Draft. Nr.: BDA 380
Update: 15.09.2015
Data subject to change without prior notice. 2015 NEUTRIK . ALL RIGHTS RESERVED. NEUTRIK are registered trademark.
I
I
®
®
©
ASSEMBLY INSTRUCTION
powerCON TRUE1
I
R
Torque Value 0.7 Nm
5.
Torque Value 2.0Nm
PRESS FIRMLY
Torx size
T8
1.
2.
4.
Wrench size
13 mm
6.
3.
Important:
Push and turn simultaneously.
FOR DISASSEMBLY - OPEN TWIST LOCK!
1.
Press with screw driver to unlock
2.
Turn bushing while still press the locking.
1.
2.
CAUTION
To ensure protection
category, do not expose
the connection to
bending forces (e.g. do
not attach loads to the
cable, no free-dangling
cable windings etc.).
LIECHTENSTEIN
20
250
P S
E
JET
FORCE
G
E
F
www.neutrik.com
NEUTRIK AG
LI
T:
+423
/
237
24
24
F:
+423
/
232 53 93
NEUTRIK USA Inc.
USA
T:
+1
704
/
972 3050
F:
+1
704
/
438 9202
(
)
NEUTRIK UK Ltd.
UK
T:
+44
1983
/
811
441
F:
+44
1983
/
811
439
NEUTRIK
Vertriebs
GmbH
DE
/
NL
/
AT/DK T:
+49
8131
/
280
890
F:
+49
8131
/
280
830
NEUTRIK France
FR
T:
+33 1
/
4131 6750
F:
+33 1
/
4131 0511
NEUTRIK Tokyo Ltd.
JP
T:
+81 3
/
3663 4733
F:
+81 3
/
3663 4796
NEUTRIK Hong Kong Ltd.
HK
T:
+852
/
2687 6055
F:
+852
/
2687 6052
NEUTRIK India Pvt. Ltd.
IND
T:
+91
/
982 05 43 424
F:
+91
/
22 26163 540
Important:
Align rubber key
and latch.
Insert the wires into the terminals and fasten the
screw with Torx size T8.
Wiring
VDE
UL
L
brown
black
Þ
N
blue
white
Þ
green
/
yellow
green
Þ
Slide the chuck onto the insert (1) and then both
together into housing (2).
Important: Align the chuck and insert by
positioning the nose into the keyway.
Slide the bushing up the cable and tighten it with
the tool as shown.
Important:
Yellow O-ring to hide to achieve IP
protection (6).
(Tool available: Art. No. HTAC)