminating Output Level Control u Each channel has an independent Output Level Control T...

Страница 6: ...ginal BCM10 the rear panel input and output connections power switch and phantom power controls are not used the following configuration should be used for the remaining controls u Set EXT LVL CTRL sw...

Страница 7: ...henol back connector so the level can be controlled by an external volume control or an external fader If this is set to YES in stand alone mode there will be no audio present at the line output When...

Страница 8: ...mperature 50 deg C specified by the manufacturer u Reduced Air Flow Installation of the equipment in a rack should be such that the amount of air flow required for safe operation of the equipment is n...

Страница 9: ...k Units 3U 5U Rated Voltage 100 230V AC 100 230V AC Rated Frequency 50 60 Hz 50 60Hz Rated Current 0 5A Max 0 8A Max Primary Protection Fuse Operating Voltage 100 230V AC 100 230V AC Fuse Rating and T...

Страница 10: ...ou wish to move the rack from one location to another for example shipping to another studio location or returning the rack to a repair centre for servicing please remove all installed modules from th...

Страница 11: ...1073N Channel Amplifier Issue 1 4 Amphenol Back Connector Details Standalone 1073N Module Wiring to 18 way Free Plug 11...

Страница 12: ...d Output Specifications u Microphone Input Input Impedance 300W or 1200W gain 80dB to 20dB in 5dB steps u Line Input Input Impedance 10kW bridging gain 20dB to 10dB in 5dB steps Both inputs are transf...

Страница 13: ...1073N Channel Amplifier Issue 1 4 RecallSheet 1073NVerticalModule 13...

Страница 14: ...1073N Channel Amplifier Issue 1 4 Recall Sheet 1073N Horizontal Module 14...

Отзывы: